Three dimensional (3D) endobronchial brachytherapy
planning with computed tomography (CT) guidance may
help the accurate localization of the target where the
prescription dose was administered in patients with lung
cancer. In this article, we present a 60-year-old male case of
T3N3 non-small cell lung cancer patient who was previously
treated with chemotherapy and external beam radiotherapy
and was admitted with the complaints of hemoptysis,
hoarseness and dyspnea. In his first bronchoscopy, argon
laser coagulation was used due to massive hemorrhage
of endobronchial lesion obstructed almost totally the left
upper and lower lobes. The 3-fraction of 5Gy/week high
dose rate endobronchial brachytherapy was applied with
CT guided 3 dimensional planning and the atelectasis was
opened, while hemoptysis and dyspnea were improved.