He had been followed up in the pediatric cardiology outpatient clinic periodically up until the age of four when an echocardiographic examination revealed enlargement and hypertrophy of the right ventricle and a pressure gradient of 50 mmHg in the left pulmonary artery. The right ventricular enlargement and hypertrophy were thought to be caused by pulmonary stenosis, so it was decided to perform angiographic visualization of the pulmonary artery and its branches along with balloon angioplasty of the peripheral pulmonary artery. In addition, if necessary, a stent would be implanted following angioplasty.
The procedure was conducted under general anesthesia. Since the hepatic enzyme levels were high, fentanyl (1 μg/kg) and propofol (2 mg/kg) were used during the induction of general anesthesia in which a laryngeal mask was used and 1-2% sevoflurane was given. The pressures were measured via right-sided cardiac catheterization using the right femoral vein. The right ventricle pressure was 54/5 mmHg, the pressure before pulmonary stenosis was 53/25 with a mean of 35 mmHg, and the pressure after stenosis was 16/12 with a mean of 14 mmHg (pressure gradient at the level of stenosis of 37 mmHg). A 23 mm long segment of stenosis with a diameter of 2.1 mm was observed, and the diameter of the normal peripheral pulmonary arterial segment after stenosis measured 3.7 mm.
Stenosis was not decreased after balloon angioplasty procedure was performed using the Tyshak II balloon dilatation catheter (B. Braun Interventional Systems, Inc., Bethlehem, PA, USA). Therefore, the angioplasty procedure was applied to the left pulmonary artery stenosis twice via a cutting balloon. Furthermore, we used a long sheath to prevent the damage that could have been done to the surrounding structures. After the procedure, the stenotic segment had dilated to 2.7 mm in the angiographic examination, and the 24 mm Palmaz® Genesis® balloon-expandable stent [Cordis Europe, Middle East, Africa (EMEA), a division of Johnson & Johnson Medical N.V./S.A, Waterloo, Belgium) was later implanted in the stenotic area using a 7 mm x 25 mm balloon.
After the stenting procedure, the stenotic pulmonary artery segment was dilated to 3.7 mm, and the gradient at this level regressed to 14 mmHg (Figure 1). No complications developed during or after the procedure, and the 18-month echocardiographic examination revealed no significant pressure gradient across the stent.
Either the JAG1 mutation or a deletion in this locus exists in most patients with AGS; however, no correlation was found between the phenotype of the cardiovascular anomaly and the location of the JAG1 mutation in the study by McElhinney et al.[3] Nevertheless, due to the high incidence of congenital cardiac defect in patients with AGS, a cardiological examination should be performed.[5]
Surgical repair of the peripheral pulmonary artery stenosis is difficult and often unsuccessful. On the other hand, balloon angioplasty, which has been performed since the beginning of the 1980s, is safe and reliable.[6] The indications for balloon dilatation and stent implantation in peripheral pulmonary artery stenosis have been defined in the literature.[6] For our case, the indications for balloon dilatation were peripheral pulmonary artery stenosis with a segmental structure and right ventricular hypertrophy, and stent therapy was indicated by the continuation of relative stenosis after the cutting balloon angioplasty.
Cutting balloon angioplasty is preferred peripheral pulmonary artery stenosis resistant to dilatation with conventional angioplasty. A cutting balloon is a device with three or four microtomes mounted longitudinally on its surface. During the dilatation procedure, the device is guided toward the surgical incision in the media of vessels, which may cause the dilatation of the interincisional tissue. However, the reliability and safety of cutting balloon angioplasty have been verified in experimental animal models.[6]
This type of angioplasty may also have the advantage of creating controlled cuts instead of uncontrolled tears,[6] and it is effective for resistant peripheral pulmonary artery stenosis when conventional balloon angioplasty was unsuccessful.[7,8]
Both balloon angioplasty and stent implantation are safe interventional treatments. However, Baerlocher et al.[9] reported an increase in mortality due to the high balloon-to-vessel ratio after the application of balloon angioplasty, particularly in infants. Even though stents appear to be a safer and more permanent alternative treatment, other additional interventions may be required afterwards. The stent area should also be enlarged surgically in cases in which maximal diameters have been reached.
A successful procedure is defined as achieving a 50% increase in the diameter and a 20% decrease in the ratio of right ventricular systolic pressure to aortic systolic pressure after the procedure.[7] According to this description, our cutting balloon angioplasty procedure was partially successful, but the subsequent stent implantation procedure was a complete success.
Peripheral pulmonary artery stenosis, which is seen in more than half of all AGS cases, may affect the quality of life (QOL) of patients and therefore must be treated. When the difficulty and failure of surgical procedures are taken into consideration, balloon angioplasty and stent implantation are safe and effective alternatives. However, further studies with long-term follow-up are required to confirm the safety of cutting balloon angioplasty.
Declaration of conflicting interests
The authors declared no conflicts of interest with
respect to the authorship and/or publication of this
article.
Funding
The authors received no financial support for the
research and/or authorship of this article.
1) Turnpenny PD, Ellard S. Alagille syndrome:
pathogenesis, diagnosis and management. Eur J Hum
Genet 2012;20:251-7.
2) Watson GH, Miller V. Arteriohepatic dysplasia: familial
pulmonary arterial stenosis with neonatal liver disease. Arch
Dis Child 1973;48:459-66.
3) McElhinney DB, Krantz ID, Bason L, Piccoli DA, Emerick
KM, Spinner NB, et al. Analysis of cardiovascular phenotype
and genotype-phenotype correlation in individuals with
a JAG1 mutation and/or Alagille syndrome. Circulation
2002;106:2567-74.
4) Emerick KM, Rand EB, Goldmuntz E, Krantz ID, Spinner
NB, Piccoli DA. Features of Alagille syndrome in 92
patients: frequency and relation to prognosis. Hepatology
1999;29:822-9.
5) Saidi AS, Kovalchin JP, Fisher DJ, Ferry GD, Grifka RG.
Balloon pulmonary valvuloplasty and stent implantation. For
peripheral pulmonary artery stenosis in Alagille syndrome.
Tex Heart Inst J 1998;25:79-82.
6) Trivedi KR, Benson LN. Interventional strategies in the
management of peripheral pulmonary artery stenosis. J
Interv Cardiol 2003;16:171-88.
7) Sugiyama H, Veldtman GR, Norgard G, Lee KJ, Chaturvedi
R, Benson LN. Bladed balloon angioplasty for peripheral
pulmonary artery stenosis. Catheter Cardiovasc Interv
2004;62:71-7.