A 63-year-old male presented to the emergency department with a history of a sudden onset of shortness of breath and chest pain. The patient had prior coronary angiography in an external center due to acute coronary syndrome five years prior to admission. Due to severe left main coronary artery (LMCA) stenosis, a drug-eluting stent from the LMCA to the left anterior descending artery was implanted. Transthoracic echocardiography illustrated a dilated left ventricle (LV) with an estimated ejection fraction of 32% and moderate-to-severe mitral regurgitation and tachycardia. The patient was directly transferred for coronary angiography. During the procedure, the LMCA could not be cannulated with a Judkins left 4 (JL4) catheter and, therefore, a JL3.5 was used, and only selective images could be taken. Coronary angiography revealed multivessel disease, and coronary artery bypass grafting (CABG) was decided.

Before the operation, transesophageal echocardiography (TEE) was performed to evaluate mitral valve disease. From the aortic valve window, a short-axis view was obtained, and a hyperechoic, fixated, smooth bordered lesion was detected on the left coronary cusp (Figure 1a, Video 1). Visualization of the lesion in the three-dimensional TEE plane from different angles revealed that the lesion was located in sinus of Valsalva. Cusp perforation did not appear in color Doppler imaging (Figure 1b, Video 2) The patient's current and former coronary angiographies were revisited and the LMCA stent was found to protrude into the aorta in both images (Figure 2, Video 3). The Heart Team decided not to remove the stent, since the protruding stent was relatively far from the aortic valve and the part of the stent in LMCA was long and the protruded part of the stent was decided to be measured and re-evaluated using coronary computed tomography prior to operation. Despite having been informed of all the risks, the patient refused CABG and left the hospital after signing the treatment refusal form.

Figure 1: (a) Short axis view of transesophageal echocardiography showing a hyperechoic, fixated, smooth bordered lesion on the left coronary cusp. (b) Transesophageal echocardiographic mid-esophageal aortic valve long-axis view showing fixated, the smooth bordered lesion located in sinus of Valsalva.
LCC: Left coronary cusp; RCC: Right coronary cusp; NCC: Non-coronary cusp; LV: Left ventricle.

Figure 2: (a, b) Left coronary angiogram showing the protruded left main stent into the aorta.
LMCA: Left main coronary artery.

Video: Video showing minimally invasive total arterial off-pump coronary revascularization.

Video: Video showing minimally invasive total arterial off-pump coronary revascularization.

Video: Video showing minimally invasive total arterial off-pump coronary revascularization.

The American College of Cardiology (ACC) and European Society of Cardiology (ESC) guidelines recommend CABG for patients with Class IB indications in stable LMCA disease that has a favorable coronary anatomy and low surgical mortality.[1] Dislodgement of a stent during or after percutaneous coronary intervention is a rare complication with an incidence ranging from 0.32 to 8%.[2] Stent restenosis, stent rupture, thrombosis, and malpositioning are the most common complications during and after percutaneous interventions for the LMCA.[3] The treatment approach for a malpositioned stent is still unclear. A malpositioned LMCA stent can be treated either surgically or conservatively. Gunes et al.[4] presented a case of a successful removal of a malpositioned right coronary artery stent with a guidewire. Also, in two cases presented by Sechi et al.,[3] malpositioned and thrombosed LMCA stents were surgically treated. Our case was fortunate enough not to have such complications after stent placement. Although there are different approaches to stent dislodgement treatment, our rare complication case with the silent course demonstrated the importance of detailed echocardiography and multi-modal imaging in the preoperative examination.

Declaration of conflicting interests
The authors declared no conflicts of interest with respect to the authorship and/or publication of this article.

Funding
The authors received no financial support for the research and/or authorship of this article.