Methods: We performed right axillary artery cannulation in 82 patients (38 males, 44 females; mean age 59.5±10.6 years; range 32 to 85 years) with the ascending aorta or aortic arch pathologies. Preoperative diagnosis was classified as aneurysm of the ascending aorta or aortic arch due to arteriosclerosis or degeneration (n=46, 56.1%), acute type A aortic dissection (n=28, 34.1%), and porcelain aorta (n=6, 7.3%). All of the patients underwent replacement of the ascending aorta and in 21 of these patients, replacement of the ascending aorta was extended to the hemiarch. Five of the patients underwent total aortic arch replacement. A modified Bentall procedure was performed on 52 patients, and supracoronary graft implantation was performed on 30 patients.
Results: According to clinical examination no complications related to axillary artery cannulation, such as brachial plexus injury, axillary artery thrombosis, or local wound infection, were observed. The mean CPB time and aortic cross-clamp time were 190.8±62.0 min and 72.0±21.7 min, respectively.
Conclusion: Postoperatively, five patients died and one patient developed a new stroke. We think that the full-flow CPB performed using axillary cannulation via transpectoral approach with subclavicular incision is a feasible and safe method with acceptable morbidity and mortality.
Despite several advantages of right axillary artery cannulation in surgery of the ascending aorta and aortic arch, problems and complications of this technique are coming to the forefront with increased use.[8,9] Among these are the choice of the cannulation site in the presence of pulselessness or attenuation of the pulse of the right upper limb, the possibility of left cerebral hemisphere hypoperfusion with unilateral perfusion, and axillary artery and brachial plexus injury. There is still some debate about which part of the axillary artery will be safe for cannulation. While some prefer a subclavicular approach, others prefer a transpectoral or subpectoral approach.[4,6,7,10]
Here, we report our preliminary experiences using the transpectoral approach for axillary artery cannulation in aortic dissection or aortic arch pathologies.
Twenty-eight of the operations were performed on an emergency basis and 54 as elective cases. All of the patients underwent replacement of the ascending aorta, and in 21 of those patients, the ascending aorta replacement was extended to the hemiarch. In addition, five patients underwent total arch replacement. Modified Bentall procedure was performed in 52 patients, and supracoronary graft implantation was performed in 30 patients. The concomitant procedure was coronary artery bypass grafting in 16 patients (19.5%). Operative characteristics are presented in table 1.
Table 1: Patients undergoing axillary artery cannulation for cardiopulmonary bypass
Surgical technique
The patient was placed in the standard supine position.
For better exposure of the right axillary artery, the arm
was positioned near the body with the hand down to the
side and the elbow slightly flexed. The patient's upper
body was elevated 20 degrees and tilted toward the left,
so that the skin of the overlying infraclavicular fossa
was nearly horizontal. Arterial pressure was routinely
measured with a left artery cannula.
Before the median sternotomy, a 6 to 8 cm transverse skin incision was made approximately 1 cm below the middle and lateral part of the right clavicle (deltopectoral groove). Following the direction of its fibers, the pectoralis major muscle was separated, and the underlying pectoralis minor muscle was retracted laterally (Figure 1). The axillary artery was identified by palpation and then gently mobilized by sharp dissection without touching the medial and lateral brachial plexus cords posterior to the artery. The artery was then controlled with loops of silicone elastomer tape. After administration of heparin, an umbilical tape with a tourniquet was passed around the axillary artery, and the proximal and distal part of the exposed segment was clamped with vascular clamps. After performing a transverse incision, the axillary artery was cannulated directly with an 18 F, 20 F, or 22 F (DLP, Medtronic, Inc, Minneapolis, MN, USA) cannula which was advanced 3-4 cm into the artery while the proximal clamp was removed. The tourniquet was secured over the artery and the cannula (Figure 2). After arterial cannulation, a median sternotomy was performed, and a two-stage cannula was used in all patients for right atrial venous cannulation.
Figure 1: Transpectoral approach for axillary artery cannulation.
Cardiopulmonary bypass was established and an arterial flow of 2.8 L/min/m2 w as e asily o btained at normothermia. After full flow was achieved without observable problems, cooling was started. The mid-ascending aorta was clamped and coldblood cardioplegia was administered in antegrade and retrograde fashion for myocardial preservation. Proximal aortic reconstruction was then initiated. Once this was completed, the innominate and left common carotid arteries were exposed. When rectal temperature reached 24-26 °C, CPB flow was decreased to a volume flow of 10 mL/kg/min, and the innominate and left common carotid arteries were clamped so that unilateral antegrade cerebral perfusion was accomplished. The table was placed in the Trendelenburg position, and the aortic cross-clamp was removed. The arch was inspected from the inside. All arch reconstruction and distal anastomoses were performed with an open aortic anastomotic technique while low-flow perfusion through the right axillary artery was continued. When the distal repair was completed, the ascending aortic graft was cross-clamped, and the innominate and left common carotid arterial clamps were removed, thereby starting systemic circulation. Flow through the axillary artery was gradually increased, and warming was started. Hot shot cardioplegia was administered prior to removing the aortic cross-clamp.
Possible reasons for changes in the axillary arterial cannulation site include an insufficient distance from the cannula to the innominate artery wall, stenosis of the vessel, small vessel diameter or arterial kinking after cannula introduction, and arterial wall damage after axillary artery cannulation.[12,13] In t his study, we did not experience any of these. We regard it as very important that forced cannulation is absolutely avoided. The main complications of axillary artery cannulation as described in the literature are brachial plexus injury and axillary artery thrombosis, none of which occurred in our series.[8,14]
A known contraindication regarding the use of the axillary artery for cannulation is severe atherosclerotic disease of this artery leading to dissection of the cannulation site.[15] However, these vessels are rarely involved in the atherosclerotic process.[9] In all our successful cases, CPB flows of 2.8 mL/m2 per minute were easily obtained.
In the presence of aortic dissection or iliofemoral disease, arterial perfusion through the right axillary artery is a safe and effective means of providing sufficient arterial inflow during CPB. However, in type A aortic dissection surgery, the choice of arterial inflow for CPB is influenced by many factors and depends on the surgeon's experience. Femoral arterial cannulation, a common method of cannulation for CPB, has some drawbacks. The complex anatomy of the false lumen may exclude peripheral vessels making femoral arteries unsuitable sites. Inappropriate perfusion of the false lumen during CPB may be catastrophic. It could lead to ischemia of the brain and spinal cord as well as aortic wall rupture. Thus far, we have not experienced any major vascular complications when using axillary artery perfusion.
In summary, we feel that full-flow CPB through axillary cannulation via the transpectoral approach with subclavicular incision is a feasible and safe method with acceptable morbidity and mortality.
Declaration of conflicting interests
The authors declared no conflicts of interest with respect
to the authorship and/or publication of this article.
Funding
The authors received no financial support for the
research and/or authorship of this article.
1) Eugene J, Aronow WS, Stemmer EA. Retrograde aortic
dissection during cardiopulmonary bypass. Clin Cardiol
1981;4:356-9.
2) Robicsek F, Guarino RL. Compression of the true lumen
by retrograde perfusion during repair of aortic dissection. J
Cardiovasc Surg (Torino) 1985;26:36-40.
3) Parr GV, Manley NJ, Williams DR, Montesano RM.
Obstruction of the true lumen during retrograde perfusion of
type I aortic dissections: a simplified solution. Ann Thorac
Surg 1980;30:495-8.
4) Schachner T, Vertacnik K, Laufer G, Bonatti J. Axillary
artery cannulation in surgery of the ascending aorta and the
aortic arch. Eur J Cardiothorac Surg 2002;22:445-7.
5) Neri E, Massetti M, Capannini G, Carone E, Tucci E,
Diciolla F, et al. Axillary artery cannulation in type a
aortic dissection operations. J Thorac Cardiovasc Surg
1999;118:324-9.
6) Battaloglu B, Erdil N, Nisanoglu V. Axillary artery perfusion
in acute type A aortic dissection repair. J Card Surg
2008;23:693-6.
7) Strauch JT, Spielvogel D, Lauten A, Lansman SL, McMurtry
K, Bodian CA, et al. Axillary artery cannulation: routine use
in ascending aorta and aortic arch replacement. Ann Thorac
Surg 2004;78:103-8.
8) Sabik JF, Lytle BW, McCarthy PM, Cosgrove DM. Axillary
artery: an alternative site of arterial cannulation for patients
with extensive aortic and peripheral vascular disease. J
Thorac Cardiovasc Surg 1995;109:885-90.
9) Kokotsakit J, Lazopoulos G, Milonakis M, Athanasiadis G,
Romana K, Skouteli E, et al. Right axillary artery cannulation
for surgical management of the hostile ascending aorta. Tex
Heart Inst J 2005;32:189-93.
10) Zattera G, Totaro P, D\'Armini AM, Vigano M. Deltoidopectoralis
approach to axillary vessels for full-flow
cardiopulmonary bypass. Eur J Cardiothorac Surg 2009;
35:913-4.
11) Sabik JF, Nemeh H, Lytle BW, Blackstone EH, Gillinov AM,
Rajeswaran J, et al. Cannulation of the axillary artery
with a side graft reduces morbidity. Ann Thorac Surg
2004;77:1315-20.
12) Schachner T, Nagiller J, Zimmer A, Laufer G, Bonatti J.
Technical problems and complications of axillary artery
cannulation. Eur J Cardiothorac Surg 2005;27:634-7.
13) Miyatake T, Matsui Y, Suto Y, Imamura M, Shiiya N,
Murashita T, et al. A case of intraoperative acute aortic
dissection caused by cannulation into an axillary artery. J
Cardiovasc Surg (Torino) 2001;42:809-11.