ISSN : 1301-5680
e-ISSN : 2149-8156
Turkish Journal of Thoracic and Cardiovascular Surgery     
Akut tip A aort diseksiyonu için frozen elephant trunk işleminin erken ve orta dönem sonuçları
Mustafa Akbulut1, Adnan Ak1, Özgür Arslan1, Davut Çekmecelioğlu1, Serpil Taş1, Arzu Antal Dönmez1, Mesut Şişmanoğlu1, Mehmet Altuğ Tuncer1
1Department of Cardiovascular Surgery, Kartal Koşuyolu Yüksek İhtisas Training and Research Hospital, İstanbul, Turkey
DOI : 10.5606/tgkdc.dergisi.2019.16879

Abstract

Background: This study aims to investigate the early and mid-term results of total thoracic aorta repair with E-vita OPEN PLUS stent graft, which we used to remove the residual false lumen and prevent late-term complications in patients with acute type A aortic dissections.

Methods: The study included 41 patients (29 males, 12 females; mean age 51.9±10.4 years; range, 30 to 77 years) who underwent total thoracic aorta repair with frozen elephant trunk stent graft for acute type A aortic dissection between November 2013 and November 2017. The reduction in false lumen size and thrombosis were evaluated by repeated computed tomographyangiography on 10th day and third, sixth, and 12th months.

Results: Six patients (14.6%) were lost during hospital stay and one patient (2.4%) was lost during the follow-up period. Frozen elephant trunk stent graft"s distal end at descending aorta ended at T6, T7, and T8 levels in 15 (36.6%), 21 (51.2%), and five (12.2%) patients, respectively. The supra-aortic vessels were re-implanted separately in 21 (51.2%) or as island in 20 (48.8%) patients. Transient paraparesis (spinal cord ischemia) was observed in only one patient (2.4%), while permanent neurologic deficit (stroke or coma) was observed in two patients (4.9%). Mean duration of follow-up was 26.5±20.5 months. Computed tomography-angiography at first month showed that false lumen became thrombosed at rates of 93.9% and 54.5% at pulmonary trunk and diaphragmatic level, respectively.

Conclusion: We believe that total arcus repair in acute type A aortic dissection treatment with single-session frozen elephant trunk technique by ensuring early false lumen thrombosis is safe and successful.

In acute type A aortic dissections (ATAADs), the primary aim of the surgical intervention is to ensure the survival of patient by preventing aortic rupture. The principal of conventional treatment via ascending aorta replacement is to allow the distal flow by protecting the unity of aortic wall and the resection of the segment, where intimal rupture is located. Although it is a treatment protocol having successful results with acceptable mortality rates in short-term,[1-5] extension of residual false lumen towards distal in late period affects the prognosis. In patients surviving during acute period, the patent false lumen mostly leads to aneurysm in distal aorta.[4] Particularly, the development of aneurysm-caused rupture is the main reason of late-period deaths.[5] As long as false lumen stays patent, the risk of death continues in long-term, and re-operations will be inevitable.[6-8] In this study, we aimed to investigate the early and mid-term results of total thoracic aorta repair with E-vita OPEN PLUS (JOTEC GmbH, Hechingen, Germany) stent graft, which we used to remove the residual false lumen and prevent late-term complications in patients with ATAADs.

Methods

This retrospective study included 41 patients (29 males, 12 females; mean age 51.9±10.4 years; range, 30 to 77 years) who were diagnosed with ATAAD and underwent total thoracic aorta repair with frozen elephant trunk (FET) stent graft (E-vita OPEN PLUS, JOTEC GmbH, Hechingen, Germany) in Kartal Koşuyolu Yüksek İhtisas Training and Research Hospital between November 2013 and November 2017. Demographic characteristics of patients were presented in Table 1. The study protocol was approved by the Kartal Koşuyolu Yüksek İhtisas Training and Research Hospital Ethics Committee. A written informed consent was obtained from each patient. The study was conducted in accordance with the principles of the Declaration of Helsinki.

Table 1: Patients" demographic characteristics

All patients were diagnosed by computed tomography (CT) angiography and examined for cardiac function and valve pathologies with echocardiography. In all patients, the primary rupture started from ascending aorta while additional secondary rupture was observed in 13 patients (31.7%). Radiological and anatomic characteristics of the dissection were presented in Table 2.

Table 2: Radiological and anatomic features of aortic dissections

Six patients (14.6%) developed renal malperfusioncaused acute renal dysfunction. Mesenteric ischemia or visceral malperfusion was not observed in any patient. Two patients (4.9%) applied for paraplegia caused by spinal cord ischemia. One patient (2.4%) developed right hemiplegia due to occlusion of left carotid artery by dissection flap. But his neurologic deficit recovered during the transfer from neurology clinic to our hospital.

In one patient, ATAAD was detected via CT angiography performed due to the suspicion of dissection flap in echocardiography which was performed because of deterioration of medical status on second postoperative day after mitral valve replacement and tricuspid De Vega procedure. The patient underwent an urgent operation after resuscitation.

The reduction in false lumen size and thrombosis were evaluated by repeating the CT angiography on 10th day and third, sixth, and 12th months. Evaluation was performed using lumen and pseudo-lumen diameters and measurements performed at two different levels of descending aorta. Levels were determined as descending aorta at pulmonary bifurcation level[1] and the descending aorta at diaphragmatic level.[2] Thrombosis evaluation was classified in accordance with false lumen contrasting. False lumen reduction was assessed by comparison with preoperative CT angiography.

Patients underwent operation within the first 14 days from the start of back pain and other symptoms of acute dissection. Early mortality was defined as mortality within the first 30 days. Contrast thoraco-abdominal CT was utilized in diagnosis and follow-up of aortic pathologies. Acute renal dysfunction was defined as the increase in serum creatinine level higher than 1.8 mg/dL without known previous renal dysfunction. Cerebral vascular disease definition was defined as having a cerebrovascular event before 72 hours. Patients considered as suspicious by intensive care unit team for neurological deficit during physical examination were consulted by a neurologist.

In our study, the E-vita OPEN PLUS prostheses were used in all patients. Central catheter, arterial monitorization via left arm, cerebral pulse oximeter, and cerebrospinal fluid pressure catheter were used routinely in all patients. Arcus repair was performed in moderate hypothermia using unilateral selective anterograde cerebral perfusion (flow rate=10-15 mL/kg/min). However, when significant decrease in saturation was detected via cerebral pulse oximeter, bilateral anterograde selective cerebral perfusion was performed.

Median sternotomy was applied to all patients. While right subclavian artery was used for arterial cannulation, venous drainage was provided by using right atrium. Vent cannula was placed from upper-right pulmonary vein. Myocardial protection was ensured with blood cardioplegia. Proximal aorta repair was performed in cooling phase. When nasopharyngeal temperature was 26°C, aortic clamp was removed, and selective anterograde cerebral perfusion was started. E-vita OPEN PLUS prosthesis was fixed to aorta wall via single U sutures at 1 cm distal of left subclavian artery. The stent graft size was calculated by considering the real lumen diameter of aorta measured in tomography preoperatively. When the arcus elements were anastomosed with separate grafts, proximal suture line of FET graft was shifted to between left carotid artery and left subclavian artery and a fourth branch was added to provide distal perfusion. In all patients, FET prosthesis placement into the true lumen was confirmed with the guidance of trans-esophageal echocardiography. Then, the E-vita OPEN PLUS prosthesis was anastomosed to pre-implanted proximal Dacron graft. Because no dissection was detected in arcus components in isletshape arcus aorta replacement cases, arcus aorta was repaired by resecting only the small curvature of arcus aorta and protecting the unity of descending aorta and islet including the components of aortic arch as we described previously.[9]

Statistical analysis
The IBM SPSS version 22.0 (IBM Corp., Armonk, NY, USA) software was used in statistical analyses. In analyzing the study data, besides the definitive statistical methods (mean, standard deviation, and frequency), paired sample t-test was utilized in preoperative-postoperative comparison of quantitative data. A p value <0.05 was considered as statistically significant.

Results

The supra-aortic vessels were re-implanted separately in 21 (51.5%) or as island in 20 patients (48.5%). In all patients, right subclavian artery was utilized for arterial cannulation, and bilateral anterograde selective cerebral perfusion was used. Operative data and the distribution of operations by pathologies were presented in Table 3.

Table 3: Intraoperative values

Hospital mortality rate was 17.1% (n=6). The causes of death were aortic complications (n=3), multiple organ failure (n=1), stroke (n=1), and low cardiac output syndrome (n=1). One patient had Marfan syndrome and died on second postoperative day due to bleeding diathesis.

Second patient who had Marfan syndrome applied to our clinic with complaint of difficulty in breathing one month postoperatively. No aortic pathology could be detected in the patient, but he was intubated due to pulmonary regurgitation, and died in 66th postoperative day due to multiple organ failure. Third patient was 76 years old and applied to another center with complaint of dyspnea. No aortic complication was detected in controls and he was diagnosed with pneumonia, but died due to pulmonary failure.

Frozen elephant trunk stent graft"s distal end at descending aorta ended at T6, T7, and T8 levels in 15 (36.6%), 21 (51.2%), and five (12.2%) patients, respectively. While paraparesis (spinal cord ischemia) was observed in only one patient (2.4%), permanent neurologic deficit (stroke or coma) was observed in two patients (4.9%). The patient having paraparesis had no neurologic deficit when discharged. Other postoperative complications were presented in Table 4.

Table 4: Postoperative values

Data of 24 patients were compiled for followup until January 2018 and only one patient died during follow-up. Mean duration of follow-up was 26.5±20.5 months. Besides the decrease in aorta diameters, false lumen was thrombosed in short-term. Postoperative CT findings were presented in Table 5.

Table 5: Computed tomography-angiography findings at follow-up (n=33)

Pre- and postoperative aortic diameters were compared with t-test in dependent groups. There was a statistically significant difference between pre- (37.4±8.9) and postoperative (31.8±4.9, p<0.001) aortic diameters. The mean difference between the two groups was 5.60 mm (95% confidence interval [8.10-3.09]) (Figure 1).

Figure 1: Comparison of pre- and postoperative aortic diameters.

Discussion

In ATAAD, which has high mortality and morbidity rates and courses noisily, the main aim is to save the life of patient.[10-12] Immediate, simple, and effective repair of proximal aorta or hemi arcus aorta has successful results in short-term.[13-15] However, the development of late complications in long-term and the remarkably high reoperation rates have effects on mortality and the quality of life of patient.[1,16]

The first 30-day mortality rate of conventional type A aortic dissection surgery has been reported to be between 9% and 21%.[13,14] In a systematic examination and meta-analysis of Tian et al.[17] on FET-implemented patients, the first 30-day mortality in ATAAD has been reported to be 7.7% (0-18.2%). The mortality rates represented in our study are compatible with the literature.

While Uchida et al.[18] reported 2.5% for stroke, 3.8% for transient renal failure, 7.5% for lung failure, and 5% for bleeding revision in postoperative follow-up, Roselli et al.[19] reported the stroke rate as 12%, lung failure as 12%, and renal failure as 19%. Both teams have reported the percentage of paraplegia as 0%. In our study, the percentage of stroke was observed to be 6.9%, pulmonary complications 7%, and newly developed renal failure 14.6%, while no paraplegia was observed.

The most feared complication that can develop even though measures are taken for FET is the newly developed neurologic deficit.[20] In a multi-center study of Tsakagis et al.,[21] the percentage of stroke development has been reported to be 10%, while the percentage of paraparesis has been observed to be 1%. Moreover, in a meta-analysis of their study of FET implementation in ATAAD, Tian et al.[17] have reported stroke between 0% and 11.8% and spinal cord damage between 0% and 8.3%. Even if advanced age is considered to be a risk factor for stroke,[22] aortic dissection involving acute pathology forms an operation-independent risk factor. However, the stent graft ends below T8 and the occlusion of the intercostal arteries due to the closure of the left subclavian artery by the graft are accepted to be particular predisposing risk factors for spinal cord damage. Our study produced similar results with the literature.

Supra-coronary graft replacement is a simple and classical treatment method of ATAAD. Residual dissection due to patent false lumen may develop complications that consequently necessitate reoperation in long-term and increase mortality. The reoperation risk of aorta in distal residual dissection segment after conventional dissection surgery is at a remarkable level of 30%.[6-8] There are three important factors here: segmented diameters of aorta, non-thrombosed false lumen, and uncontrollable hypertension.[23] With FET technique, false lumen decreases and becomes totally thrombosed at the level of graft even in shortterm. In segment at distal of the graft, false lumen has been determined to be highly thrombosed.[24-25] In our study, C T angiography performed in the follow-up showed that false lumen became fully thrombosed at rates of 93.9% and 54.5% at pulmonary trunk and diaphragmatic level, respectively.

The limited number of retrospective data and cases limits our study; however, the study could represent the advantages and success of single-phase distal aorta treatment of ATAAD in mid-term. Longterm follow-up is required to compare the results of FET technique with residual-dissection-caused complications observed in long-term.

In conclusion, to prevent complications such as rupture and malperfusion that can develop due to false lumen gap, we believe that performing total arcus repair in acute type A aortic dissection treatment with single-session frozen elephant trunk technique by ensuring early false lumen thrombosis is safe and successful.

Declaration of conflicting interests
The authors declared no conflicts of interest with respect to the authorship and/or publication of this article.

Funding
The authors received no financial support for the research and/or authorship of this article.

EDITORIAL COMMENT
Anıl Z. Apaydın
Type A acute aortic dissection (TAAAD) is the most c atastrophic d isease o f t he a orta. P atients with TAAAD may present with a wide variety of symptoms and the clinical picture may vary from a very stable one to a state of shock due to tamponade or severe malperfusion. The primary goal of the operation for this lethal disease is the survival of the patient. There are number of surgical alternatives ranging from a simple ascending aortic replacement to valve preserving root replacement and total arch replacement. The secondary goal is to provide the surviving patient with a life eliminating future risks of possible distal aortic rupture or intervention/ operation.

According to the authors of this article, total arch replacement with frozen elephant trunk (FET) is a procedure which can achieve the aforementioned goals.[1] However, I have concerns about the efficacy and the safety of this operation.

The idea of elephant trunk operation emerged as a two-stage solution in patients with mega-aortic pathologies to facilitate the second stage. It received criticism due to high combined mortality of the two stages and the interval between them. With the introduction of endovascular techniques, the second stage could have been completed by a thoracic endovascular aortic repair (TEVAR) procedure. The technique of FET with the use of hybrid grafts facilitated the second stage even further by providing a convenient landing zone. The FET has been used in TAAAD to obliterate the false lumen in the descending aorta with the expectation that it would prevent the dilatation of the distal aorta in long-term and it would relieve the malperfusion in short-term.

In their retrospective analysis of 41 patients with TAAAD who underwent total arch replacement with FET, the authors reported that the false lumen of the descending aorta became thrombosed, particularly at the proximal part.[1] The authors a lso r eported t hat this technique decreased the size of the descending aortic diameter, compared to the preoperative values. The overall mortality and morbidity rates in this series compare favorably with those in previous similar reports. However, the rate of malperfusion (particularly the visceral malperfusion which was not seen in the series) is less than the usual reports regarding acute dissection. It is well-known that malperfusion syndrome which is seen in about 30% of the TAAAD significantly increases the operative mortality.[2] The difference between the pre- and postoperative diameters of the descending aorta could be explained by the pressure drop in the false channel by the closure/ exclusion of the intimal tear during the proximal repair, not because of the implementation of FET. The rate of temporary neurological dysfunction (i.e., lethargy and agitation) and left diaphragm paralysis due to a trauma to the recurrent laryngeal nerve should have been also mentioned, since they are common complications of prolonged brain protection and total arch replacement, respectively.

The FET is a technically difficult operation, particularly in patients with TAAAD considering the inherited risks of this disease such as friable aorta, coagulation problems, and metabolic changes due to malperfusion. The reported bleeding and tamponade rate in this series seems to be slightly high. It may not be easy to place a stented graft into a dissected descending aorta in every patient and stent-induced new entry is another potential problem.

This technique can not overcome the impact of distal reentries below the bottom of the FET which can cause the dilatation of those segments. The rate of distal reinterventions was significant in a report of 94 TAAAD patients who underwent FET.[3] In a report by Zierer,[4] i n which t he follow-up was 100% c omplete, only 15 distal aortic reoperations were required in 168 operative survivors of TAAAD within a mean period of 60±50 months postoperatively. Therefore, every patient does not need a prophylaxis. The factors which influence the natural history of the residual aorta still remain incompletely understood and the effect of the patent false lumen on the prognosis is debatable.

To expose an acutely ill patient to a longer period of brain and lower body ischemia for a prophylactic application of FET should be only justified by a very solid evidence. To the best of my knowledge, it is not available yet. Currently, this approach should be used in clinically stable patients with a tear or rentry tear in the distal aortic arch or proximal descending aorta.

Despite all the criticism I have made for this technique, I do appreciate the current work and also, the ongoing efforts of this group for pioneering FET technique in Turkey in an attempt to provide dissection patients with an improved quality of life without secondary interventions.

REFERENCES
1. Akbulut M, Ak A, Arslan Ö, Çekmecelioğlu D, Taş S, Antal Dönmez A, et al. Early and mid-term results of frozen elephant trunk procedure for acute type A aortic dissection. Turk Gogus Kalp Dama 2019;27:135-42.

2. Apaydın AZ, Büket S, Posacıoğlu H, İslamoğlu F, Çalkavur T, Yağdı T, et al. Perioperative risk factors for mortality in patients with acute type A aortic dissection. Annals of Thoracic Surgery 2002;74:2034-39.

3. Shrestha M, Haverich A, Martens A. Total aortic arch replacement with the frozen elephant trunk procedure in acute DeBakey type I aortic dissections. Eur J Cardiothorac Surg 2017;51:i29-i34.

4. Zierer A, Voeller RK, Hill KE, Kouchoukos NT, Damiano Jr RJ, Moon MR, et al. Aortic Enlargement and Late Reoperation After Repair of Acute Type A Aortic Dissection. Ann Thorac Surg 2007;84:479-86.

Correspondence: Anıl Z. Apaydın, MD. Ege Üniversitesi Tıp Fakültesi
Kalp ve Damar Cerrahisi Anabilim Dalı, 35100 Bornova, İzmir, Turkey. Tel: +90 232 - 388 10 23 e-mail: anil.apaydin@ege.edu.tr

References

1) Geirsson A, Bavaria JE, Swarr D, Keane MG, Woo YJ, Szeto WY, et al. Fate of the residual distal and proximal aorta after acute type a dissection repair using a contemporary surgical reconstruction algorithm. Ann Thorac Surg 2007;84:1955-64.

2) Tan ME, Morshuis WJ, Dossche KM, Kelder JC, Waanders FG, Schepens MA. Long-term results after 27 years of surgical treatment of acute type a aortic dissection. Ann Thorac Surg 2005;80:523-9.

3) Danner BC, Natour E, Horst M, Dikov V, Ghosh PK, Dapunt OE. Comparison of operative techniques in acute type A aortic dissection performing the distal anastomosis. J Card Surg 2007;22:105-10.

4) Özçınar E, Çakıcı M, Baran Ç, Gümüş F, Özgür A, Yazıcıoğlu L, et al. Results of late-onset type A aortic dissection after previous cardiac surgery: Does prior coronary artery bypass grafting affect survival? Turk Gogus Kalp Dama 2018;26:1-7.

5) DeBakey ME, McCollum CH, Crawford ES, Morris GC Jr, Howell J, Noon GP, et al. Dissection and dissecting aneurysms of the aorta: twenty-year follow-up of five hundred twenty-seven patients treated surgically. Surgery 1982;92:1118-34.

6) Tsagakis K, Tossios P, Kamler M, Benedik J, Natour D, Eggebrecht H, et al. The DeBakey classification exactly reflects late outcome and re-intervention probability in acute aortic dissection with a slightly modified type II definition. Eur J Cardiothorac Surg 2011;40:1078-84.

7) Malvindi PG, van Putte BP, Sonker U, Heijmen RH, Schepens MA, Morshuis WJ. Reoperation after acute type a aortic dissection repair: a series of 104 patients. Ann Thorac Surg 2013;95:922-7.

8) Gariboldi V, Grisoli D, Kerbaul F, Giorgi R, Riberi A, Metras D, et al. Long-term outcomes after repaired acute type A aortic dissections. Interact Cardiovasc Thorac Surg 2007;6:47-51.

9) Akbulut M, Arslan O, Ak A, Tas S, Cekmecelioglu D, Donmez AA, et al. Early period results for repair of complex thoracic aortic diseases with E-vita open stent graft. EJCM 2017;5:1-6

10) Trimarchi S, Nienaber CA, Rampoldi V, Myrmel T, Suzuki T, Mehta RH, et al. Contemporary results of surgery in acute type A aortic dissection: The International Registry of Acute Aortic Dissection experience. J Thorac Cardiovasc Surg 2005;129:112-22.

11) Hiratzka LF, Bakris GL, Beckman JA, Bersin RM, Carr VF, Casey DE Jr, et al. 2010 ACCF/AHA/AATS/ACR/ASA/ SCA/SCAI/SIR/STS/SVM guidelines for the diagnosis and management of patients with thoracic aortic disease: executive summary. A report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines, American Association for Thoracic Surgery, American College of Radiology, American Stroke Association, Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, Society of Interventional Radiology, Society of Thoracic Surgeons, and Society for Vascular Medicine. Catheter Cardiovasc Interv 2010;76:E43-86.

12) Westaby S, Saito S, Katsumata T. Acute type A dissection: conservative methods provide consistently low mortality. Ann Thorac Surg 2002;73:707-13.

13) Crawford ES, Kirklin JW, Naftel DC, Svensson LG, Coselli JS, Safi HJ. Surgery for acute dissection of ascending aorta. Should the arch be included? J Thorac Cardiovasc Surg 1992;104:46-59.

14) Crawford ES, Svensson LG, Coselli JS, Safi HJ, Hess KR. Aortic dissection and dissecting aortic aneurysms. Ann Surg 1988;208:254-73.

15) David TE, Armstrong S, Ivanov J, Barnard S. Surgery for acute type A aortic dissection. Ann Thorac Surg 1999;67:1999-2001.

16) Kirsch M, Soustelle C, Houël R, Hillion ML, Loisance D. Risk factor analysis for proximal and distal reoperations after surgery for acute type A aortic dissection. J Thorac Cardiovasc Surg 2002;123:318-25.

17) Tian DH, Wan B, Di Eusanio M, Black D, Yan TD. A systematic review and meta-analysis on the safety and efficacy of the frozen elephant trunk technique in aortic arch surgery. Ann Cardiothorac Surg 2013;2:581-91.

18) Uchida N, Katayama A, Tamura K, Sutoh M, Kuraoka M, Ishihara H. Frozen elephant trunk technique and partial remodeling for acute type A aortic dissection. Eur J Cardiothorac Surg 2011;40:1066-71.

19) Roselli EE, Rafael A, Soltesz EG, Canale L, Lytle BW. Simplified frozen elephant trunk repair for acute DeBakey type I dissection. J Thorac Cardiovasc Surg 2013;145:197-201.

20) Bavaria JE, Brinster DR, Gorman RC, Woo YJ, Gleason T, Pochettino A. Advances in the treatment of acute type A dissection: an integrated approach. Ann Thorac Surg 2002;74:1848-52.

21) Tsagakis K, Pacini D, Di Bartolomeo R, Gorlitzer M, Weiss G, Grabenwoger M, et al. Multicenter early experience with extended aortic repair in acute aortic dissection: is simultaneous descending stent grafting justified? J Thorac Cardiovasc Surg 2010;140:116-20.

22) Rylski B, Suedkamp M, Beyersdorf F, Nitsch B, Hoffmann I, Blettner M, et al. Outcome after surgery for acute aortic dissection type A in patients over 70 years: data analysis from the German Registry for Acute Aortic Dissection Type A (GERAADA). Eur J Cardiothorac Surg 2011;40:435-40.

23) Zierer A, Voeller RK, Hill KE, Kouchoukos NT, Damiano RJ Jr, Moon MR. Aortic enlargement and late reoperation after repair of acute type A aortic dissection. Ann Thorac Surg 2007;84:479-86.

24) Gorlitzer M, Weiss G, Meinhart J, Waldenberger F, Thalmann M, Folkmann S, et al. Fate of the false lumen after combined surgical and endovascular repair treating Stanford type A aortic dissections. Ann Thorac Surg 2010;89:794-9.

25) Uchida N, Shibamura H, Katayama A, Shimada N, Sutoh M. Total arch replacement with an open stent graft for acute type A aortic dissection: fate of the false lumen. Eur J Cardiothorac Surg 2009;35:83-8.

Keywords : Aort bölgeleri, sahte lümen, frozen elephant trunk, tip A aort diseksiyonu
Viewed : 6593