ISSN : 1301-5680
e-ISSN : 2149-8156
Turkish Journal of Thoracic and Cardiovascular Surgery     
Treatment of dialysis access-associated steal syndrome with pressure monitorization-assisted PTFE banding
İsmail Cihan Özbek, Ali Kocailik, Kenan Sever, Denyan Mansuroğlu
Özel Gaziosmanpaşa Hastanesi Kalp ve Damar Cerrahisi Bölümü, İstanbul
DOI : 10.5606/tgkdc.dergisi.2011.009
Background: We evaluated the mid-term effects on the fistula patency and clinical results of our technique of banding combined with pressure measurement from the distal bed.

Methods: The mid-term results of 20 patients who were diagnosed with symptomatic steal syndrome by clinical and Doppler USG evaluation and treated with arterially pressure monitorized polytetrafluoroethylene (PTFE) banding method between January 2002 - December 2009 were studied. All the patients had aneurysmatic brachiocephalic arteriovenous fistula (AVF). Peroperatively, blood pressure was monitorized from the proximal of the fistula, brachial artery and radial artery and the radial/ brachial index values were recorded. Fistulas were constricted until the lower treshold of the radial-brachial index became 0.6. For the banding procedure PTFE grafts long enough to completely cover the aneurysmatic segment were used. Postoperatively, patients were asked to return for follow-ups within the 1st month and at three-month intervals thereafter. The fistula patency and the symptoms were evaluated and recorded in the follow-ups.

Results: Symptoms were not alleviated in three patients at the 1st month follow-up. These patients underwent rebanding. In the remaining patients no early or late complications developed. All patients could receive hemodialysis in the early period and the symptoms were resolved. Other than the two patients who underwent rebanding, no cases of thrombosis were detected at the end of the first year.

Conclusion: The main surgical procedures for surgical treatment of post-AVF steal syndrome are distal revascularization-interval ligation, banding, T-banding, graft interpositioning and AVF ligation. There are no large surgery studies involving patients treated with these methods. While banding procedure is technically easy, insufficient banding causes perpetuation of steal syndrome and more than necessary constriction causes thrombosis. In this study one year patency and thrombosis rates were 90% and 10%, respectively and the rate of relief of symptoms was 95%. We think that controlled banding with brachial and radial artery pressure monitoring reduces risk of fistula thrombosis and repeat procedures for insufficient constructions.

Keywords : Arteriovenous fistula; polytetrafluoroethylene banding; steal syndrome
Viewed : 12831
Downloaded : 3497