Combined use of barrier methods to prevent pericardial adhesions: is it always better?
Oktay Korun1, Şafak Alpat1, Sevgen Önder2, Rıza Doğan1, İlhan Paşaoğlu1, Metin Demircin1, Mustafa Yılmaz1
1Departments of Cardiovascular Surgery, Hacettepe University Faculty of Medicine, Ankara, Turkey
2Departments of Pathology, Hacettepe University Faculty of Medicine, Ankara, Turkey
DOI : 10.5606/tgkdc.dergisi.2017.13955
Background: This study aims to investigate the effects of combined and individual use of pericardial closure, expanded polytetrafluoroethylene membrane and resorbable adhesion barrier (REPEL-CV®) on pericardial adhesions on a rabbit model.

Methods: Thirty rabbits were randomly assigned to six groups: control, pericardium, expanded polytetrafluoroethylene, resorbable membrane, expanded polytetrafluoroethylene + resorbable membrane, and pericardium + resorbable membrane. At the postoperative five weeks, the tenacity of the adhesions was evaluated using a qualitative grading system, and histological specimens were examined.

Results: Resorbable membrane group had significantly lower tenacity scores, compared to the control, pericardium, and expanded polytetrafluoroethylene groups (p<0.01). The scores of the expanded polytetrafluoroethylene + resorbable membrane and pericardium + resorbable membrane groups were lower than the control group (p<0.05 and p<0.01 respectively). Combined use of resorbable membrane, compared to the solitary use, did not produce significantly different tenacity scores. Macroscopically, in the resorbable membrane group after sternotomy, there were filmy adhesions over the epicardium which could be easily dissected digitally. In the expanded polytetrafluoroethylene + resorbable membrane and pericardium + resorbable membrane groups, there were also adhesions beneath the sternum.

Conclusion: Resorbable membrane was effective in reducing postoperative pericardial adhesions when used alone or in combination with expanded polytetrafluoroethylene membrane or pericardial closure. Solitary use of resorbable membrane, compared to combined use, can be preferable, since the addition of expanded polytetrafluoroethylene membrane and pericardial closure increase substernal fibrosis.

Keywords : Biocompatible materials; reoperation; surgical adhesions