ISSN : 1301-5680
e-ISSN : 2149-8156
Turkish Journal of Thoracic and Cardiovascular Surgery     
Kasık bölgesinde tam damar korumasında sarmal rektus abdominis flebi
Eyüphan Gencel1, Cengiz Eser1, Erol Kesiktaş1, Uğur Göçen2, Atakan Atalay2
1Departments of Plastic, Reconstructive and Aesthetic Surgery, Medical Faculty of Çukurova University, Adana, Turkey
2Departments of Cardiovascular Surgery, Medical Faculty of Çukurova University, Adana, Turkey
DOI : 10.5606/tgkdc.dergisi.2015.11769

Özet

In this article, we present a novel method utilizing a wraparound muscle flap for the treatment of groin wounds with infected vascular grafts or femoral vessels. Five patients underwent operations involving the wrap-around vertical rectus abdominis muscle flap due to peripheral arterial disease (n=3) or high-energy gunshot trauma (n=2). Hemorrhagic complications were not encountered in patients with gunshot wounds. No portion of the vascular system became exposed during the two year follow-up period. Among those with peripheral vascular disease, one patient died and one patient underwent a late amputation. We suggest that the wrapping technique can decrease the early postoperative complications in patients with highenergy gunshot wounds.

The management of complex groin wounds, which also involves the vascular system, is of utmost importance for limb salvage. The use of muscle flaps is well known in such cases. However, the complete wrapping of the muscle around the vascular system (wrap-around technique) has not been documented in the groin region. Herein, we present the results of wrapping the femoral artery with the vertical rectus abdominis muscle (VRAM) to manage five complex groin defects.

In this retrospective case series, the records of five patients who underwent a wrap-around VRAM flap operation between January 2012 and May 2014 were analyzed. An informed consent was obtained from each patient. All patients had large groin defects with exposed vascular systems. The patient characteristics are shown in Table 1. Hemorrhage, infection, flap loss and amputation were considered to be possible complications. Magnetic resonance imaging (MRI) was used to evaluate the muscle viability during the third month.

Table 1: Demographic and clinical variables

Surgical technique
Under general anesthesia, the cardiovascular team performed vascular interventions with debridement around the femoral vessels. Vascular graft infections were confirmed based on excised alloplast cultures from specimens obtained during the operations. An “ipsilateral” (cases 2, 3, and 5) or “contralateral” (cases 1 and 4) VRAM flap was performed depending on the choice of a suitable flap pedicle. The flap was created through a longitudinal, mid-abdominal incision, preserving the umbilicus. The fascia closure (without mesh) was performed with a 2-4 cm opening which allowed the muscle cuff to pass through. Care was taken to protect the small muscle cuff at the pubic bone to prevent the pedicle from stretching. The VRAM flap was wrapped and sutured circularly only around the superficial femoral artery or vascular graft (Figure 1a, b). All anastomosis sites were completely covered by muscle. A split thickness skin graft was applied to the muscle surface (Case 1: Figure 1d, e; Case 2: Figure 1f, g; Case 3: Figure 1h, ı; Case 5: Figure 1j, k).

All vascular grafts were replaced during surgery. Tissue and excised graft cultures indicated the presence of Acinetobacter baumannii and Pseudomonas and the patients were treated accordingly. No hemorrhage was noted at the surgical wrapped site. All muscle flaps survived completely. No vessels or prosthetic grafts were exposed as documented with MRI imaging (Figure 1c). The postoperative graft (3/5 cases) patency was 66.6% by MRI (Case 5 - died). The follow-up period ranged from 1 to 36 months (mean: 14.4 months). The patients with peripheral artery disease (PAD) suffered from two major complications. One patient (Case 5) died (postoperative day 30) from diabetic complications-related sepsis. The other patient (Case 4) experienced hip disarticulation after four months of follow-up.

Figure 1: (a, b) Preoperative view of the VRAM-wrapped isolated femoral artery. (c) Magnetic resonance imaging of the completely wrapped superficial femoral artery with VRAM (Arrow). High-energy gunshot wound cases: (d) Case 1: Postoperative week two. (e) Postoperative week four. (f) Case 2: VRAM-wrapped superficial femoral artery. (g) Postoperative month six. Peripheral vascular disease cases: (h) Case 3: After VRAM was harvested. (i) Postoperative month 24. (j) Case 5: Wrapped vascular graft, (k) Postoperative view. VRAM: Vertical rectus abdominis muscle.

Tartışma

To date, a muscle wrapping technique for vascular system protection in the groin has not been reported. Surgeons routinely wrap a portion of a muscle over the exposed graft; however, they do not completely wrap the graft. The first case report involving the salvage of an infected axillofemoral prosthetic vascular graft was performed via a superiorly based rectus abdominis wrap-around muscle flap.[1] The salvage of infected grafts by wrapping a saphenous patch was reported by De Santis.[2] In our patients, we wrapped the VRAM to isolate the vascular system. On the other hand, the VRAM technique has several disadvantages including donor area scars, infection spreading to the abdomen or other late morbidities, such as incisional hernias.[3] Anterolateral thigh flap (ALT) was compared to VRAM for groin reconstruction.[3] The primary disadvantages of the ALT flap in our cases were as follows: large skin defects on the thigh region, and obliterated or disrupted continuity of the profunda femoris artery (PFA).

Furthermore, the mortality rates are high in patients with prosthetic graft infections in the groin region which are related to PAD.[4] In PAD group, one patient died due to sepsis. Profunda femoris artery revascularization is a critical aspect of controlling thigh infections to prevent hip disarticulation, as described by Poi.[5] The long-term limb amputation and mortality rates in patients with PAD are still high (40%) and these rates are closely related to comorbidities. In our study, we observed no graft complications with normal PFAs in the patients with gunshot wounds.

However, this study has some limitations. Firstly, the sample size was small. Secondly, the follow-up period was less than five years. Further large-scale studies with long-term follow-up are required to confirm these results.

In conclusion, our study results suggest that the wrap-around technique can decrease the risk of complications during the reconstruction of complex groin defects in patients with high-energy gunshot wounds. For patients with PAD, this technique should be applied more cautiously.

Declaration of conflicting interests
The authors declared no conflicts of interest with respect to the authorship and/or publication of this article.

Funding
The authors received no financial support for the research and/or authorship of this article.

Anahtar Kelimeler : Kasık; periferik arter hastalığı; ameliyat sonrası komplikasyon; rektus abdominis; yumuşak doku enfeksiyonu
Viewed : 8675
Downloaded : 1574