Negative pressure wound closure system is useful for managing large, problematic wounds that are almost totally open, filling tissue defects in patients with Fournier"s gangrene, managing open abdomen after gunshot injury, allowing transient closure of the abdomen during care of abdominal compartment syndrome, and facilitating the management of diabetic foot complications.[3-6] In this article, we report a successful application of thoracic NPWCS to fill a thoracic defect, control infection, and expand the lung in a patient with three-rib defect, lung parenchyma injury, empyema, left complete pneumothorax, and visible pericardium after a gunshot injury.
Initially, we applied NPWCS every other day and then once every four days according to the condition of his wound: a total of 23 times (Figure 2). We achieved control of the infection, expansion of the lung, and diminishment of the wound via improved granulation tissue on the thoracic wall by reduced number of sponges with every other dressing change.
Figure 2: Application of negative pressure wound closure system.
We used the abdominal type of NPWCS, which has a tissue protective layer, because of the patient"s visible subclavian artery and vein around the adjacent pericardium and the lung apex at the time of initial NPWCS application. In addition, we wanted to avoid contact of the sponges with the pericardium. The pericardium, artery and vein were protected from contact with the sponges via the tissue protective layer of the abdominal type of NPWCS. Downsizing of the wound was achieved in three months (Figure 3).
Figure 3: Diminished thoracic defect.
No enlargement occurred in the air leakage areas of the lung parenchyma. Air leakage was precluded by Vicryl sutures with pledgets at the beginning of the patient"s hospitalization. We applied a small dressing with antibiotic pomades to preclude the loss of negative pressure over two reactivated air leakage areas. After the 10th application of NPWCS, we discontinued use of the abdominal type of NPWCS; we changed to the standard NPWCS because the lung expanded, the artery and vein became invisible, and granulation tissue on the lung improved. The sepsis totally resolved after the 12th dressing change. The patient was removed from ventilation and had spontaneous respiration. After the 19th dressing change, the lung was totally expanded and filled the thoracic cavity. Dressing changes thereafter were applied for the purpose of reducing the thoracic defect. Air leakage from the lung stopped when the thoracic defect decreased to 4¥4 cm. After that, the skin underwent primary suturing after release from the two sides of the wound lips (Figure 4a, b). The silicon drain under the skin closure was removed on the fifth day after suturation. The patient was discharged after suture removal. The difference could be seen comparing the lung X-ray at the time of first admission and the lung X-ray at discharge (Figure 5a, b). The first X-ray revealed that the lung was totally collapsed, and the last X-ray demonstrated that the lung had expanded and totally filled the thoracic space.
Figure 4: (a) Before and (b) after closure of thoracic wound.
Figure 5: Lung X-rays of the patient (a) at first admission and (b) at discharge.
Upon admission, the patient"s left lung was totally collapsed and it had thick fibrotic pleura such that expansion of the lung was not possible. In order to expand the lung at that time, it needed decortication, but the patient was suffering from SIRS and septic shock. We predicted that the lung could be expanded slowly by application of NPWCS to the thoracic space. The accuracy of our prediction may be seen by comparing the lung X-ray at the time of first admission and the lung X-ray at discharge. The first X-ray revealed that the lung was totally collapsed, and the last X-ray demonstrated that the lung had expanded and totally filled the thoracic space. Because of these features, we decided to use the NPWCS for our patient.
We focused on resolving regional edema, reducing bacterial colonization, and re-expanding the lung. Initially, we used the abdominal type of NPWCS because this type has an organ-preserving layer. We covered the sponge with organ preserving film-layer to avoid organ or vascular damage. This placement of the sponges prevents fistulization and major bleeding. We started with a -75 mmHg negative pressure level. When we observed sufficient granulation tissue on the lung after the fourth dressing change, we increased the pressure to 125 mmHg. After the 10th dressing change, we observed that there was sufficient granulation tissue, and we discontinued using the organ-preserving layer and started using the standard dressing style. We reduced the size of the sponge when we saw lung expansion. We believe that the NPWCS played a prominent role in the rapid successful healing of the large wound of our patient.
In conclusion, negative pressure wound closure system may be used to prevent high mortality and morbidity from a high-energy gunshot injury that produces a huge thoracic defect and open thorax with empyema, particularly if the patient has total lung collapse, fibrotic and thickened pleura and impossible decortication. However, caution is needed during the procedure; the pericardium and major vascular structures must be well-protected, and care must be taken to avoid possible complications. Multiple sessions of debridement and surgery are required, and the injury site(s) must be protected with appropriate and frequent dressing changes. The use of negative pressure wound closure system therapy to treat such patients facilitates recovery, and offers a "civilized," cost-effective treatment.[16] The excellent result obtained in our patient demonstrates that the negative pressure wound closure system is a good choice for treating high-energy thoracic injuries by reducing wound infection, increasing wound neovascularization and oxygenation, enhancing wound healing, and enabling early wound closure.
Acknowledgement
The authors thank Marilyn Carlson for her editorial
assistance.
Declaration of conflicting interests
The authors declared no conflicts of interest with respect to
the authorship and/or publication of this article.
Funding
The authors received no financial support for the research
and/or authorship of this article.
1) Argenta LC, Morykwas MJ. Vacuum-assisted closure: a new
method for wound control and treatment: clinical experience.
Ann Plast Surg 1997;38:563-76.
2) Demir A, Demirtaş Y, Ciftci M, Öztürk N, Karacalar A.
Topical negative pressure vacuum assisted closure (VAC)
applications. Türk Plast Rekonstr Est Cer Derg 2006;14:171-7.
3) Ozer MT, Coskun AK, Ozerhan IH, Ersoz N, Yildiz R, Sinan
H, et al. Use of vacuum-assisted closure (VAC?) in highenergy
complicated perineal injuries: analysis of nine cases.
Int Wound J 2011;8:599-607.
4) Ozturk E, Ozguc H, Yilmazlar T. The use of vacuum assisted
closure therapy in the management of Fournier's gangrene.
Am J Surg 2009;197:660-5.
5) Simsek A, Ozer MT, Eryilmaz M, Ozturk E, Ozerhan IH,
Gorgulu S, et al. The results of damage control surgery in abdominal trauma. Balkan Military Medical Review
2007;10:136-40.
6) Stuhmiller J, Phillips, YY, Richmond DR. The physics and
mechanisms of primary blast injury. Washington DC: Office
of the Surgeon General of the US Army; 1991.
7) Fleischmann W, Strecker W, Bombelli M, Kinzl L. Vacuum
sealing as treatment of soft tissue damage in open fractures.
Unfallchirurg 1993;96:488-92. [Abstract]
8) Herscovici D Jr, Sanders RW, Scaduto JM, Infante A,
DiPasquale T. Vacuum-assisted wound closure (VAC therapy)
for the management of patients with high-energy soft tissue
injuries. J Orthop Trauma 2003;17:683-8.
9) Labler L, Keel M, Trentz O (2004) Vacuum assisted closure
(V.A.C.) for temporary coverage of soft tissue injury in type III
open fracture of lower extremities. Eur J Trauma 2004;30:305-12.
10) Labler L, Oehy K. Vacuum sealing of problem wounds.
Swiss Surg 2002;8:266-72. [Abstract]
11) Morykwas MJ, Argenta LC, Shelton-Brown EI, McGuirt W.
Vacuum-assisted closure: a new method for wound control
and treatment: animal studies and basic foundation. Ann
Plast Surg 1997;38:553-62.
12) Müllner T, Mrkonjic L, Kwasny O, Vécsei V. The use of
negative pressure to promote the healing of tissue defects: a
clinical trial using the vacuum sealing technique. Br J Plast
Surg 1997;50:194-9.
13) Hak DJ, Olson SA, Matta JM. Diagnosis and management of
closed internal degloving injuries associated with pelvic and
acetabular fractures: the Morel-Lavallée lesion. J Trauma
1997;42:1046-51.
14) Rocco G, Cecere C, La Rocca A, Martucci N, Salvi R,
Passera E, et al. Caveats in using vacuum-assisted closure
for post-pneumonectomy empyema. Eur J Cardiothorac Surg
2012;41:1069-71.