Methods: Anticoagulant therapy regimens for pregnant women who underwent mechanical heart valve replacement between January 1990 and December 2015 was analyzed retrospectively. Seventy-two pregnancies among 57 patients after mechanical heart valve replacement were reviewed, and four different regimens were identified and evaluated during different trimesters of pregnancy.
Results: Forty of 72 pregnancies resulted in healthy newborns; 35 (48.6%) healthy neonates, four (5.6%) premature births, and one (1.4%) low birth weight. Eighteen (25%) therapeutic and 12 (16.7%) spontaneous abortions, as well as two (2.8%) stillbirths occurred. Seven valve thromboses developed during pregnancy or the postpartum period. Bleeding occurred in six patients (10.5%) and peripheral embolism also occurred in six patients (10.5%). No maternal mortalities were recorded.
Conclusion: Although there is no consensus on the most optimal anticoagulant regimen during pregnancy, substituting warfarin with dose-adjusted unfractionated heparin or low-molecularweight heparin seems suitable to prevent teratogenicity and a high abortion rate in the first trimester. Low-molecular-weight heparin is practical to use and can be monitored reliably, resulting in successful pregnancy outcomes. However, warfarin throughout pregnancy ≤5 mg per day may be an alternative choice, if the risk of embryopathy is accepted by the pregnant woman.