ISSN : 1301-5680
e-ISSN : 2149-8156
Turkish Journal of Thoracic and Cardiovascular Surgery     
The intracranial effects of flow reversal during transcarotid artery revascularization
Busra Tok Cekmecelioglu1,2,3, Peter Legeza1,4, Pooja Tekula1, Martin Giesecke5, Charudatta S. Bavare1, Zsolt Garami1, Alan Lumsden1
1Department of Cardiovascular Surgery, Houston Methodist Hospital, Houston, Texas, USA
2Department of Outcomes Research, Cleveland Clinic, Cleveland, Ohio, USA
3Department of Anesthesiology, Cleveland Clinic, Cleveland, Ohio, USA
4Department of Vascular and Endovascular Surgery, Semmelweis University, Budapest, Hungary
5Department of Anesthesiology, Houston Methodist Hospital, Houston, Texas, USA
DOI : 10.5606/tgkdc.dergisi.2024.25700
Background: This study aimed to assess intraoperative cerebral hemodynamic responses and embolic events during transcarotid artery revascularization via transcranial Doppler, near-infrared spectroscopy, and bispectral index monitoring.

Methods: Twelve patients (7 males, 5 females; mean age: 72.8±9.0 years; range, 63 to 91 years) undergoing transcarotid artery revascularization with simultaneous transcranial Doppler, near-infrared spectroscopy, and bispectral index monitoring were analyzed in this retrospective study between September 2017 and December 2019. The mean flow velocity and pulsatility index of the middle cerebral artery, alongside near-infrared spectroscopy and bispectral index values, before flow reversal, during flow reversal, and after flow reversal phases were investigated. The presence and frequency of high-intensity transient signals were recorded to evaluate embolic incidents.

Results: Significant reductions in middle cerebral artery mean flow velocity were noted during flow reversal (40.58±10.57 cm/sec to 20.58±14.34 cm/sec, p=0.0004), which subsequently returned to and exceeded baseline values after flow reversal cessation (53.33±17.69 cm/sec, p=0.0005). Near-infrared spectroscopy (71±4.4% to 66±6.2%) and bispectral index (45.71±8.5 to 40.14±8.1) values mirrored these hemodynamic changes, with notable decreases during flow reversal, and recoveries after flow reversal. The highest concentration of high-intensity transient signals was observed during stent deployment, signifying a critical embolic phase. No perioperative neurological complications or other significant adverse events were documented.

Conclusion: Transcranial Doppler, near-infrared spectroscopy, and bispectral index effectively monitor cerebral hemodynamics and embolic potential during transcarotid artery revascularization, providing real-time data crucial for optimizing perioperative management. These findings underscore the clinical value of multimodal monitoring in improving patient outcomes in transcarotid artery revascularization procedures.

Keywords : Carotid artery disease, cerebral hemodynamics, neuroprotection systems, transcarotid artery revascularization, transcranial Doppler
Viewed : 1384
Downloaded : 679