Methods: The study had been performed in Acıbadem Kadıköy Hospital during February 2011 and June 2011. Seventy patients who were admitted with coronary heart disease (CHD) and scheduled for coronary artery bypass graft (CABG) surgery were included in the study. The patients were divided into two equal groups. Thirty five percent of the 35 patients (n=12) were female in group 1, 50% of 50 patients (n=18) were female in group 2. The mean age was 60±10 years and 57±11 years in group 1 and group 2, respectively. Group 1 consisted of 35 patients with adjusted inspired oxygen fraction (FiO2) at 0.35-0.45 during CABG. Group 2 consisted of 35 patients with adjusted FiO2 at 0.40- 0.50 during surgery. In addition to the standard monitorization, cerebral cortical oxygen saturation of all patients was monitored by NIRS. The measurements were done five times during the course of CABG.
Results: In group 1, hypoxia was detected in five patients (14%) in at least one of the five measurement periods. In these patients, FiO2 value increased accompanied by increased ScO2. In group 2, hyperoxemia was observed in at least one of the measurement periods in 15 (42.8%) patients. Hypoxia was not observed in any of the patients in group 2.
Conclusion: It is possible to detect hypoxic periods and to adjust FiO2 accordingly by means of noninvasive cerebral cortical oxygen saturation measurement in nonpulsatile flow of CPB.
In order to avoid hyperoxemia and keep the partial oxygen level (pO2) <180 mmHg, the FiO2 should be lowered accordingly; however, some patients may then run the risk of hypoxia (pO2 < 80 m mHg). Thus, it is necessary to keep in mind the risk of hypoxia and take the necessary precautions to diagnose it when adjusting the FiO2.[9] In addition, preventing hyperoxia from occurring during coronary artery bypass grafting (CABG) is also crucial. If the perfusion during CABG is nonpulsatile, the efficacy of the pulse oximeter when attempting to diagnose hypoxia is reduced. However, near infrared spectroscopy (NIRS), which is unaffected by the nonpulsatile flow, provides useful knowledge about ischemic changes in the brain tissue by measuring regional cerebral oxygen saturation.
Hypoxemic attacks can occur during CABG while trying to refrain from hyperoxemia. In order to assess the effects of hypoxia episodes on cerebral perfusion during CPB as early as possible and make the necessary adjustments to the FiO2 in time, we aimed to detect the regional cerebral oxygen saturation with the help of NIRS monitorization and diagnose the hypoxemic or hyperoxemic episodes. Our goal was to keep the FiO2 at the lowest safe level by this noninvasive method of monitorization.
Group 1 consisted of 35 patients whose FiO2 would be 0.35 in the normothermic and hypothermic periods of CABG and 0.45 at the beginning of rewarming. Group 2 was composed of 35 patients whose FiO2 would be 0.40 in the normothermic and hypothermic periods of CABG and 0.50 at the beginning of rewarming (Table 1). In addition to the standard monitorization, cerebral cortical oxygen saturation (ScO2) of all the patients was monitored by NIRS through the INVOS Model 5100 C cerebral/somantic oximeter (Somanetics Corporation, Troy, Michigan, USA), and five measurements were taken with this device during CABG. The first was obtained before the induction of anesthesia (T1=basal), the second at the fifth minute of CPB (T2), the third at 15 minutes after cross-clamping (T3), the fourth after the cross-clamp had been removed (T4), and the fifth just before the end of extracorporeal circulation (T5).
A decrease in the ScO2 values of more than 20% from the basal value was accepted as significant. When there was a decrease of more than 20% from the basal value, an arterial blood gas analysis was done in addition to the what was planned in the five time periods, and the pO2 levels were kept above 90 mmHg. Furthermore, when the ScO2 levels decreased by more than 20% from the baseline and the pO2 levels were >90 mmHg, the pump blood flow and mean arterial pressure (MAP) were increased successively. Despite all these maneuvers, if there was no improvement in the ScO2 levels and the hematocrit was <20%, red blood cell transfusion were planned for the patients.
The INVOS monitor has a probe with two photodetectors and a light source which are placed on the right and left frontal hemispheres on the forehead. The photodetector closest to the light source absorbs the superficial rays (from skin, bone, and fat tissue), whereas the other photodetector absorbs the rays from the deep tissues of the brain. Oxymetric studies are based principally on the Beer-Lambert Law which states the following.p> A= -log(I1/I0)=al.C.L
A=attenuation; I1= detected light intensity; I0= incident light intensity; a= specific extinction coefficient (mM-1.cm-1); C= the molar concentration C of absorbing species in the material; L= distance light enters and leaves solution (cm).
In addition, the modified Beer-Lambert Law is used during the measurement of ScO2, in which the oxygen saturation values of the right and left hemispheres are stated as a percentage (%). When evaluated as biological spectroscopy, the INVOS oximeter emits a light that contains a light emitting diode (LED) at a wavelength of 660-940 nm. A light at this wavelength is absorbed strongly by oxyhemoglobin and deoxyhemoglobin and very weakly by water, bone, fat, and skin tissue. Therefore, this feature of the infrared light provides some beneficial knowledge. For instance, the differentiation between oxyhemoglobin and deoxyhemoglobin is made by a specific extinction coefficient value (mM-1.cm-1) which shows the absorption degree of masses that absorb light at a certain wavelength. The absorption degree of the oxyhemoglobin molecule of a light at a wavelength of 680 nm is 0.4 mM-1.cm-1, whereas the absorption degree of deoxyhemoglobin is 2.4 0mM-1.cm-1. This difference provides the distinction.
Anesthesia and operative technique
The night prior to the operation, all patients received
alprazolam 0.5 mg by mouth (PO), and midazolam
125 mg/kg intramuscular (im) was given 30 minutes
before the operation. A 16-gauge (G) intravenous (i.v.)
cannula was inserted into all patients in the operating
room, and induction of anesthesia was performed using
midazolam 50 mg/kg, pancronium 0.15 mg/kg, and
fentanyl 25 to 35 mg/kg. After endotracheal intubation,
50% oxygen (O2), 50% nitrous oxide (N2O), and 3-4%
desflurane were used for all hemodynamically stable
patients, but the desflurane and N2O were discontinued
at times of hemodynamic instability. Anesthesia
was maintained and muscle relaxation was achieved
through the use of midazolam and vecuronium, both
80 mg/kg/hr. Furosemide 0.5 mg/kg was also routinely
administered. A Dideco Compactflo Evo microporous,
hollow-fiber membrane oxygenator (Sorin Group Italia S.r.l.-Cardipulmonary Business Unit, Mirandola, Italy)
was used for extracorporeal circulation. The priming
solution for CPB included 900 ml Ringer’s lactate
solution, 150 ml 20% mannitol, and 60 ml sodium
bicarbonate (8.4%).
During CPB, the MAP and pump flow were kept
between 50-70 mmHg, and 2.2-2.5 L/m2, respectively.
Sweep gas flow was kept at 1.5 L·min-1.m-2, and
blood gas analyses were carried out with an ABL 700
analyzer (Radiometer Medical, Brønshøj, Denmark).
Tissue perfusion adequacy was monitored via venoarterial
carbon dioxide partial pressure difference
(P
The results were analyzed via a chi-square test
(or Fisher’s exact test where applicable), and the
independent samples t-test. Statistical analysis was
performed using the Statistical Package for the Social
Sciences (SPSS Inc., Chicago, Illinois, USA) version 10
software program. Values of p<0.05 were considered to
be statistically significant, and all data was presented as
mean ± standard deviation.
Table 2: The values of cerebral cortical oxygen saturation
Table 3: The change in partial pressure of O2 and CO2 in relation to the five time periods
Indeed, hyperoxemia is associated with many side effects. An excess level of PaO2 has been implicated in the deterioration of capillary flow, decreased cardiac index, increased systemic vascular resistance and hemolysis.[1,5,7] Moreover, in several investigations in which tissue oxygenation was studied, decreased oxygenation, sometimes even to hypoxic levels, together with signs of maldistribution of capillary flow were found as a response to hyperoxemia.[5,11-13] Another deleterious effect of hyperoxemia was reported by Pizov et al.[4] in which they determined there was a larger increase of proinflammatory cytokines in patients treated with 100% oxygen compared with the 50% oxygen group. A delayed recovery in patients treated with 100% oxygen was reported in our study. The use of a high FiO2 in the perioperative period of general surgical procedures was reported to be associated with increased surgical site infection.[14]
On the other hand, we have known for years that on reperfusion, oxygen is detrimental, yet we still have PaO2 rates of up to 300 or 375 mmHg when the cross-clamp is removed. Ihnken et al.[15] showed that hyperoxemic CPB during cardiac operations in adults results in oxidative myocardial damage related to oxygen-derived free radicals and N2O. In their prospective randomized double-blind study, hyperoxemic bypass resulted in higher levels of polymorphonuclear leukocyte elastase, creatine kinase, lactic dehydrogenase, antioxidants, malondialdehyde, and nitrate in coronary sinus blood. In addition, a reduction in lung vital capacity and forced expiratory volume in one second (FEV1) compared with normoxemic management was noted. The clinical reflections of these findings were a 57% longer duration of ventilator support and an extra day spent in the hospital.[15] In recent years, more data has been accumulated regarding the cardioprotective effect of lowering oxygen tension after aortic declamping on CPB.[16,17]
Hyperoxemia and hypoxia during CPB should be avoided because of the many disadvantages. During the rewarming period of CPB, the oxygen demand increases. Therefore, according to a study by Toraman et al.,[9] it is necessary to work with higher FiO2 values (PaO2 >80 mmHg) during hypothermia. If these higher values remain constant during CPB, it is inevitable that hyperoxia during hypothermia will occur. However, if the hypothermia period is used as a guide for FiO2 adjustment, then hypoxia during rewarming will take place. Hence, it is inappropriate to work with a constant FiO2 value during CPB. The evidence from the study by Toramal et al.[9] indicates that if FiO2 ratios are kept between 35-45%, the risk of hypoxia during rewarming and hyperoxemia during hypothermia are reduced. However, it is rare to observe hypoxemia with an FiO2 level of 0.35, a nd levels of 0.40 a re normally used in order to minimize the possibility of having inadequate levels of oxygen in the blood. Nevertheless, hyperoxemia occurred in 43% of the patients of the study by Toramal et al. This leads to the conclusion that increasing FiO2 levels does not solve this problem during hypothermia and that it would be safer to keep them at 0.35 instead of 0.40.
In order to diagnose and treat the hypoxic periods in timely manner, close monitorization is mandatory. For example, connecting the devices to the arterial part of the CPB so that blood gas analysis can be done online is beneficial, but the cost of this monitorization limits its widespread use. The use of high FiO2 values has become widespread for safety reasons. In our study, measurement of the ScO2 levels was used as a tool to diagnose systemic tissue hypoxia and as an alternative method to online blood gas analysis or use a pulse oximeter. When the ScO2 levels in our study were measured during CPB, hypoxia was detected in five of the patients in group 1 (14%), and they were treated by increasing the FiO2 level by 10%. In 80% of the patients in this group, no hyperoxemia period was detected, and the detected hypoxemic periods were treated. In group 2, there were hyperoxemia attacks during CPB in 43% of the patients.
We believe that measuring the levels of ScO2 in the nonpulsatile flow of CPB can be an effective noninvasive method of monitorization. If this occurs, it would allow for hypoxic periods to be detected and treated appropriately and on time. Additionally, our data revealed that the use of lower FiO2 values leads to less hyperoxemia during CPB.
Declaration of conflicting interests
The authors declared no conflicts of interest with respect
to the authorship and/or publication of this article.
Funding
The authors received no financial support for the
research and/or authorship of this article.
1) Anderson KJ, Harten JM, Booth MG, Kinsella J. The
cardiovascular effects of inspired oxygen fraction in
anaesthetized patients. Eur J Anaesthesiol 2005;22:420-5.
2) Thomson AJ, Webb DJ, Maxwell SR, Grant IS. Oxygen
therapy in acute medical care. BMJ 2002;324:1406-7.
3) Harten JM, Anderson KJ, Angerson WJ, Booth MG, Kinsella
J. The effect of normobaric hyperoxia on cardiac index in
healthy awake volunteers. Anaesthesia 2003;58:885-8.
4) Pizov R, Weiss YG, Oppenheim-Eden A, Glickman H,
Goodman S, Koganov Y, et al. High oxygen concentration
exacerbates cardiopulmonary bypass-induced lung injury.
J Cardiothorac Vasc Anesth 2000;14:519-23.
5) Joachimsson PO, Sjöberg F, Forsman M, Johansson M,
Ahn HC, Rutberg H. Adverse effects of hyperoxemia
during cardiopulmonary bypass. J Thorac Cardiovasc Surg
1996;112:812-9.
6) Chartrand C, Langevin L, Forest F, Stanley P. Hyperoxemia
in extracorporeal circulation. Can J Surg 1975;18:84-7.
[Abstract]
7) Brodie JE, Johnson RB. Conduct of perfusion. In: Halligan M,
Moore P, Richards K, Brodie J, editors. The manual of clinical
perfusion. 2nd ed. Georgia, USA: Glendale; 1997. p. 67-79.
8) Karabulut H, Toraman F, Tarcan S, Demirhisar O, Alhan
C. Adjustment of sweep gas flow during cardiopulmonary
bypass. Perfusion 2002;17:353-6.
9) Toraman F, Evrenkaya S, Senay S, Karabulut H, Alhan C.
Adjusting oxygen fraction to avoid hyperoxemia during
cardiopulmonary bypass. Asian Cardiovasc Thorac Ann
2007;15:303-6.
10) Parolari A, Alamanni F, Gherli T, Bertera A, Dainese
L, Costa C, et al. Cardiopulmonary bypass and oxygen consumption: oxygen delivery and hemodynamics. Ann
Thorac Surg 1999;67:1320-7.
11) Lund N, Jorfeldt L, Lewis DH, Odman S. Skeletal muscle
oxygen pressure fields in artificially ventilated, critically ill
patients. Acta Anaesthesiol Scand 1980;24:347-53.
12) Lund N, Jorfeldt L, Lewis DH. Skeletal muscle oxygen
pressure fields in healthy human volunteers. A study of
the normal state and the effects of different arterial oxygen
pressures. Acta Anaesthesiol Scand 1980;24:272-8.
13) Thorborg P, Gustafsson U, Sjöberg F, Harrison DK, Lewis
DH. Effect of hyperoxemia and ritanserin on skeletal muscle
microflow. J Appl Physiol 1990;68:1494-500.
14) Pryor KO, Fahey TJ 3rd, Lien CA, Goldstein PA. Surgical
site infection and the routine use of perioperative hyperoxia
in a general surgical population: a randomized controlled
trial. JAMA 2004;291:79-87.
15) Ihnken K, Winkler A, Schlensak C, Sarai K, Neidhart G,
Unkelbach U, et al. Normoxic cardiopulmonary bypass
reduces oxidative myocardial damage and nitric oxide during
cardiac operations in the adult. J Thorac Cardiovasc Surg
1998;116:327-34.