Coronary artery anomalies are rare, occurring in just 1.3% of the population. Most individuals are diagnosed incidentally, but in approximately 20% of patients, these anomalies may result in myocardial infarction, arrhythmia, and sudden death.[3] Anomalous coronary arteries are usually sporadic but may also be associated with congenital heart diseases and bicuspid aortic valves.
Herein, we present the case of a sinus of Valsalva aneurysm associated with an anomalous origin of the circumflex coronary artery in a patient with Peter’s syndrome that was successfully treated with the modified Tirone David-V procedure.
The operative procedure was performed through a median sternotomy using moderate hypothermic cardiopulmonary bypass (CPB). Following the aortotomy incision, the circumflex coronary artery (Cx) presented with an anomalous origin from the right coronary sinus that had a retroaortic and subannular path. The right coronary artery (RCA) and the Cx were then dissected as a whole button, and a 1 mm probe was placed within the Cx, which detected the subannular retroaortic course of the RCA (Figure 1). Next, we assessed whether the annular suture line was secure via the probe, and after examining the aortic valve, including the thickness and coaptation of each leaflet, V-SARR was accomplished using two individual 30 mm and 28 mm conduit grafts (Figure 1). First, the 30 mm Dacron conduit was implanted in the subannular position using pledgetted polypropylene sutures, and all three commissures were re-suspended inside the tube graft after determining the correct height and alignment. Then the aortic annulus and remnant sinuses are re-suspended within the tube graft with continuous 4/0 polypropylene sutures. After this, the 28 mm Dacron conduit was attached to the first conduit with continuous 4/0 polypropylene sutures after the edges were fashioned, and this was followed by the reimplantation of the coronary artery buttons to create neosinuses. The osteal opening was also examined. Thus, the aortic root implantation and reconstruction of the neosinuses was performed via the use of two Dacron conduits of different sizes. Anastomoses was completed via a de-airing procedure, and the cross-clamp was then removed. Weaning from CPB was uneventful, and intraoperative TEE revealed mild aortic valve regurgitation. The patient was extubated on postoperative day one and was subsequently discharged on postoperative day seven. The follow-up TTE and CT at the first month showed a successful repair of the sinus of Valsalva aneurysm and an intact coronary artery flow (Figure 2).
Although a separate annuloplasty can be performed during the remodeling procedure, it is already incorporated into the reimplantation technique. Kvitting et al.[1] reported in their series that the patients with the longest follow-up had undergone reimplantation of the aortic valve, and at the five-year follow up, over 95% had not undergone an aortic valve reoperation.
Our preferred method is the reimplantation of the aortic root because recent studies have reported that this procedure is ideal for young patients whose primary problem is an aortic root aneurysm.[2] The benefit of the reimplantation technique versus the remodeling technique is that the aortic annulus is more stabilized; therefore, the probability for late aortic insufficiency is lower. Theoretically, the creation of pseudosinuses produces more natural leaflet motion, minimizes systolic contact between the valve cusps and the Dacron graft, and reduces diastolic closing cusp stress, all of which may enhance long-term valve durability and maintain relatively normal coronary flow patterns.
Coronary anomalies can be classified as anomalies of origin and course, anomalies of the intrinsic coronary arterial anatomy, or anomalies of termination. The retroaortic course is the most common and is seen in up to 0.9% of the population, particularly in cases in which the left Cx arises from either the right sinus of Valsalva or the RCA.[3] While the retroaortic or prepulmonic course is considered to be “benign” or “nonmalignant”, Samarendra et al.[5] suggested that when the Cx arises from the contralateral sinus with a retroaortic course, it may result in a predisposition toward selective coronary atherosclerosis.
It is important to recognize the retroaortic course of the anomalous coronary artery in patients with aortic valve disease since this artery may be inadvertently compressed during aortic valve or aortic root surgery. As previously mentioned, our patient did not undergo coronary imaging, so the rare coronary anomaly was detected intraoperatively. A coronary probe was used to determine the appropriate and safe annular suture verge to avoid a possible coronary injury. Hence, despite the close proximity of the abnormal coronary to the aortic annulus at the non-coronary and left coronary scallops, a modified David-V procedure was performed successfully with minimal aortic regurgitation.
Valve-sparing aortic root replacement is a safe and effective surgical option for the management of aortic root aneurysms in young patients, and the challenging coronary anatomy should not preclude performing this procedure. We also recommend that routine conventional coronary angiography or multislice computed tomographic coronary angiography be performed preoperatively to delineate the coronary anatomy.
Declaration of conflicting interests
The authors declared no conflicts of interest with
respect to the authorship and/or publication of this
article.
Funding
The authors received no financial support for the
research and/or authorship of this article.
1) Kvitting JP, Kari FA, Fischbein MP, Liang DH, Beraud
AS, Stephens EH, et al. David valve-sparing aortic root
replacement: equivalent mid-term outcome for different
valve types with or without connective tissue disorder. J Thorac Cardiovasc Surg 2013;145:117-26.
2) David TE. How I do aortic valve sparing operations to treat
aortic root aneurysm. J Card Surg 2011;26:92-9.
3) Patel S. Normal and anomalous anatomy of the coronary
arteries. Semin Roentgenol 2008;43:100-12.