Methods: The data of 53 patients (30 boys, 23 girls; median age 6.5 years; range 3 to 19 years) who were performed transcatheter closure of VSD between September 2006 and April 2013 in a single center were retrospectively analyzed. Perimembranous (n=42) and muscular (n=11) VSDs with hemodynamic significance which were suitable for transcatheter closure were included in the study. Four different devices were used in the study: the perimembranous Amplatzer VSD occluder, muscular Amplatzer VSD occluder, ductal Amplatzer occluder I, and II.
< b>Results: Median body weight was 21.5 kg (range 13 to 87 kg). The ratio of successful closure was 92%. One patient died due to complete atrioventricular block five days after the procedure and one patient died due to cerebral hemorrhage one day after the procedure.
Conclusion: Transcatheter closure of VSDs is an efficient method in selective cases. However, occurrence of complete atrioventricular block is a major concern in this procedure. Surgery should be considered as the first treatment choice in perimembranous VSD. However, in selected patients, transcatheter approach can be used for defect closure when necessary measures are taken against possible complications.
Only those patients with a muscular or perimembranous VSD with a hemodynamically significant left to right shunt that was detected via a clinical examination and echocardiography were included in the study. Those with the following characteristics were excluded: (i) body weight <8 kg and age <3 years old, (ii) a non-aneurysmal perimembranous VSD (PMVSD) with a subaortic rim of <2 mm, (iii) pulmonary systolic pressure of >70 mmHg as identified by TTE, (iv) a right to left shunt, (v) sepsis, (vi) a defect associated with complex heart lesions (vii) a contraindication to antiplatelet therapy.
The four devices used in the study were the Amplatzer™ muscular VSD occluder (MVSDO), the Amplatzer™ PMVSDO, the Amplatzer™ duct occluder I (ADO I), and the Amplatzer™ duct occluder II (ADO II). The MVSDO was used in 11 patients with an MVSD. The PMVSDO was preferred for the 32 patients with a PMVSD. The ADO I device was used in the nine patients with an aneurysmatic PMVSD because it was suitable for the shape of the defect, and the ADO II device was used in one patient.
The catheterization procedure was carried out routinely under general anesthesia, and the patients were given antibiotics intravenously before the procedure. In addition, an electrocardiogram monitor was used throughout the procedure. The patients also initially received heparin 100 IU/kg, and additional doses were given when necessary to maintain an activated clotting time (ACT) of >200 seconds. The preferred vascular access sites were the right femoral vein and the left femoral artery. Left ventriculography in the left anterior oblique view was used to show the location and size of the VSD and then the procedure was performed with fluoroscopic and transesophageal echocardiographic (TEE) guidance. The size of the VSD size was measured on the right ventricular side, and a ventricular septal aneurysm was present in 15 of the patients with a PMVSD (35%). In these cases, the size was also measured on the right ventricular side and at the narrowest part. The appropriate device size was chosen to be at least 1 to 2 mm larger than the VSD size as measured at the largest diastolic phase by color Doppler TEE or ventriculography. A 4 or 5 French (F) right Judkins catheter or a partially cut pigtail catheter was then passed through the VSD. Afterwards, a hydrophilic guidewire was passed across the defect into the right ventricle and on into the pulmonary artery or superior vena cava (SVC) where it was snared and withdrawn from the femoral vein. Thus, an arteriovenous loop was established. Subsequently, a long sheath (6-12F) was advanced into the left ventricle via the arteriovenous circuit. An occluder was then inserted into the delivery sheath and positioned on the VSD. If the device position was satisfactory according to the fluoroscopy and TEE, the device was released. After the procedure, the position of the occluder was assessed via TEE and left ventriculography. The arterial approach was used in only two patients with PMVSDs. All of the patients were followed up with continuous electrocardiography (ECG) monitoring during the first 24 hours after the procedure and were discharged within five days of the procedure. Acetylsalicylic acid (5 mg/kg/daily) was administered to all patients for six months, and physical examinations, ECG, and TTE were performed at the postprocedural first, third, sixth, and 12th months and yearly thereafter. Furthermore, 24-hour Holter monitoring was performed three months after the procedure.
Shapiro-Wilk’s and Levene’s tests were used to assess the normality and changes in homogeneity of the data. Values were expressed as frequencies and percentages, mean ± standard deviation (SD), or median and 25th-75th percentiles due to the normality and variable type of the data. To compare the defects, device sizes and defects/device sizes were used, and for all statistical analyses, a p value of <0.05 was considered to be statistically significant. All analyses and calculations were done using the SPSS for Windows, Version 15.0 software program (SPSS Inc., Chicago, IL, USA).
Furthermore, one patient underwent a pulmonary banding operation, two had mild pulmonary stenosis, two had mild mitral regurgitation, one had patent ductus arteriosus, one had a VSD with a residual shunt and had previously surgery for this. Additionally, an Amplatzer™ Septal Occluder was used to close an atrial septal defect (ASD) in another patient. The VSD closure was successful in 49 patients (92%), but it failed in four others. In one patient, the device was retrieved because we were unable to achieve a good device position via ADO I, and transient complete atrioventricular block (AVB) occurred in another. Therefore, we ended the procedure, and normal sinus rhythm returned after one hour. In another patient, the device was embolized in the femoral artery during the PMVSD closure via ADO I, and in the fourth patient, the device was embolized in the left pulmonary artery during the PMVSD closure using PMVSDO. The embolized devices were then captured by a snare catheter and retracted into the delivery system.
Unfortunately, two patients died (3.8%) due to severe complications. In a four-year-old boy whose VSD had been closed with a 6 mm PMVSDO, complete AVB occurred four days after the procedure. This condition had not been observed during t he two-day follow-up period in t he hospital, so the patient had been discharged. He had syncope four days after transcatheter closure. He also had bradycardia with a heart rate of 36 beats/min. Electrocardiography revealed the complete AVB, and even though a transient transvenous pacemaker was implanted immediately in the patient, he did not survive. The other patient was a three-year-old girl whose 4 mm VSD was closed with a 6 mm PMVSDO. On the second day, she suddenly lost consciousness, and a cerebrovascular aneurysm and cerebral hemorrhage were detected via computed tomography (CT). The patient was not under the prophylactic heparin treatment; therefore, this intracranial hemorrhage was thought to be due to the cerebrovascular aneurysm. Despite all of our efforts, she a lso did not survive.
In one patient, a rupture of the chordae tendineae caused mitral insufficiency, but the patient remained asymptomatic. In another patient, right bundle branch block (RBBB) developed following the procedure, but in the other patients, the BBBs were tolerated well after the VSD closure. All of the complications are summarized in Table 2.
The complete closure rate was almost perfect at 98%, but one patient experienced a mild residual defect after the procedure. During the procedure, no deaths, cardiac perforations, or cerebrovascular events occurred, and no femoral artery damage, femoral artery thrombosis, inguinal hematomas, or brachial palsy-like complications were noted. Moreover, during the follow-up period, no additional complications, such as late AVB, were encountered.
Our statistical analysis showed that the mean defect size of the 49 patients who had successful VSD closure was 4.3±0.2 mm, whereas the mean defect size of the four whose attempted VSD closure failed was 6.7±0.7 mm. The mean age of the seven patients who developed procedure-related complications was 4.8±0.9 years, and their mean body weight was 17.1±2.6 kg. The mean age of the patients without complications was 8.4±3.1 years, and their mean body weight was 28.7±3.1 kg. The defect size of the two patients who did not survive was 4 mm and the device size was 6 mm, whereas the defect size of the patients without complications was 4.6±1.5 mm and their device size was 6±1.5 mm. All of the complications occurred in the PMVSD cases (7/42; 16%), but no complications occurred in the MVSD cases (0/11; 0%) (p=0.322). Furthermore, all four of the unsuccessful VSD closure cases also involved patients with PMVSD, but there were no statistically significant differences with regard to these results.
In this report, a single-center experience involving the transcatheter closure of VSDs was presented. Other studies have reported a successful closure rate for this procedure of between 91 and 100%.[13-15] In our series, the success rate for implantation was 92%, and we saw only one procedural complete AVB, which was transient. However, Zhou et al.[16] reported two cases of complete AVB in their study. In addition, device embolizations occurred in two of their cases, and the device was removed percutaneously in a catheterization laboratory. In both of these cases the embolization could have been caused by the small size of the devices. Moreover, Holzer et al.[13] reported two device embolization cases in 75 MVSD patients in their study.
In two other studies, significant early complications occurred in two patients (3.8%), and complete AVB developed in approximately 1% of the patients who underwent surgical repair for the VSDs.[17,18] In the study by Tucker et al.,[18] they determined that Down syndrome (DS) was the most significant risk factor for postsurgical complete AVB. Additionally, some studies have reported an incidence rate for complete AVB of between 0 and 5.7% for patients who undergo transcatheter device closure of VSDs.[13-15] In our study, permanent complete AVB only was seen in one case (1.9%) with a PMVSD, and this did not occur until four days after the procedure. After the death of this patient, we monitored each patient for five days after they underwent non-aneurysmal PMVSD closure.
Complete AVB is a major complication that can occur both during and after transcatheter closure of a PMVSD, and it develops because of the close proximity of the PMVSD to the conduction system.[16] In these cases, the device may interfere with atrioventricular conduction via direct compression trauma, or it may provoke an inflammatory response or cause scarring in the conduction tissue. Particularly in patients who are under three years old, the immaturity of their conduction system means the risk of complete AVB development is much higher. Zuo et al.[9] found that complete AVB is more common (18.2%) in this age group, with the risk for patients over three years of age being just 4.7%. However, our statistical analysis did not reveal any variable that could predict the occurrence of complete AVB in our patients.
In our series, the median follow-up was 32 months, and no late complete AVB was noted. However, complete AVB usually appears soon after surgical repair. In patients treated percutaneously, the occurrence of complete AVB is quite unpredictable, and it is usually seen later.[11] Because of this, careful monitoring of heart rhythm is essential during followup, especially in those subjects treated for a PMVSD. It is hard to estimate when complete AVB will occur in the late term; therefore, Holter monitoring is vitally important in the postprocedural first, third, and sixth months. It is also necessary to teach parents how to count the pulse rate so that they can seek immediate care at a third-level health center in cases of syncope and presyncope. This training is especially valuable for the early management of events before the development of irreversible changes. Some authors[9,11] have suggested that a course of steroids should be used to treat AVB, but we believe that the best course of action is prompt device removal for patients who develop complete AVB during the procedure.
A cerebral hemorrhage was seen on CT 24 hours after the procedure in a three-year-old girl in our study, and Yang et al.[19] reported one death due to an unexplained cerebral hemorrhage. Like Yang et al.,[19] we believe that this situation might have been caused by a cerebrovascular malformation.
Mild mitral insufficiency developed in one of our patients due to chordae tendineae rupture, and Yang et al.[19] reported three cases of new-onset mitral insufficiency that required surgery.
The mean defect size in the four patients for whom the VSD closure failed in our study was larger than that of the patients who experienced successful closure. Furthermore, the mean age and weight of the patients with complications were less than those for the patients without complications, and these expected results were in compliance with the literature.[9] The reason for the statistical insignificance in our study seemed to stem from the limited number of patients since we could find no association between the development of complications and the defect size or defect/device ratio.
Declaration of conflicting interests
The authors declared no conflicts of interest with
respect to the authorship and/or publication of this
article.
Funding
The authors received no financial support for the
research and/or authorship of this article.
1) McDaniel NL, Gutgesell HP. Ventricular septal defects.
In: Allen HD, Driscoll DJ, Shaddy RE, Feltes TF, editors. Moss and Adams’ Heart Disease in Infants, Children, and
Adolescents. 7th ed. Philadelphia: Lippincott Williams &
Wilkins, a Wolter Kluwer business; 2008. p. 667-82.
2) Thanopoulos BV, Rigby ML, Karanasios E, Stefanadis
C, Blom N, Ottenkamp J, et al. Transcatheter closure of
perimembranous ventricular septal defects in infants and
children using the Amplatzer perimembranous ventricular
septal defect occluder. Am J Cardiol 2007;99:984-9.
3) Lillehei CW, Cohen M, Warden HE, Ziegler NR, Varco
RL. The results of direct vision closure of ventricular
septal defects in eight patients by means of controlled cross
circulation. Surg Gynecol Obstet 1955;101:446-66.
4) Fu YC, Bass J, Amin Z, Radtke W, Cheatham JP, Hellenbrand
WE, et al. Transcatheter closure of perimembranous
ventricular septal defects using the new Amplatzer
membranous VSD occluder: results of the U.S. phase I trial.
J Am Coll Cardiol 2006;47:319-25.
5) Şahin MA, Güler A, Cingöz F, Günay C, Yokuşoğlu
M. Ventriküler septal defekt tamir ameliyatında kordal
ayrıştırma yöntemi. Turk Gogus Kalp Dama 2012;20:636-7.
6) Lock JE, Block PC, McKay RG, Baim DS, Keane JF.
Transcatheter closure of ventricular septal defects. Circulation
1988;78:361-8.
7) Arora R, Trehan V, Kumar A, Kalra GS, Nigam M.
Transcatheter closure of congenital ventricular septal
defects: experience with various devices. J Interv Cardiol
2003;16:83-91.
8) Fu YC. Transcatheter device closure of muscular ventricular
septal defect. Pediatr Neonatol 2011;52:3-4.
9) Zuo J, Xie J, Yi W, Yang J, Zhang J, Li J, et al. Results of
transcatheter closure of perimembranous ventricular septal
defect. Am J Cardiol 2010;106:1034-7.
10) Mercan AŞ, Akay T, Aşlamacı S, Tokel K, Varan B,
Saygılı A. İnfant ventriküler septal defekt cerrahisinde risk
faktörleri. Turk Gogus Kalp Dama 2001;9:149-52.
11) Butera G, Carminati M, Chessa M, Piazza L, Micheletti A, Negura DG, et al. Transcatheter closure of perimembranous
ventricular septal defects: early and long-term results. J Am
Coll Cardiol 2007;50:1189-95.
12) Bol-Raap G, Weerheim J, Kappetein AP, Witsenburg M,
Bogers AJ. Follow-up after surgical closure of congenital
ventricular septal defect. Eur J Cardiothorac Surg
2003;24:511-5.
13) Holzer R, Balzer D, Cao QL, Lock K, Hijazi ZM. Device
closure of muscular ventricular septal defects using the
Amplatzer muscular ventricular septal defect occluder:
immediate and mid-term results of a U.S. registry. J Am Coll
Cardiol 2004;43:1257-63.
14) Carminati M, Butera G, Chessa M, Drago M, Negura D,
Piazza L. Transcatheter closure of congenital ventricular
septal defect with Amplatzer septal occluders. Am J Cardiol
2005;96:52-58.
15) Handke R, Jux C, Schranz D, Schneider M. Transcatheter
closure of perimembranous ventricular septal defects
using umbrella devices. Catheter Cardiovasc Interv
2006;68:936-41.
16) Zhou T, Shen XQ, Zhou SH, Fang ZF, Hu XQ, Zhao YS, et
al. Atrioventricular block: a serious complication in and after
transcatheter closure of perimembranous ventricular septal
defects. Clin Cardiol 2008;31:368-71.
17) Andersen HØ, de Leval MR, Tsang VT, Elliott MJ, Anderson
RH, Cook AC. Is complete heart block after surgical closure
of ventricular septum defects still an issue? Ann Thorac Surg
2006;82:948-56.