Methods: Between March 2006 and November 2012, 18 consecutive patients (14 males, 4 females; mean age was 61.9±11 years; range 39 to 77 years) who underwent TEVAR for acute complicated type B aortic dissection in our clinic were included in this study. Computed tomography scans obtained at the final visit were used for the volume analysis of true and false lumens. The median follow-up was 35.3 (range, 12 to 84) months. Indications for intervention were rupture or malperfusion in 17 patients (both in some patients) and persistent chest pain in one patient. The stent-graft part of the descending thoracic aorta (DTA) was defined as Segment 1, DTA without stent-graft (supraceliac) as Segment 2, and the abdominal aorta as Segment 3.
Results: In segment 1, the mean volume of true lumen increased from 74.4±49 mL to 110±50 mL (p=0.0145), while the mean volume of false lumen decreased from 124.2±81 mL to 59.5±59 mL (p<0.00001). In segment 2, the mean volume of true lumen increased from 23.1±28 mL to 40.5±33 mL (p=0.0015), while the mean volume of false lumen decreased from 32.8±29 mL to 29±1 mL (p=0.624). In segment 3, the mean volume of true lumen increased from 46.5±63 mL to 57.3±74 mL (p=0.0388), the mean volume of false lumen decreased from 41.8±30 mL to 37.6±32 mL (p=0.5195). True and false lumens volume changes were statistically significant except volume decrease in segment 3.
Conclusion: Endovascular repair of type B aortic dissection may positively affect aortic remodeling in chronic settings and may prevent possible aorta-related complications during longterm follow-up.
In the long-term period, the main causes of hospital admissions for this patient population include FL aneurysms and ruptures. In non-complicated group, which can be managed medically, FL aneurysms requiring intervention range between 20 and 50% over five years.[3-5] In complicated group, on the other hand, which has been already treated with endovascular or open techniques, the risk of an aneurysm formation outside of the treated segment is lower than the noncomplicated group.[6] The diameter or lumen volume has been assessed to analyze the aortic remodeling by several authors to predict the complication risk due to FL aneurysms.[4,7-10]
In this study, we aimed to analyze the volume changes of TL and FL at a late stage in patients who underwent thoracic endovascular aortic repair (TEVAR) due to acute complicated type B aortic dissection.
Table 1: Preoperative characteristics of patients
Thoracic endovascular aortic repair procedure was performed under general anesthesia in a hybrid operating room. Single femoral artery exploration was done in 16 patients and iliac artery in two patients due to the small size of the femoral artery. For pigtail catheter angiography, the ascending aorta was catheterized by axillary or brachial artery site. The mean diameter of stent-grafts (W.L.Gore & Associates, Inc. Flagstaff, AZ, and USA) was 33 mm (range, 26 to 40 mm). The decision of graft diameter was made according to the expected landing zone diameter. Oversizing strategy for the graft selection was not used. If zone 2 was a landing zone, rapid ventricular pacing was used to prevent graft migration due to the blood pressure effect. In other zones, graft implantation was done under controlled low blood pressure with medical therapy.
Computed tomography angiography continuous scans showing the entire aorta, including the proximal supra-aortic vessels to the femoral artery bifurcation, were obtained using a dual source 64-section multidetector CT scanner (Somatom Definition AS, Siemens Healthcare, Erlangen, Germany) with the following scanning parameters: 250 mAs, 120 kV, pitch 1, 1 mm reconstruction interval, and 1 mm reconstruction section thickness. An iodinated contrast agent (120 to 140 mL) was continuously injected using an automatic injector (Missouri, Ulrich Medizintechnik, Ulm, Germany) through the catheter in the antecubital vein at a rate of 4 mL/s. To ensure the maximum aortic contrast concentration, a circular region of interest was placed in the ascending aorta (threshold value: 120 HU). The raw data were transferred to an independent workstation to calculate volumes (Syngo version V35, Siemens Healthcare, Erlangen, Germany).
Preoperative examination was done on the same day or a day before the procedure. Postoperative examinations were carried out in accordance with the follow-up scheme of TEVAR procedure.
All CT scans were analyzed by a single radiologist. Descending thoracic aorta (DTA) starting from the origin of left subclavian artery to the iliac bifurcation was divided into three segments. The stent-graft placed part of DTA was defined as Segment 1, DTA without stent-graft (supraceliac) as Segment 2, and the abdominal part of the aorta as Segment 3.
The presence of thrombosis in each segment, whether partial or complete, was recorded. From the corrected axial plan image using the multi-planar reconstruction (MPR) technique, the areas of TL and FLs in each centimeter of aorta were measured. The volume calculation was made by addition of areas (sum of areas technique) measured in each 1 cm segment. The TL and FL volumes of each segment were calculated separately (Figure 1). Total FL volume was calculated as the volume of the perfused FL plus the volume of the thrombosed FL. In addition to the mean volume changes, we also documented the number of patients with increased or decreased volumes or volume stagnation of the TL and FL.
Statistical analysis
Statistical analysis was performed using the SPSS
version 16.0 software package (SPSS Inc., Chicago, IL,
USA). Continuous variables are presented in median
± standard deviation, while categorical variables
are given as expressed in number and percentage.
Continuous variables were analyzed using a paired
t test. A p value of <0.05 was considered statistically
significant.
In segment 1, the mean volume of TL increased from 74.4±49 mL to 110±50 mL (p=0.0145), while the mean volume of FL decreased from 124.2±81 mL to 59.5±59 mL (p<0.00001). The FL was completely thrombosed and volume of FL decreased in all patients (Figure 2). On the other hand, TL volume increased in 13 patients (72.2%), while three patients with a previous history of TL aneurysm had decreased volumes.
In segment 2 (supraceliac segment of DTA, without stent-graft), the mean volume of TL increased from 23.1±28 mL to 40.5±33 ml (p=0.0015), while the mean volume of FL decreased from 32.8±29 mL to 29±1 mL (p=0.624). Total thrombosis and partial thrombosis were achieved in seven and five patients, respectively. The TL volume increased in 14 patients (77.7%), whereas two of remaining showed a slight decrease of TL volume. The FL volume decreased in five patients (27.7%), while the volume increased in five patients (27.7%) (Figure 3).
In segment 3 (infraceliac part of abdominal aorta without stent-graft), the mean volume of TL increased from 46.5±63 mL to 57.3±74 mL (p=0.0388), while the mean volume of FL decreased from 41.8±30 mL to 37.6±32 mL (p=0.5195). The FL was thrombosed completely in only two patients and partially in four patients. The TL volume increased in nine patients (50%), whereas it decreased in one patient, and remained unchanged in eight patients (44.4%). The FL volume decreased in eight patients (44.4 %), while it increased in four patients (22.3%) (Table 2).
When Segment 2 was evaluated in conjunction with Segment 3, the mean volume of TL increased from 69.6±28 mL to 97.8±33 mL (p=0.0009). The mean volume of FL decreased from 74.5±30 mL to 66.1±28 mL (p=0.377). The mean volume of TL increased in 13 patients (72.2%), decreased in one patient (5.6%), remained unchanged in four patients (22.2%). The FL volume decreased in seven patients (38.8%), increased in four patients (%22.4), and remained unchanged in seven patients (38.8%) (Table 2).
In the stented aortic segment, the decrease in FL volume and the increase in TL volume were statistically significant. In the segment distal to the stent-graft (segments 2+3), the increase in TL was statistically significant; however, the decrease in FL volume reached no statistical significance (Figures 4, 5).
From the perspective of visceral complications, a patient presented with liver abscess before TEVAR due to hepatic ischemia and was drained by catheterization and treated with antibiotherapy. The patient who was dialysis-dependent before TEVAR experienced a significant improvement of the renal function after the procedure, which led to dialysis discontinuation. Acute pancreatitis was detected postoperatively in another patient with visceral malperfusion and resolved with medical therapy. None of the patients underwent ischemic causesrelated bowel resection. A patient with history of mesenteric ischemia due to dissection presented with brid ileus and underwent laparotomy two months after TEVAR.
The median stay in the intensive care unit was 36 hours. Three patients who had hemodialysis preoperatively had recovery of renal function. Four patients had gastrointestinal complications which did not require bowel resection. Operative mortality was seen in none of the patients. There was no late rupture in thoracic aorta. Rupture of infra-renal segment of the abdominal aorta was seen only in a patient at 22 months after TEVAR and treated with endovascular technique. Neurological complications such as paraplegia or stroke were not observed. All patients survived and no procedure-related event requiring an intervention occurred, until the date of study design.
One of the causes of mortality for chronic type B aortic dissection in the long-term is the formation of an aneurysm in FL and related ruptures. The incidence of this fatal complication is about 20-50% and requires intervention.[3] Previous studies showed that complete FL thrombosis was a predictor of reduced aortic enlargement and dissection-related mortality.[14] In such cases, TEVAR is an option; however, membrane dissection becomes less elastic which cannot be compressed by the expansion of the stent-graft in chronic settings. Kim et al.[9] evaluated the volume changes in patients with acute complicated type B aortic dissection who were treated with endovascular stent-graft and they found a progressively increased TL volume and decreased FL volume in the absence of an endoleak. Similarly, in a comparative study, Huptas et al.,[15] demonstrated that aortic remodeling was stronger with TEVAR than medical therapy in non-complicated group, even. In our study, we found a significant increase of TL volume in all three segments of the aortic dissection. However, the decrease of FL volume in the abdominal segment of aorta was not found to be significant. In the INSTEAD trial analyzing the impact of TEVAR in acute type B aortic dissection, the authors showed a significant progression of TL and regression of FL, despite no benefit on survival at two years.[12] In our study, the aortic volume changes did not affect survival.
Another criterion for aortic remodeling is FL patency. In patients with chronic type B aortic dissection who are followed with medical treatment, spontaneous thrombosis in FL is extremely rare. In almost 80% of these patients, there was an increased FL volume. Tsai et al.[16] reviewed the International Registry of Acute Aortic Dissection (IRAD) to assess the possible relationship between FL patency and mortality in acute type B aortic dissection. The authors found that partial thrombosis of FL had a higher mortality rate than complete patency. Therefore, aortic remodeling which targets the complete thrombosis of FL, resulting in TL expansion should be achieved. After TEVAR, FL thrombosis is only limited with the stented thoracic aorta segment. However, spontaneous thrombosis of FL is extremely rare and total aortic volume usually increases with a high-risk of rupture in patients with chronic type B aortic dissection on medical treatment.[15] As a result, closure of the proximal intimal tear by aortic stentgrafting and ensuring the thrombosis of FL in the stented segment may return the flow to its previous stance and cause aortic remodeling by ameliorating the flow in visceral arteries. Also, this process is not limited to the early stage after TEVAR and continues in the late stage, as well. In addition, self-expandable stent-grafts have a positive impact on the expansion of TL and compression of FL. From this point of view, we achieved total thrombosis of FL at the stented segment in all patients immediately after TEVAR procedure. Complete thrombosis of FL in Segment 2 and 3 was also achieved in seven and two patients, respectively. However, thrombosis was not seen in six patients for Segment 2 and in nine patients for Segment 3. In one patient, FL aneurysm and rupture due to resistant flow in the abdominal segment was observed and these were treated with endovascular method. The rates of FL thrombosis distal to the stent graft were particularly poor, indicating that a long length of aortic coverage is required to gain better FL thrombosis and aortic remodeling.
Furthermore, there is currently no consensus on the optimal pathway to measure or report aortic changes after TEVAR. Volumetric measurement of the aorta due to the altered shape of TL and FLs seems to be more appropriate to assess the aortic remodeling.[4] In this study, volumetric measurement of the dissected segment of the aorta through highly sensitive CT scan was used to evaluate the aortic remodeling due to the altered shape of the lumen structure. Although the diameter analysis has been done in recent studies,[4,7] some authors claimed that uni-dimensional diameter analysis of the dissected aorta provides inaccurate data to predict the risk of rupture.[5,15] Another twilight zone for TEVAR is the length of aortic coverage with the stent-graft. Extensive implantation of an endograft for FL thrombosis may increase the risk for spinal injury after TEVAR. In a review, Nienaber and Eagle[17] emphasized that the graft implantation which did not exceed 18 cm had a low risk for paraplegia. In this cohort, the mean length of aortic coverage was found to be 17.5 cm. Therefore, we believe that postoperative neurological events were not seen in any patient, despite cerebrospinal fluid drainage was not used.
On the other hand, this study has some limitations. Firstly, we had a small sample size. Secondly, the retrospective design of the study precluded a thorough investigation. Thirdly, we did not have a comparison group to make a comprehensive comparison of two techniques.
In conclusion, endovascular repair of type B aortic dissection may cause an expected aortic reverse remodeling which prevents aorta-related complications in the long-term.
Acknowledgement
We are thankful to Merve Evren for the medical
illustrations.
Declaration of conflicting interests
The authors declared no conflicts of interest with
respect to the authorship and/or publication of this
article.
Funding
The authors received no financial support for the
research and/or authorship of this article.
1) Estrera AL, Miller CC, Safi HJ, Goodrick JS, Keyhani A,
Porat EE, et al. Outcomes of medical management of acute
type B aortic dissection. Circulation 2006;114:384-9.
2) Fattori R, Cao P, De Rango P, Czerny M, Evangelista
A, Nienaber C, et al. Interdisciplinary expert consensus
document on management of type B aortic dissection. J Am
Coll Cardiol 2013;61:1661-78.
3) Duson SM, Crawford RS. The role of endografts in the
management of type B aortic dissections. Perspect Vasc Surg
Endovasc Ther 2012;24:177-83.
4) Conrad MF, Crawford RS, Kwolek CJ, Brewster DC, Brady
TJ, Cambria RP. Aortic remodeling after endovascular repair
of acute complicated type B aortic dissection. J Vasc Surg
2009;50:510-7.
5) Rodriguez-Lopez JA, Diethrich EB. Diameter or volume?
The measure of success after endovascular repair of thoracic
aortic dissections. J Endovasc Ther 2009;16:39-41.
6) Song TK, Donayre CE, Walot I, Kopchok GE, Litwinski RA,
Lippmann M, et al. Endograft exclusion of acute and chronic
descending thoracic aortic dissections. J Vasc Surg
2006;43:247-58.
7) Rodriguez JA, Olsen DM, Lucas L, Wheatley G, Ramaiah
V, Diethrich EB. Aortic remodeling after endografting of
thoracoabdominal aortic dissection. J Vasc Surg 2008;47:1188-94.
8) Schoder M, Czerny M, Cejna M, Rand T, Stadler A, Sodeck
GH, et al. Endovascular repair of acute type B aortic
dissection: long-term follow-up of true and false lumen
diameter changes. Ann Thorac Surg 2007;83:1059-66.
9) Kim KM, Donayre CE, Reynolds TS, Kopchok GE, Walot I,
Chauvapun JP, et al. Aortic remodeling, volumetric analysis,
and clinical outcomes of endoluminal exclusion of acute
complicated type B thoracic aortic dissections. J Vasc Surg
2011;54:316-24.
10) Andacheh ID, Donayre C, Othman F, Walot I, Kopchok G,
White R. Patient outcomes and thoracic aortic volume and
morphologic changes following thoracic endovascular aortic
repair in patients with complicated chronic type B aortic
dissection. J Vasc Surg 2012;56:644-50.
11) Walker PJ, Dake MD, Mitchell RS, Miller DC. The use of
endovascular techniques for the treatment of complications
of aortic dissection. J Vasc Surg 1993;18:1042-51.
12) Nienaber CA, Rousseau H, Eggebrecht H, Kische S, Fattori
R, Rehders TC, et al. Randomized comparison of strategies
for type B aortic dissection: the INvestigation of STEnt
Grafts in Aortic Dissection (INSTEAD) trial. Circulation
2009;120:2519-28.
13) Brunkwall J, Lammer J, Verhoeven E, Taylor P. ADSORB:
a study on the efficacy of endovascular grafting in
uncomplicated acute dissection of the descending aorta. Eur
J Vasc Endovasc Surg 2012;44:31-6.
14) Marui A, Mochizuki T, Mitsui N, Koyama T, Kimura F,
Horibe M. Toward the best treatment for uncomplicated
patients with type B acute aortic dissection: A consideration
for sound surgical indication. Circulation 1999;100:275-80.
15) Huptas S, Mehta RH, Kühl H, Tsagakis K, Reinsch
N, Kahlert P, et al. Aortic remodeling in type B aortic
dissection: effects of endovascular stent-graft repair and
medical treatment on true and false lumen volumes. J
Endovasc Ther 2009;16:28-38.