ISSN : 1301-5680
e-ISSN : 2149-8156
Turkish Journal of Thoracic and Cardiovascular Surgery     
Transkateter aortik kapak implantasyonun sonrasında femoral arter tamiri için vasküler kapama cihazı ile konvansiyonel cerrahinin karşılaştırması
Mehmet Beşir Akpınar1, İlker Gül2, Veysel Şahin1, Ahmet Taştan2, İhsan Sami Uyar1, Halil Uç1, İlker Kiriş1, Faik Fevzi Okur1
1Departments of Cardiovascular Surgery, Medical Faculty of Şifa University, İzmir, Turkey
2Departments of Cardiology, Medical Faculty of Şifa University, İzmir, Turkey
DOI : 10.5606/tgkdc.dergisi.2016.12821

Abstract

Background: This study aims to compare the results of a percutaneous closure device versus conventional surgery for femoral artery access site closure during transcatheter aortic valve implantation.

Methods: Between June 2013 and September 2015, a total of 111 consecutive patients (56 males, 55 females; mean age 77.7±7.4 years; range, 52 to 95 years) who underwent transcatheter aortic valve implantation via transfemoral artery access were included in the study. Femoral artery access site was closed by a percutaneous closure device in 67 patients (60.4%) and by conventional surgery in 44 patients (39.6%). Safety and efficiency of both techniques were assessed in terms of the complications, re-interventions, and re-hospitalizations during the postoperative 30 days.

Results: Four patients (6%) experienced technical complications with the percutaneous closure device. A total of 53 (79.1%) patients in the percutaneous closure device group and 42 (95.5%) patients in the conventional surgery group achieved technical success without any need for re-intervention. A significantly higher number of percutaneous closure device patients experienced total vascular complications [22 (32.9%) vs 5 (11.4%); p=0.012] and needed secondary vascular interventions [12 (17.9%) vs 2 (4.6%); p=0.043], [emergency surgical intervention 2 (3%), percutaneous balloon angioplasty 12 (17.9%), and graft-stent implantation 7 (10.4%)], compared to the conventional surgery group. However, the rate of postprocedural wound complications, including lymphorrhea and infection, was higher [15 (34%) vs 6 (9%)] and the length of hospital stay was longer in conventional surgery group (4.7±1.2 vs 4.2±1.6 days; p=0.04).

Conclusion: Our study findings suggest that conventional surgery is more effective and safer than the percutaneous closure device for femoral artery access site closure during transcatheter aortic valve implantation procedures with a lower rate of periprocedural complications and re-interventions. In contrast, femoral artery access site closure by a percutaneous closure device seems to be associated with less postprocedural wound site complications than conventional surgery.

As catheter-based endovascular approaches have increased, the transcatheter aortic valve implantation (TAVI) procedure has become more widespread. The common femoral artery is often used as a catheter access region in the TAVI procedure. In recent years, percutaneous closure devices (PCD) have been increasingly used to close the arterial access site.[1-4]

Currently, PCDs developed for percutaneous approaches work with a system known as ‘preclose’, which is used to close the percutaneous catheter puncture sites with a diameter of ≥10 French.[5] Within this system, a catheter of 10F diameter is first used, and, then, the entry hole of this catheter is dilated for wider catheters. Around these catheters, there are two cross-over sutures and there are four needles at the end of these sutures. During the procedure, these needles pull on the vessel, and, then, the needles are pulled out, piercing the artery around the puncture site. In this way, the ends of the two sutures which pass diagonally across the puncture sites are drawn outside the arterial wall.[6] With the percutaneous approach, smaller surgical wounds, quicker patient mobilization and a shorter in hospital stay are predicted, compared to the surgical preparation.[7] The surgical preparation for endovascular approaches by catheter from the groin carries risks such as bleeding, lymphorrhea, infection of the wound site, and prolonged hospital stay.[5-7] When the procedure with a PCD fails, arterial injury, dissection, bleeding, thrombosis, pseudoaneurysms, and late pseudoaneurysms may develop, thereby, bearing a need for additional intravascular catheter interventions or surgical interventions.[8-10] In our clinic, both conventional surgery (CS) and percutaneous approaches are used in TAVI procedures. In the percutaneous approach, a Prostar® XL PCD (Prostar XL Percutaneous Vascular Surgical Device, Perclose ProGlide Suture- Mediated Closure System, Abbott Vascular, Santa Clara, CA, USA) is used.

In this study, we aimed to compare the results of a PCD versus CS for femoral artery access site closure during TAVI.

Methods

This retrospective, observational, single-center study included a total of 111 patients (56 males, 55 females; mean age 77.7±7.4 years; range, 52 to 95 years) who underwent TAVI between June 2013 and September 2015. Patients who were ineligible for an iliofemoral artery system catheter approach, patients who intraoperatively died due to aortic root rupture, dislocation of the prosthetic valve into the ventricle, and myocardial infarction, and those with an anterior wall or circumferential calcification in the femoral artery which would hinder performance of the approach by PCD, as assessed by Doppler ultrasound (DUS) and computed tomography (CT) angiography were excluded. Of the patients, 67 were operated with the Prostar® XL 10F PCD and 44 underwent CS.

The study protocol was approved by the Clinical Research Ethics Committee of Sifa University, Faculty of Medicine No: 311-82). The study was conducted in accordance with the principles of the Declaration of Helsinki.

All procedures were performed under general anesthesia. The aortic valve region and the annulus diameter were measured by CT angiography, which allowed the determination of the valve size to be implanted. The common femoral artery and iliofemoral artery diameters were measured in millimeter from the inner wall to the inner wall by CT angiography.

In patients who were scheduled for TAVI through the femoral route, the degree of arterial wall calcification was measured by DUS and defined as a percentage of the total wall circumference. All patients were divided into three categories: Grade 1 (non or less than 25%), grade 2 (25 to 50% without an anterior wall), and grade 3 (more than 50% without an anterior wall). The patients with more than 25% anterior wall or circumferential femoral artery calcifications in the CS group were excluded from the study.

Following a skin incision, the patients were prepared for surgery, the cutaneous and subcutaneous tissues were divided to leave lymphatic structures medially, and the main, surface, and deep femoral arteries were identified. Intravenous 100 IU/kg heparin was given. The activated clotting time (ACT) was kept at 200 to 250 sec. Arteriotomy was performed on the main femoral artery and the catheters needed for the TAVI procedure were positioned. Meanwhile, snare was applied with a 5 mm tape to prevent bleeding from the proximal end of the femoral artery. The distal femoral artery and the deep femoral artery were closed with cross-clamps. At the end of the procedure, the clamps were removed and arteriotomy was closed with 5/0 prolene sutures. A Penrose drain was inserted. At the end of the procedure, heparin was neutralized with protamine.

For the Prostar® procedure, arterial access was achieved with an 18-gauge needle by ultrasound guiding, and, then, an 8 F sheath implantation was performed. A guide wire was implanted and the 8F sheath was replaced with a 10 F Prostar® sheath. After ensuring that the needles holding the threads were located in the artery walls, the threads were stabilized, until the end of the procedure. Subsequently, 18-22 F sheaths were implanted on the guide wire for the TAVI procedure. At the end of the TAVI procedure, the ends of the threads were knotted consistent with the technique.[5] At the end of the procedure, local pressure was applied, until heparin was neutralized by the protamine. In all patients, an Edwards Sapien XT balloon-expandable valve was implanted. Technical success was defined as the completion of procedure, irrespective of the technique used (i.e., CS or PCD) without periprocedural complications and achievement of hemostasis.

Technical failure necessitating percutaneous re-intervention or open surgery and vascular injury or bleeding while still in the operation room were defined as the periprocedural complications. Complications including bleeding, hematomas, pseudoaneurysms, infections, or lymphorrhea after the procedure were completed and the patient was taken to the intensive care unit referred to the postprocedural complications.

Vascular complications were evaluated according to the classification of the Valve Academic Research Consortium (VARC)-2.[11] The VARC is a guideline to score the risk in the selection of patients for TAVI. According to the guideline, any vascular or interventional complication necessitating unplanned endovascular stent or surgical intervention (i.e., dissection, stenosis, perforation, rupture, arteriovenous fistula, pseudoaneurysm, hematoma, or percutaneous closure device failure) is defined as a vascular complication. In this regard, vascular complications in our study which were life-threatening or could cause disability or the loss of an extremity were classified as the major vascular complications, while, those which were not life-threatening were classified as the minor vascular complications.

Furthermore, bleeding-related complications were evaluated according to the classifications in the VARC-2 guideline as major and minor bleeding.[11] In general, bleeding requiring surgical intervention or which causes a fall in the hemoglobin level of at least 3.0 g/dL, or which necessitates the transfusion of two or more units is defined as major bleeding. On the other hand, bleeding which is not clinically severe at the intervention site, which does not threaten life, and which can be managed by local pressure and bandaging is defined as minor bleeding.[11]

All complications at the femoral artery intervention site 30 days postoperatively were recorded. The wound infections were erythema or an increased heat at the intervention site and exudative flow.

With daily systemic examination, the femoral intervention site and abdomen were examined and the intervention site was monitored for lymphatic leakage. In case of more than two days, lymphorrhea with complications was considered. Hematocrit level monitoring was performed on a daily basis. Before discharge from hospital, DUS was performed at the intervention site to check for possible pseudoaneurysms or arterial flow problems. The surgical procedure was performed by experienced cardiovascular surgeons, whereas the PCD procedure was carried out by experienced invasive cardiologists.

Preoperatively, all patients were given intravenous 1 g sulbactam + 1 g cefoperazone as prophylaxis. Twenty four hours before the procedure, they were also given oral 300 mg clopidogrel and 100 mg acetylsalicylic acid.

Statistical analysis
Statistical analysis was performed using SPSS 12.0 version statistical software (SPSS Inc., Chicago, IL USA). Variables in the study were calculated for normal distribution by the Kolmogorov-Smirnov test. Normally distributed continuous variables were analyzed using t-test. Abnormally distributed continuous variables were analyzed using the Mann-Whitney U test. The Fisher’s exact test was used to compare categorical variables. A p value of <0.05 was considered statistically significant.

Results

Of the patients undergoing PCD procedure and CS, 53 patients (79.1%) and 42 patients (95.5%) achieved technical success without re-intervention.

Four of the patients included in the study died on postoperative day 22±6 from pneumonia, sepsis, or severe COPD.

Baseline demographic and clinical characteristics of the patients including age, gender, and cardiac parameters, risk factors (STS and EuroSCORE II), femoral artery calcification levels, and the sizes of sheath used were similar in both patient groups (Table 1).

Table 1: Demographic parameters and risk factors of the patients

However, four PCD patients experienced technical problems with the devices. In two of these, one of the two sutures integrated into the PCD broke off, while pulling out of the device. In one of these patients, hemostasis was achieved with a single suture, while urgent surgical intervention was needed due to bleeding in the other patient. In the remaining two patients, one of the four needles on the PCD became bent, and it was difficult to retrieve it from the tunnel. Nevertheless, it was possible to tie knots, and no complications developed.

Table 2 reveals that in the stepwise backward multi regression analyses of all patients with complications (without distinguishing groups), the use of a vascular closure device, grade 3 femoral artery calcification, and an increase in sheath size were predictive variables for the development of ilio-femoral vascular complications. However, there were no any significant differences between PCD and CST groups in terms of complications and the femoral artery diameters, calcification levels and sheath sizes.

Table 2: Multivariate Hazard ratios for periprocedural vascular complications of all patients (n=111)

Periprocedural complications
In the PCD group, major vascular complications occurred in three patients (4.5%) and minor vascular complications in 19 patients (28.4%). Major complications included intimal dissection + intimal flap in one case (in the external iliac artery) and bleeding in two cases. The case of intimal dissection was treated performing percutaneous balloon angioplasty by the contralateral femoral entry, while the other two cases of bleeding (3%) underwent urgent open surgical repair (Figure 1).

Figure 1: The diagram of percutaneous vascular closure device application results.
PCD: Percutaneous vascular closure device.

Eight of 19 patients who developed minor vascular complications had local small intimal dissections in the access point; however, no intervention was needed. In the other 11 patients (16.4%), intimal dissection occurred in the access point (n=8) and external iliac artery (n=3), treated by percutaneous balloon angioplasty. In seven of these, graft-stent implantation was additionally performed.

For major and minor complications in the PCD group, percutaneous angioplasty was performed on 12 patients (17.9%), urgent surgical intervention on two (3%), and graft-stent implantation on seven (10.4%) patients (Table 3, Figure 1).

In the CS group, no major vascular complications were seen, while minor vascular complications developed in five patients (11.4%). These were intimal dissections in the common femoral artery (n=2) and external iliac artery (n=3), as the sheath induced damage to the arterial wall. The dissections diagnosed using contralateral angiography. In three of these patients, no intervention was performed, as the intimal dissection was minimal. However, in two patients with external iliac arteries (4.6%), percutaneous balloon angioplasty was performed.

Table 3: Comparision of peri- and postprocedural complications of conventional surgical technique and percutaneous closure devices groups

As a result, a significantly higher number of PCD patients experienced total vascular complications (p=0.012) and needed secondary vascular interventions (p=0.043) [emergency surgical intervention (3%), percutaneous balloon angioplasty (17.9%), and graftstent implantation (10.4%)], compared to the CS group (Table 3).

On the other hand, there was no significant difference in the femoral artery diameters, calcification levels, and sheath sizes between the PCD and CS patients. In addition, none of the patients had embolism or thrombosis.

Postprocedural complications
In the PCD patients, postprocedural wound complications developed in seven patients (10.4%). This was in the form of femoral access site infection in three patients, lymphorrhea in three patients, and a late pseudoaneurysm in one patient. Two patients who developed infection were those who underwent urgent surgical repair for major vascular complications. The other patient underwent graft-stent implantation for minor vascular complications. One of the three patients who developed lymphorrhea and the patient who developed a pseudoaneurysm were later re-hospitalized for surgery (Figure 1).

In the CS patients, wound complications developed in 15 patients (34.1%). These included femoral access site infection in seven patients, and lymphorrhea in eight patients. Four of these patients who developed wound complications were re-hospitalized for lymphocele, and two for the wound site infection (Figure 2).

Figure 2: The diagram of conventional surgery results.

There was also a significant difference in the postprocedural complications (p=0.04) and length of hospital stay (p=0.04) between the PCD and CS patients. The mean length of hospital stay was 4.7±1.2 days for the CS group and 4.2±1.6 days for the PCD group (p=0.048). The re-hospitalization rate relating to the wound complications at the access site was 3% (n=2) in the PCD group and 13.6% (n=6) in the CS group (Table 3).

In addition, the rate of loss of hemoglobin compared to baseline was measured as 0.9±0.4 mg/dL in the CS group and 1.1±0.4 mg/dL in the PCD group.

Discussion

Our study results showed that CS was more effective than PCD with lower periprocedural complications and vascular re-interventions. In addition, the rate of percutaneous angioplasty and the use of graft-stent for major and minor complications in PCD patients were significantly higher than for CS patients. However, the postprocedural wound complications were significantly fewer in the PCD group than CS group.

Using a catheter smaller than 8 F, bleeding can generally be stopped by primary pressure. In spite of this, many vascular closure devices have been developed to reduce possible complications.[12] However, depending on the type of device to be implanted, the diameter of catheters and sheaths used for endovascular aneurysm repair (EVAR) thoracic endovascular aneurysm repair (TEVAR), and TAVI procedures particularly makes it virtually impossible to control bleeding by primary compression.[13] Currently, PCDs developed to close the holes of large-diameter sheaths (>10 F) promise the possibility of less invasive intervention than surgical preparation.[1,6,14-16] They also offer the advantages of shorter operation time, earlier patient mobilization, and earlier discharge.[7]

The success rate with PCDs ranges between 71.4 and 96%.[5,14-19] It corresponds to a failure rate for PCDs of between 4 and 28%. In a multicenter study, major vascular complications or in-hospital mortality rate were reported to be 9.5% with Prostar.[20]

On the other hand, the main reasons for failure are obesity, calcific femoral arteries, and tortuosity in iliac arteries.[2,7,8,21,22] The main complications include bleeding, dissection, thrombosis and lack of technical success.[1,6,8,10,16] In our study, technical success rate were 79.1% for PCD group and 95.5% for CS group.

Several meta-analyses reported that complication rates for PCD were similar to those for CS.[7,12] In our study, the rate of major and minor complications seen in the PCD group was significantly higher than CS group. For the treatment of these complications, percutaneous angioplasty was performed on 12 patients (17.9%), emergency surgical intervention on two patients (3%), and graft-stent implantation on seven patients (10.4%) (Table 3).

Furthermore, the rate of femoral artery complications and conversion to open surgery due to the technical failure in PCD was reported to be higher in calcific arteries.[21,22] In addition, the need for urgent open surgery can still arise, due to technical problems relating to PCD or uncontrolled bleeding. In their study, Teh et al.[6] reported this rate as 13.4%. In the present study, the patients with severe femoral artery calcifications who were referred to CS were excluded from the study. According to our results, the rate of urgent open surgery was %3 in PCD group. In particular, patients who underwent urgent surgery due to unsuccessful PCD suffered more postprocedural wound-related complications, such as infection and lymphorrhea than elective CS patients (Figure 1).

In a systematic study, the use of PCD in EVAR procedures caused less access site problems than open surgical repair.[2] The complication rate was higher in obese patients, particularly. Similarly, the rates of femoral access site wound infection and lymphorrhea were significantly higher in CS patients than in PCD patients in our study. However, no predictor was able to be identified to show the difference between the groups.

In the literature, there are few comprehensive studies comparing PCD and CS in terms of length of hospital stay. Although these studies usually found no difference between the patient groups, some authors reported that the length of hospital stay was shorter among the PCD patients.[7] Consistent with these findings, the length of hospital stay was significantly longer for CS group, compared to PCD group (p=0.048) due to wound site complications. The main reasons relating to the wound site complications for prolonged hospital stay and re-hospitalization were lymphorrhea and wound site infection.

In the present study, although the re-hospitalization rates relating to access complications were similar in both groups, the rate in the CS group was higher than PCD group. The main causes for wound-related re-hospitalization were lymphorrhea, lymphocele, and wound site infections.

In addition, both groups were similar in terms of bleeding and blood transfusion rates. The main reason for loss of blood was leakage from around the guide wire, as it moved forward from inside the sheath. There was a need for blood transfusion in both groups (CS 31%, PCD 24%), due to the loss of blood. Although it was similar between the groups, this is a considerably high rate. It can be attributed to the length of the procedure. In our first TAVI patients, the longer the procedure took, the greater the amount of bleeding from around the guide wire inside the sheath. However, as the team gained technical experience and the procedure was completed in a shorter time, further cases had less need for blood transfusions.

From the point of view of periprocedural and postprocedural complications, there were statistically significant differences between PCD and CS groups. In PCD group, the rates of total vascular complications, percutaneous angioplasty, and graft-stent implantation were significantly higher. In addition, major vascular complications were slightly more in PCD group. In contrast, the rate of postprocedural complications was significantly higher in the CS group. Although the rates of re-hospitalization due to the wound site complications were similar, they were found to be higher in the CS group.

We used Single Prostar® device for PCD in our center. However, Saleh et al.[23] reported that double Prostar® is more effective than single device with higher technical success and lower vascular complications. On the other hand, although we do not have an experience on double Prostar®, we believe that more sophisticated devices can yield improved results.

Nonetheless, there are some limitations to this study. First, this is a retrospective single-center experience with a limited number of patients.

Second, due to only one type of percutaneous device (Prostar®) used, the results cannot be generalized to all patient populations and percutaneous catheter trademarks. In addition, femoral calcification levels were classified by bedside DUS, but not by CT angiography. Finally, the access site complications such as lymphorrhea and infection were evaluated by clinical examinations, but not using laboratory studies. Therefore, no attempt was made to quantify the infection.

In conclusion, our study results suggest that, although percutaneous closure devices have the advantages of being less invasive procedures with a shorter hospital stay, conventional surgery is a more effective and safer method for femoral artery access site closure during transcatheter aortic valve implantation with a lower rate of periprocedural complications and re-interventions.

Declaration of conflicting interests
The authors declared no conflicts of interest with respect to the authorship and/or publication of this article.

Funding
The authors received no financial support for the research and/or authorship of this article.

References

1) Torsello GB, Kasprzak B, Klenk E, Tessarek J, Osada N, Torsello GF. Endovascular suture versus cutdown for endovascular aneurysm repair: a prospective randomized pilot study. J Vasc Surg 2003;38:78-82.

2) Malkawi AH, Hinchliffe RJ, Holt PJ, Loftus IM, Thompson MM. Percutaneous access for endovascular aneurysm repair: a systematic review. Eur J Vasc Endovasc Surg 2010;39:676-82.

3) Bechara CF, Barshes NR, Pisimisis G, Chen H, Pak T, Lin PH, et al. Predicting the learning curve and failures of total percutaneous endovascular aortic aneurysm repair. J Vasc Surg 2013;57:72-6.

4) Jean-Baptiste E, Hassen-Khodja R, Haudebourg P, Bouillanne PJ, Declemy S, Batt M. Percutaneous closure devices for endovascular repair of infrarenal abdominal aortic aneurysms: a prospective, non-randomized comparative study. Eur J Vasc Endovasc Surg 2008;35:422-8.

5) Haas PC, Krajcer Z, Diethrich EB. Closure of large percutaneous access sites using the Prostar XL Percutaneous Vascular Surgery device. J Endovasc Surg 1999;6:168-70.

6) Teh LG, Sieunarine K, van Schie G, Goodman MA, Lawrence- Brown M, Prendergast FJ, et al. Use of the percutaneous vascular surgery device for closure of femoral access sites during endovascular aneurysm repair: lessons from our experience. Eur J Vasc Endovasc Surg 2001;22:418-23.

7) Haulon S, Hassen Khodja R, Proudfoot CW, Samuels E. A systematic literature review of the efficacy and safety of the Prostar XL device for the closure of large femoral arterial access sites in patients undergoing percutaneous endovascular aortic procedures. Eur J Vasc Endovasc Surg 2011;41:201-13.

8) Nehler MR, Lawrence WA, Whitehill TA, Charette SD, Jones DN, Krupski WC. Iatrogenic vascular injuries from percutaneous vascular suturing devices. J Vasc Surg 2001;33:943-7.

9) Hazan E, Şişli E, Göktay Y, Sarıosmanoğlu ON, Oto Ö. Posterior Wall Capture with the Application of Prostar XL® vascular closure device: case report. Turkiye Klinikleri J Cardiovasc Sci 2012;24:353-6.

10) Yüksel İÖ, Köklü E, Arslan Ş, Cağırcı G, Küçükseymen S. A case of transcatheter aortic valve implantation complication with total femoral artery thrombosis due to failure of the ProStar device. Turk Kardiyol Dern Ars 2015;43:651-4.

11) Kappetein AP, Head SJ, Généreux P, Piazza N, van Mieghem NM, Blackstone EH, et al. Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document. J Thorac Cardiovasc Surg 2013;145:6-23.

12) Koreny M, Riedmüller E, Nikfardjam M, Siostrzonek P, Müllner M. Arterial puncture closing devices compared with standard manual compression after cardiac catheterization: systematic review and meta-analysis. JAMA 2004;291:350-7.

13) Rijkée MP, Statius van Eps RG, Wever JJ, van Overhagen H, van Dijk LC, Knippenberg B. Predictors of Failure of Closure in Percutaneous EVAR Using the Prostar XL Percutaneous Vascular Surgery Device. Eur J Vasc Endovasc Surg 2015;49:45-9.

14) Howell M, Villareal R, Krajcer Z. Percutaneous access and closure of femoral artery access sites associated with endoluminal repair of abdominal aortic aneurysms. J Endovasc Ther 2001;8:68-74.

15) Kurşaklioğlu H, Iyisoy A, Barçin C, Celik T, Nitzan R, Köse S, et al. The experience with the Epiclose-T vascular access closure device: a human study. Anadolu Kardiyol Derg 2008;8:38-42.

16) Traul DK, Clair DG, Gray B, O’Hara PJ, Ouriel K. Percutaneous endovascular repair of infrarenal abdominal aortic aneurysms: a feasibility study. J Vasc Surg 2000;32:770-6.

17) Howell M, Doughtery K, Strickman N, Krajcer Z. Percutaneous repair of abdominal aortic aneurysms using the AneuRx stent graft and the percutaneous vascular surgery device. Catheter Cardiovasc Interv 2002;55:281-7.

18) Hayashida K, Lefèvre T, Chevalier B, Hovasse T, Romano M, Garot P, et al. True percutaneous approach for transfemoral aortic valve implantation using the Prostar XL device: impact of learning curve on vascular complications.JACC Cardiovasc Interv 2012;5:207-14.

19) Barbier CE, Lundin E, Melki V, James S, Nyman R. Percutaneous Closure in Transfemoral Aortic Valve Implantation: A Single-Centre Experience. Cardiovasc Intervent Radiol 2015;38:1438-43.

20) Barbash IM, Barbanti M, Webb J, Molina-Martin De Nicolas J, Abramowitz Y, Latib A, et al. Comparison of vascular closure devices for access site closure after transfemoral aortic valve implantation. Eur Heart J 2015;36:3370-9.

21) Mousa AY, Campbell JE, Broce M, Abu-Halimah S, Stone PA, Hass SM, et al. Predictors of percutaneous access failure requiring open femoral surgical conversion during endovascular aortic aneurysm repair. J Vasc Surg 2013;58:1213-9.

22) Reinthaler M, Aggarwal SK, De Palma R, Landmesser U, Froehlich G, Yap J, et al. Predictors of clinical outcome in transfemoral TAVI: circumferential iliofemoral calcifications and manufacturer-derived recommendations. Anatol J Cardiol 2015;15:297-305.

23) Saleh N, De Palma R, Settergren M, Rück A. Femoral accessrelated complications during percutaneous transcatheter aortic valve implantation comparing single versus double Prostar XL device closure. Catheter Cardiovasc Interv 2015;86:1255-61.

Keywords : Endovasküler girişim; perkütan kapatma; transkateter aort kapak implantasyonu, vasküler komplikasyon
Viewed : 7307