Herein, we present a 53-day-old male infant with a gestational age of 28 weeks with a birth weight of 670 grams who was born by C-section delivery. A 28-gauge polyurethane (PremiCath) central venous catheter was inserted into his right arm on Day 47 due to nosocomial sepsis and necrotizing enterocolitis. At the sixth day of the treatment, his overall condition deteriorated abruptly. His blood pressure decreased and he did not respond inotropic agents and volume load. The infant had tachypnea, tachycardia, and an increased need for oxygen and ventilation support. Plain radiography showed that the shadow of the heart was wide and the tip of the catheter was in the right ventricle (Figure 1). Following confirmation of the suspicion of PCE with cardiac tamponade by echocardiography, percutaneous subxiphoid pericardiocentesis was immediately performed using a 22-gauge needle and 51 mL fluid, which was compatible with total parenteral nutrition solution, was drained (Figure 2a). The catheter was removed and the oxygen and inotropic requirement, then, decreased significantly. Echocardiography performed on the following day demonstrated no PCE, but a thrombus formation in the right ventricle. After pericardiocentesis and removing the catheter, PCE and cardiac tamponade did not recur. Thrombus formation (4.11x2.71 mm) in the right ventricle (Figure 2b) was treated with low-molecular weight heparin (1.5 mg/kg/day) for two weeks and the right ventricular thrombus resolved. The infant was discharged from the hospital without any sequelae associated with this complication.
Figure 1: The tip of the line was in the right ventricle and the shadow of the heart was wide.
Catheter associated PCE and cardiac tamponade is seen 1 to 3% of neonates.[7,8] About 30 to 50% result in death.[6] The only preventive attempt is to insert the line exact position. However, we should check the position on a regular basis, as it may move on over time. The common incorrect position of the tip of the catheter is the right atrium and the thrombus is usually formed in this location.[9] Interestingly, in our case, the tip of the catheter and the thrombus formation was in the right ventricle.
The aim of this case report is to emphasize that if sudden cardiovascular collapse occurs in an infant with a peripherally inserted central venous catheter, the possibility of catheter complications, particularly cardiac tamponade, should be primarily considered. Our experience shows that early diagnosis of cardiac tamponade and timely pericardiocentesis can be lifesaving in most of the cases.
Declaration of conflicting interests
The authors declared no conflicts of interest with respect to
the authorship and/or publication of this article.
Funding
The authors received no financial support for the research
and/or authorship of this article.
1) Pizzuti A, Parodi E, Abbondi P, Frigerio M. Cardiac
tamponade and successful pericardiocentesis in an extremely
low birth weight neonate with percutaneously inserted
central venous line: a case report. Cases J 2010;3:15.
2) Pettit J. Assessment of infants with peripherally inserted
central catheters: Part 2. Detecting less frequently occurring
complications. Adv Neonatal Care 2003;3:14-26.
3) Ohki Y, Maruyama K, Harigaya A, Kohno M, Arakawa
H. Complications of peripherally inserted central venous
catheter in Japanese neonatal intensive care units. Pediatr Int
2013;55:185-9.
4) Tekelioğlu ÜY, Gürses EL, Saçar M, Sungurtekin H.
Malpositions of central venous catheter: three case reports.
Turk Gogus Kalp Dama 2011;19:276-8.
5) Warren M, Thompson KS, Popek EJ, Vogel H, Hicks J.
Pericardial effusion and cardiac tamponade in neonates:
sudden unexpected death associated with total parenteral
nutrition via central venous catheterization. Ann Clin Lab
Sci 2013;43:163-71.
6) Haass C, Sorrentino E, Tempera A, Consigli C, De Paola D,
Calcagni G, et al. Cardiac tamponade and bilateral pleural
effusion in a very low birth weight infant. J Matern Fetal
Neonatal Med 2009;22:137-9.
7) Ohki Y, Maruyama K, Harigaya A, Kohno M, Arakawa
H. Complications of peripherally inserted central venous
catheter in Japanese neonatal intensive care units. Pediatr Int
2013;55:185-9.