Methods: The study included 41 patients (29 males, 12 females; mean age 51.9±10.4 years; range, 30 to 77 years) who underwent total thoracic aorta repair with frozen elephant trunk stent graft for acute type A aortic dissection between November 2013 and November 2017. The reduction in false lumen size and thrombosis were evaluated by repeated computed tomographyangiography on 10th day and third, sixth, and 12th months.
Results: Six patients (14.6%) were lost during hospital stay and one patient (2.4%) was lost during the follow-up period. Frozen elephant trunk stent graft"s distal end at descending aorta ended at T6, T7, and T8 levels in 15 (36.6%), 21 (51.2%), and five (12.2%) patients, respectively. The supra-aortic vessels were re-implanted separately in 21 (51.2%) or as island in 20 (48.8%) patients. Transient paraparesis (spinal cord ischemia) was observed in only one patient (2.4%), while permanent neurologic deficit (stroke or coma) was observed in two patients (4.9%). Mean duration of follow-up was 26.5±20.5 months. Computed tomography-angiography at first month showed that false lumen became thrombosed at rates of 93.9% and 54.5% at pulmonary trunk and diaphragmatic level, respectively.
Conclusion: We believe that total arcus repair in acute type A aortic dissection treatment with single-session frozen elephant trunk technique by ensuring early false lumen thrombosis is safe and successful.
Table 1: Patients" demographic characteristics
All patients were diagnosed by computed tomography (CT) angiography and examined for cardiac function and valve pathologies with echocardiography. In all patients, the primary rupture started from ascending aorta while additional secondary rupture was observed in 13 patients (31.7%). Radiological and anatomic characteristics of the dissection were presented in Table 2.
Table 2: Radiological and anatomic features of aortic dissections
Six patients (14.6%) developed renal malperfusioncaused acute renal dysfunction. Mesenteric ischemia or visceral malperfusion was not observed in any patient. Two patients (4.9%) applied for paraplegia caused by spinal cord ischemia. One patient (2.4%) developed right hemiplegia due to occlusion of left carotid artery by dissection flap. But his neurologic deficit recovered during the transfer from neurology clinic to our hospital.
In one patient, ATAAD was detected via CT angiography performed due to the suspicion of dissection flap in echocardiography which was performed because of deterioration of medical status on second postoperative day after mitral valve replacement and tricuspid De Vega procedure. The patient underwent an urgent operation after resuscitation.
The reduction in false lumen size and thrombosis were evaluated by repeating the CT angiography on 10th day and third, sixth, and 12th months. Evaluation was performed using lumen and pseudo-lumen diameters and measurements performed at two different levels of descending aorta. Levels were determined as descending aorta at pulmonary bifurcation level[1] and the descending aorta at diaphragmatic level.[2] Thrombosis evaluation was classified in accordance with false lumen contrasting. False lumen reduction was assessed by comparison with preoperative CT angiography.
Patients underwent operation within the first 14 days from the start of back pain and other symptoms of acute dissection. Early mortality was defined as mortality within the first 30 days. Contrast thoraco-abdominal CT was utilized in diagnosis and follow-up of aortic pathologies. Acute renal dysfunction was defined as the increase in serum creatinine level higher than 1.8 mg/dL without known previous renal dysfunction. Cerebral vascular disease definition was defined as having a cerebrovascular event before 72 hours. Patients considered as suspicious by intensive care unit team for neurological deficit during physical examination were consulted by a neurologist.
In our study, the E-vita OPEN PLUS prostheses were used in all patients. Central catheter, arterial monitorization via left arm, cerebral pulse oximeter, and cerebrospinal fluid pressure catheter were used routinely in all patients. Arcus repair was performed in moderate hypothermia using unilateral selective anterograde cerebral perfusion (flow rate=10-15 mL/kg/min). However, when significant decrease in saturation was detected via cerebral pulse oximeter, bilateral anterograde selective cerebral perfusion was performed.
Median sternotomy was applied to all patients. While right subclavian artery was used for arterial cannulation, venous drainage was provided by using right atrium. Vent cannula was placed from upper-right pulmonary vein. Myocardial protection was ensured with blood cardioplegia. Proximal aorta repair was performed in cooling phase. When nasopharyngeal temperature was 26°C, aortic clamp was removed, and selective anterograde cerebral perfusion was started. E-vita OPEN PLUS prosthesis was fixed to aorta wall via single U sutures at 1 cm distal of left subclavian artery. The stent graft size was calculated by considering the real lumen diameter of aorta measured in tomography preoperatively. When the arcus elements were anastomosed with separate grafts, proximal suture line of FET graft was shifted to between left carotid artery and left subclavian artery and a fourth branch was added to provide distal perfusion. In all patients, FET prosthesis placement into the true lumen was confirmed with the guidance of trans-esophageal echocardiography. Then, the E-vita OPEN PLUS prosthesis was anastomosed to pre-implanted proximal Dacron graft. Because no dissection was detected in arcus components in isletshape arcus aorta replacement cases, arcus aorta was repaired by resecting only the small curvature of arcus aorta and protecting the unity of descending aorta and islet including the components of aortic arch as we described previously.[9]
Statistical analysis
The IBM SPSS version 22.0 (IBM Corp., Armonk,
NY, USA) software was used in statistical analyses. In analyzing the study data, besides the definitive
statistical methods (mean, standard deviation, and
frequency), paired sample t-test was utilized in
preoperative-postoperative comparison of quantitative
data. A p value <0.05 was considered as statistically
significant.
Table 3: Intraoperative values
Hospital mortality rate was 17.1% (n=6). The causes of death were aortic complications (n=3), multiple organ failure (n=1), stroke (n=1), and low cardiac output syndrome (n=1). One patient had Marfan syndrome and died on second postoperative day due to bleeding diathesis.
Second patient who had Marfan syndrome applied to our clinic with complaint of difficulty in breathing one month postoperatively. No aortic pathology could be detected in the patient, but he was intubated due to pulmonary regurgitation, and died in 66th postoperative day due to multiple organ failure. Third patient was 76 years old and applied to another center with complaint of dyspnea. No aortic complication was detected in controls and he was diagnosed with pneumonia, but died due to pulmonary failure.
Frozen elephant trunk stent graft"s distal end at descending aorta ended at T6, T7, and T8 levels in 15 (36.6%), 21 (51.2%), and five (12.2%) patients, respectively. While paraparesis (spinal cord ischemia) was observed in only one patient (2.4%), permanent neurologic deficit (stroke or coma) was observed in two patients (4.9%). The patient having paraparesis had no neurologic deficit when discharged. Other postoperative complications were presented in Table 4.
Data of 24 patients were compiled for followup until January 2018 and only one patient died during follow-up. Mean duration of follow-up was 26.5±20.5 months. Besides the decrease in aorta diameters, false lumen was thrombosed in short-term. Postoperative CT findings were presented in Table 5.
Table 5: Computed tomography-angiography findings at follow-up (n=33)
Pre- and postoperative aortic diameters were compared with t-test in dependent groups. There was a statistically significant difference between pre- (37.4±8.9) and postoperative (31.8±4.9, p<0.001) aortic diameters. The mean difference between the two groups was 5.60 mm (95% confidence interval [8.10-3.09]) (Figure 1).
Figure 1: Comparison of pre- and postoperative aortic diameters.
The first 30-day mortality rate of conventional type A aortic dissection surgery has been reported to be between 9% and 21%.[13,14] In a systematic examination and meta-analysis of Tian et al.[17] on FET-implemented patients, the first 30-day mortality in ATAAD has been reported to be 7.7% (0-18.2%). The mortality rates represented in our study are compatible with the literature.
While Uchida et al.[18] reported 2.5% for stroke, 3.8% for transient renal failure, 7.5% for lung failure, and 5% for bleeding revision in postoperative follow-up, Roselli et al.[19] reported the stroke rate as 12%, lung failure as 12%, and renal failure as 19%. Both teams have reported the percentage of paraplegia as 0%. In our study, the percentage of stroke was observed to be 6.9%, pulmonary complications 7%, and newly developed renal failure 14.6%, while no paraplegia was observed.
The most feared complication that can develop even though measures are taken for FET is the newly developed neurologic deficit.[20] In a multi-center study of Tsakagis et al.,[21] the percentage of stroke development has been reported to be 10%, while the percentage of paraparesis has been observed to be 1%. Moreover, in a meta-analysis of their study of FET implementation in ATAAD, Tian et al.[17] have reported stroke between 0% and 11.8% and spinal cord damage between 0% and 8.3%. Even if advanced age is considered to be a risk factor for stroke,[22] aortic dissection involving acute pathology forms an operation-independent risk factor. However, the stent graft ends below T8 and the occlusion of the intercostal arteries due to the closure of the left subclavian artery by the graft are accepted to be particular predisposing risk factors for spinal cord damage. Our study produced similar results with the literature.
Supra-coronary graft replacement is a simple and classical treatment method of ATAAD. Residual dissection due to patent false lumen may develop complications that consequently necessitate reoperation in long-term and increase mortality. The reoperation risk of aorta in distal residual dissection segment after conventional dissection surgery is at a remarkable level of 30%.[6-8] There are three important factors here: segmented diameters of aorta, non-thrombosed false lumen, and uncontrollable hypertension.[23] With FET technique, false lumen decreases and becomes totally thrombosed at the level of graft even in shortterm. In segment at distal of the graft, false lumen has been determined to be highly thrombosed.[24-25] In our study, C T angiography performed in the follow-up showed that false lumen became fully thrombosed at rates of 93.9% and 54.5% at pulmonary trunk and diaphragmatic level, respectively.
The limited number of retrospective data and cases limits our study; however, the study could represent the advantages and success of single-phase distal aorta treatment of ATAAD in mid-term. Longterm follow-up is required to compare the results of FET technique with residual-dissection-caused complications observed in long-term.
In conclusion, to prevent complications such as rupture and malperfusion that can develop due to false lumen gap, we believe that performing total arcus repair in acute type A aortic dissection treatment with single-session frozen elephant trunk technique by ensuring early false lumen thrombosis is safe and successful.
Declaration of conflicting interests
The authors declared no conflicts of interest with respect to
the authorship and/or publication of this article.
Funding
The authors received no financial support for the research
and/or authorship of this article.
EDITORIAL COMMENT
Anıl Z. Apaydın
Type A acute aortic dissection (TAAAD) is the
most c atastrophic d isease o f t he a orta. P atients
with TAAAD may present with a wide variety of
symptoms and the clinical picture may vary from a
very stable one to a state of shock due to tamponade
or severe malperfusion. The primary goal of the
operation for this lethal disease is the survival of the patient. There are number of surgical alternatives
ranging from a simple ascending aortic replacement
to valve preserving root replacement and total arch
replacement. The secondary goal is to provide the
surviving patient with a life eliminating future risks
of possible distal aortic rupture or intervention/
operation.
According to the authors of this article, total arch replacement with frozen elephant trunk (FET) is a procedure which can achieve the aforementioned goals.[1] However, I have concerns about the efficacy and the safety of this operation.
The idea of elephant trunk operation emerged as a two-stage solution in patients with mega-aortic pathologies to facilitate the second stage. It received criticism due to high combined mortality of the two stages and the interval between them. With the introduction of endovascular techniques, the second stage could have been completed by a thoracic endovascular aortic repair (TEVAR) procedure. The technique of FET with the use of hybrid grafts facilitated the second stage even further by providing a convenient landing zone. The FET has been used in TAAAD to obliterate the false lumen in the descending aorta with the expectation that it would prevent the dilatation of the distal aorta in long-term and it would relieve the malperfusion in short-term.
In their retrospective analysis of 41 patients with TAAAD who underwent total arch replacement with FET, the authors reported that the false lumen of the descending aorta became thrombosed, particularly at the proximal part.[1] The authors a lso r eported t hat this technique decreased the size of the descending aortic diameter, compared to the preoperative values. The overall mortality and morbidity rates in this series compare favorably with those in previous similar reports. However, the rate of malperfusion (particularly the visceral malperfusion which was not seen in the series) is less than the usual reports regarding acute dissection. It is well-known that malperfusion syndrome which is seen in about 30% of the TAAAD significantly increases the operative mortality.[2] The difference between the pre- and postoperative diameters of the descending aorta could be explained by the pressure drop in the false channel by the closure/ exclusion of the intimal tear during the proximal repair, not because of the implementation of FET. The rate of temporary neurological dysfunction (i.e., lethargy and agitation) and left diaphragm paralysis due to a trauma to the recurrent laryngeal nerve should have been also mentioned, since they are common complications of prolonged brain protection and total arch replacement, respectively.
The FET is a technically difficult operation, particularly in patients with TAAAD considering the inherited risks of this disease such as friable aorta, coagulation problems, and metabolic changes due to malperfusion. The reported bleeding and tamponade rate in this series seems to be slightly high. It may not be easy to place a stented graft into a dissected descending aorta in every patient and stent-induced new entry is another potential problem.
This technique can not overcome the impact of distal reentries below the bottom of the FET which can cause the dilatation of those segments. The rate of distal reinterventions was significant in a report of 94 TAAAD patients who underwent FET.[3] In a report by Zierer,[4] i n which t he follow-up was 100% c omplete, only 15 distal aortic reoperations were required in 168 operative survivors of TAAAD within a mean period of 60±50 months postoperatively. Therefore, every patient does not need a prophylaxis. The factors which influence the natural history of the residual aorta still remain incompletely understood and the effect of the patent false lumen on the prognosis is debatable.
To expose an acutely ill patient to a longer period of brain and lower body ischemia for a prophylactic application of FET should be only justified by a very solid evidence. To the best of my knowledge, it is not available yet. Currently, this approach should be used in clinically stable patients with a tear or rentry tear in the distal aortic arch or proximal descending aorta.
Despite all the criticism I have made for this technique, I do appreciate the current work and also, the ongoing efforts of this group for pioneering FET technique in Turkey in an attempt to provide dissection patients with an improved quality of life without secondary interventions.
REFERENCES
1. Akbulut M, Ak A, Arslan Ö, Çekmecelioğlu D, Taş S, Antal
Dönmez A, et al. Early and mid-term results of frozen
elephant trunk procedure for acute type A aortic dissection.
Turk Gogus Kalp Dama 2019;27:135-42.
2. Apaydın AZ, Büket S, Posacıoğlu H, İslamoğlu F, Çalkavur T, Yağdı T, et al. Perioperative risk factors for mortality in patients with acute type A aortic dissection. Annals of Thoracic Surgery 2002;74:2034-39.
3. Shrestha M, Haverich A, Martens A. Total aortic arch replacement with the frozen elephant trunk procedure in acute DeBakey type I aortic dissections. Eur J Cardiothorac Surg 2017;51:i29-i34.
4. Zierer A, Voeller RK, Hill KE, Kouchoukos NT, Damiano Jr RJ, Moon MR, et al. Aortic Enlargement and Late Reoperation After Repair of Acute Type A Aortic Dissection. Ann Thorac Surg 2007;84:479-86.
Correspondence: Anıl Z. Apaydın, MD. Ege Üniversitesi Tıp Fakültesi
Kalp ve Damar Cerrahisi Anabilim Dalı, 35100 Bornova, İzmir, Turkey.
Tel: +90 232 - 388 10 23 e-mail: anil.apaydin@ege.edu.tr
1) Geirsson A, Bavaria JE, Swarr D, Keane MG, Woo
YJ, Szeto WY, et al. Fate of the residual distal and
proximal aorta after acute type a dissection repair using
a contemporary surgical reconstruction algorithm. Ann
Thorac Surg 2007;84:1955-64.
2) Tan ME, Morshuis WJ, Dossche KM, Kelder JC, Waanders
FG, Schepens MA. Long-term results after 27 years of
surgical treatment of acute type a aortic dissection. Ann
Thorac Surg 2005;80:523-9.
3) Danner BC, Natour E, Horst M, Dikov V, Ghosh PK, Dapunt
OE. Comparison of operative techniques in acute type A
aortic dissection performing the distal anastomosis. J Card
Surg 2007;22:105-10.
4) Özçınar E, Çakıcı M, Baran Ç, Gümüş F, Özgür A,
Yazıcıoğlu L, et al. Results of late-onset type A aortic
dissection after previous cardiac surgery: Does prior
coronary artery bypass grafting affect survival? Turk
Gogus Kalp Dama 2018;26:1-7.
5) DeBakey ME, McCollum CH, Crawford ES, Morris GC
Jr, Howell J, Noon GP, et al. Dissection and dissecting
aneurysms of the aorta: twenty-year follow-up of five
hundred twenty-seven patients treated surgically. Surgery
1982;92:1118-34.
6) Tsagakis K, Tossios P, Kamler M, Benedik J, Natour D,
Eggebrecht H, et al. The DeBakey classification exactly
reflects late outcome and re-intervention probability in acute
aortic dissection with a slightly modified type II definition.
Eur J Cardiothorac Surg 2011;40:1078-84.
7) Malvindi PG, van Putte BP, Sonker U, Heijmen RH,
Schepens MA, Morshuis WJ. Reoperation after acute type a
aortic dissection repair: a series of 104 patients. Ann Thorac
Surg 2013;95:922-7.
8) Gariboldi V, Grisoli D, Kerbaul F, Giorgi R, Riberi A,
Metras D, et al. Long-term outcomes after repaired acute
type A aortic dissections. Interact Cardiovasc Thorac Surg
2007;6:47-51.
9) Akbulut M, Arslan O, Ak A, Tas S, Cekmecelioglu D,
Donmez AA, et al. Early period results for repair of complex
thoracic aortic diseases with E-vita open stent graft. EJCM
2017;5:1-6
10) Trimarchi S, Nienaber CA, Rampoldi V, Myrmel T, Suzuki
T, Mehta RH, et al. Contemporary results of surgery in acute
type A aortic dissection: The International Registry of Acute
Aortic Dissection experience. J Thorac Cardiovasc Surg
2005;129:112-22.
11) Hiratzka LF, Bakris GL, Beckman JA, Bersin RM, Carr
VF, Casey DE Jr, et al. 2010 ACCF/AHA/AATS/ACR/ASA/
SCA/SCAI/SIR/STS/SVM guidelines for the diagnosis and
management of patients with thoracic aortic disease: executive
summary. A report of the American College of Cardiology
Foundation/American Heart Association Task Force on
Practice Guidelines, American Association for Thoracic
Surgery, American College of Radiology, American Stroke
Association, Society of Cardiovascular Anesthesiologists,
Society for Cardiovascular Angiography and Interventions,
Society of Interventional Radiology, Society of Thoracic
Surgeons, and Society for Vascular Medicine. Catheter
Cardiovasc Interv 2010;76:E43-86.
12) Westaby S, Saito S, Katsumata T. Acute type A dissection:
conservative methods provide consistently low mortality.
Ann Thorac Surg 2002;73:707-13.
13) Crawford ES, Kirklin JW, Naftel DC, Svensson LG, Coselli
JS, Safi HJ. Surgery for acute dissection of ascending aorta.
Should the arch be included? J Thorac Cardiovasc Surg
1992;104:46-59.
14) Crawford ES, Svensson LG, Coselli JS, Safi HJ, Hess KR.
Aortic dissection and dissecting aortic aneurysms. Ann Surg
1988;208:254-73.
15) David TE, Armstrong S, Ivanov J, Barnard S. Surgery
for acute type A aortic dissection. Ann Thorac Surg
1999;67:1999-2001.
16) Kirsch M, Soustelle C, Houël R, Hillion ML, Loisance D.
Risk factor analysis for proximal and distal reoperations
after surgery for acute type A aortic dissection. J Thorac
Cardiovasc Surg 2002;123:318-25.
17) Tian DH, Wan B, Di Eusanio M, Black D, Yan TD. A
systematic review and meta-analysis on the safety and
efficacy of the frozen elephant trunk technique in aortic arch
surgery. Ann Cardiothorac Surg 2013;2:581-91.
18) Uchida N, Katayama A, Tamura K, Sutoh M, Kuraoka M,
Ishihara H. Frozen elephant trunk technique and partial
remodeling for acute type A aortic dissection. Eur J
Cardiothorac Surg 2011;40:1066-71.
19) Roselli EE, Rafael A, Soltesz EG, Canale L, Lytle
BW. Simplified frozen elephant trunk repair for acute
DeBakey type I dissection. J Thorac Cardiovasc Surg
2013;145:197-201.
20) Bavaria JE, Brinster DR, Gorman RC, Woo YJ, Gleason
T, Pochettino A. Advances in the treatment of acute type
A dissection: an integrated approach. Ann Thorac Surg
2002;74:1848-52.
21) Tsagakis K, Pacini D, Di Bartolomeo R, Gorlitzer M, Weiss
G, Grabenwoger M, et al. Multicenter early experience
with extended aortic repair in acute aortic dissection: is
simultaneous descending stent grafting justified? J Thorac
Cardiovasc Surg 2010;140:116-20.
22) Rylski B, Suedkamp M, Beyersdorf F, Nitsch B, Hoffmann
I, Blettner M, et al. Outcome after surgery for acute
aortic dissection type A in patients over 70 years: data
analysis from the German Registry for Acute Aortic
Dissection Type A (GERAADA). Eur J Cardiothorac Surg
2011;40:435-40.
23) Zierer A, Voeller RK, Hill KE, Kouchoukos NT, Damiano
RJ Jr, Moon MR. Aortic enlargement and late reoperation
after repair of acute type A aortic dissection. Ann Thorac
Surg 2007;84:479-86.