Methods: We retrospectively evaluated a total of 167 patients (67 males, 100 females; mean age 56.8±6.9 years; range, 48 to 65 years) with atrial fibrillation who underwent monopolar or bipolar radiofrequency ablation concomitant to mitral valve surgery between September 2001 and January 2015. The patients were divided into two groups according to the procedure applied as those undergoing monopolar ablation (group 1, n=68) and those undergoing bipolar ablation (group 2, n=99). All patients were followed by electrocardiogram and 24-h Holter monitoring. Echocardiography was performed before discharge, at three and 12 months postoperatively, and annually thereafter. Left atrial volume index, left atrial diameter, and left ventricular ejection fraction were recorded.
Results: There was no significant correlation between the procedure applied and hypertension, hyperlipidemia, diabetes mellitus, chronic obstructive pulmonary disease, history of the cerebrovascular events (p>0.05). The mean preoperative left atrial diameter decreased from 5.3±0.5 cm to 4.9±0.5 cm postoperatively in all patients (p=0.0001). The mean preoperative left atrial volume index decreased from 53.8±0.4 mL/m2 t o 43.7±6.2 m L/m2 i n t he postoperative period (p=0.0001). During follow-up, 61.8% (n=42) of the patients in group 1 and 62.6% (n=62) of the patients in group 2 remained in sinus rhythm. One patient (1.5%) in group 1 and two patients (2.0%) in group 2 developed early postoperative cerebrovascular accident.
Conclusion: Monopolar and bipolar ablation methods are safe and effective methods to ensure long-term sinus rhythm. Both procedures do not increase the morbidity risk with very low thromboembolic complication rates.
In the present study, we aimed to evaluate the long-term outcomes of monopolar or bipolar RF ablation concomitant to mitral valve surgery in patients with AF.
All patients were followed by electrocardiography (ECG) and 24-h Holter monitoring before discharge and at one, three, six, and 12 months postoperatively and annually thereafter. Echocardiography was also performed before discharge and at three and 12 months and annually after surgery. The left atrial volume index (LAVI), LA diameter, and left ventricular ejection fraction (LVEF) were also recorded. All operations were performed by a single cardiovascular surgery team. Type of AF was determined according to the Heart Rhythm Society guidelines.
Monopolar RF ablation system
The Medtronic Cardioblade™ (Cardioblade,
Medtronic Inc., MN, USA) ablation system was used
for monopolar RF ablation. Operations were performed
through median sternotomy under cardiopulmonary
bypass (CPB). Systemic mild hypothermia was also
applied and the patients were cooled to 32°C after
the beginning of bypass. Myocardial protection was
achieved by delivering intermittent antegrade blood
cardioplegia. Radiofrequency lesions were created
in an endocardial manner and the ablation lines are
described in Figure 1. During the procedure, the
pen is slowly oscillated over the tissue. The power
generator can produce a power output ranging from
20 to 30 Watts/5 mL irrigation/min. The heart was
arrested and the left atriotomy was performed, and
a semicircular ablation line in the endocardium
was performed to isolate the right pulmonary veins.
Two lines around the left pulmonary veins were
made. Both encircling lesions were connected with
an ablation line in the posterior wall of the LA.
A connecting line from the atriotomy to the mitral
valve annulus was performed.
Bipolar RF ablation system
The Medtronic Cardioblate™ (Cardioblate,
Medtronic Inc., MN, USA) bipolar ablation system,
which consists of a power generator and an ablation
clamp, was used for bipolar RF ablation. Irrigation was
applied between the clamp and the tissue surface to cool
the tissue and maintain the tissue temperature between
45 and 55°C. The bipolar device was clamped around
the atrial cuff containing the right pulmonary veins.
During CPB before cross-clamping, the right pulmonary veins were encircled and ablated and the heart was, then, lifted and the left pulmonary veins were ablated. Both pulmonary vein ablations were repeated twice to avoid gaps. The LA was opened on cardioplegic arrest and an additional ablation line connecting both pulmonary isolation lines was performed. Another lesion was created from the left atriotomy lesion toward to P2-P3 leaflet of mitral valve by bipolar clamp (Figure 1). In all patients, we plicated the LA appendage.
Postoperative medical treatment
Intravenous amiodarone administration
was initiated before the end of CPB at a dose of
300 mg and continued for 24 hat a dose of 500 to
900 mg/24 h depending on the frequency. On the
second postoperative day, amiodarone 200 mg and
metoprolol 50 mg per oral were prescribed until the
third month postoperatively. In case of bradycardia
or atrioventricular block, amiodarone was avoided.
Warfarin was started on the postoperative first day
and was discontinued after three months, when sinus
rhythm was documented. In case of recurrent AF,
we continued lifelong warfarin. Cardioversion was
utilized in cases of early AF after surgery. Atrial and
ventricular temporary epicardial wires were applied to
all patients.
Statistical analysis
Statistical analysis was performed using the IBM
SPSS version 21.0 software (IBM Corp., Armonk, NY, USA). Descriptive data were expressed in mean
± standard deviation (SD) or number and frequency.
The Wilcoxon Z signed-rank test was used for the
intra-group comparisons, while the Mann-Whitney
U test was used to analyze significant differences
between the groups. The Kaplan-Meier curves were
used to estimate survival. A p value of < 0.05 was
considered statistically significant.
Table 1: Demographic and clinical characteristics of patient groups
Table 2: Comorbidities of patients
The mean duration of the CPB was 142.8 min in group 1 and 132.0 min in group 2 (p=0.0001). Persistent AF was observed in 60 patients (88.1%) in group 1 and 85 patients (85.8%) in group 2. Longstanding AF was detected in eight patients (11.9%) in group 1 and 14 patients (14.2%) in group 2. Early AF occurred during hospital stay before discharge; four (5.8%) in group 1 and seven (6.9%) in group 2. No significant relationship was found between the time of AF and surgery (p=0.440). At one-year follow-up, two patients in group 1 and three patients in group 2 had still AF; therefore, we considered failure of procedure in these patients. One patient (1.5%) in group 1 and two patients (2.0%) in group 2 developed early postoperative cerebrovascular accident. Early postoperative pulmonary embolism was diagnosed in one patient (1.5%) in group 1 and two patients (2.0%) in group 2 (p=0.638).
In all groups, the mean preoperative LA diameter decreased from 5.3±0.5 cm to 4.9±0.5 cm in the postoperative period, indicating a statistically significant difference (p=0.0001). In addition, the mean LAVI, which was 53.8±0.4 mL/m2 in the preoperative period, decreased to 43.7±6.2 mL/m2 in the postoperative period in all patients (n=167), indicating a statistically significant difference (Table 3, p=0.0001).
Table 3: Left atrial diameter and left atrial volume index measurements in overall patients
In group 1, the mean preoperative LA diameter decreased from 5.3±0.4 cm to 4.8±0.5 cm in the postoperative period, indicating a statistically significant difference (Figure 2, p=0.0001). In addition, the mean preoperative LAVI was 53.5±4.2 mL/m2 and the mean postoperative LAVI was 43.6±6.5 mL/m2, indicating a statistically significant difference (Figure 3, Table 4, p=0.0001).
Figure 2: Changes in pre- and postoperative left atrial diameter.
LA: Left atrium.
Table 4: Left atrial diameter and left atrial volume index measurements in Group 1
In group 2, the mean preoperative LA diameter (5.3±0.5 cm) showed a decrease and became 4.9±0.6 cm in the postoperative period with a statistically significant difference (p=0.0001). Similarly, in group 2, the mean preoperative LAVI was 54.0±4.5 mL/m2 and the mean postoperative LAVI was 43.8±6.0 mL/m2, indicating a statistically significant difference (Table 5, p=0.0001).
Table 5: Left atrial diameter and left atrial volume index measurements in Group 2
During the long-term follow-up, two patients from each group required permanent pacemaker implantation due to atrioventricular block. Also, in the long-term follow-up, seven patients in both groups had a transient ischemic attack without any neurological sequelae.
No significant correlation was found between the mortality and procedure type during long-term follow-up (Figure 4). Late mortality was observed in 13 patients (19.1%) (n=7 cardiac, n=1 unspecified, and n=5 non-cardiac) in group 1 and 23 patients (23.2%) (n=13 cardiac, n=3, and n=7 non-cardiac) in group 2 (p=0.331). We found no statistically significant relationship between sinus rhythm and the operation type during long-term follow-up. In group 1, 61.8% patients (n=42) remained in sinus rhythm after a mean follow-up of 11.4±2.3 years, while 62.6% patients (n=62) maintained sinus rhythm after a mean follow-up of 11.2±2.6 years in group 2. Furthermore, there was no statistically significant difference in the survival rates between the groups (p>0.05).
Grigioni et al.[6] reported that the risk for AF development was about 15 to 21% over five years, if conservative treatment was used to manage patients with functional mitral valve disease and was 42 to 54% of the patients developed AF at 10 years. Moreover, AF was associated with a high risk for cardiac death or heart failure with the risk of AF increasing with age and LA size.
It is obvious that, by restoring the sinus rhythm, both the risk of thromboembolism and the need for oral anticoagulation may be reduced.[7] Furthermore, sudden cardiac death or heart failure may be prevented. In addition, AF has been shown to be an independent significant predictor for long-term mortality.[8]
Approximately 40 to 50% of patients undergoing mitral valve surgery have a remarkable history of AF.[9] These patients usually remain in AF with low rates of conversion to sinus rhythm following a successful mitral valve surgery, if a surgical ablation procedure is not performed.[10] The potential benefits as well as the safety and efficacy of a surgical ablation procedure for AF during mitral valve operations are well-documented in the literature.[11]
Our results are comparable to several other reports published. Bogachev-Prokophiev et al.[12] included 47 patients who underwent bipolar left-sided ablation procedure with either mitral valve repair or replacement (n=47) and monitored the patients by a subcutaneous continuous monitoring system. At 12 months, the authors found that 65.2% of the patients (n=30) had no AF and 6.5% of the patients (n=3) experienced atrial flutter. The effect of preoperative AF in patients undergoing mitral valve surgery was also studied by Ngaage et al.[13] who reported that preoperative AF was associated with increased morbidity and decreased survival, if left uncorrected.
The goal of bipolar ablation is the isolation of triggering focus of AF episodes from the conduction system. Success rates for restoring sinus rhythm of AF patients with the bipolar RF ablation procedure ranged from 54 to 90%.[14] In this study, the mean follow-up duration of group 1 was 11.4±2.3 years and the rate of sinus rhythm was 61.8%. In addition, the mean follow-up duration of group 2 was 11.2±2.6 years with a rate of 62.6% sinus rhythm. Achieving a transmural and continuous lesion is critical for the procedural success. The main drawback with the monopolar system is the uncertainty in achieving a transmural lesion. Therefore, one can expect superior outcomes with the bipolar system theoretically, although this was not the case in our study.
In their study, La Meir et al.[15] showed that only patients who underwent the bilateral approach showed a significant improvement in the LA function and a significant reduction in the LA dimensions and LAVI. In our study, in both groups, the mean preoperative LA diameter decreased from 5.3±0.5 cm to 4.9±0.5 cm in the postoperative period. Also, the mean LAVI, which was 53.8±0.4 mL/m2 in the preoperative period, decreased to 43.7±6.2 mL/m2 in the postoperative period.
The main cause of early AF recurrence may be a transient stimulatory effect of inflammatory factor after the damage of histopathological tissue caused by ablation, electrical conduction between the LA and pulmonary veins reconnection, and transient imbalance of the autonomic nervous system.[16] Based on our experience, 16.2% patients (n=11) in group 1 and 14.1% patients (n=14) in group 2 had AF during the early postoperative period. We believe that patients experiencing no early AF recurrence are more likely to be away from late AF recurrence. Similarly, early AF recurrence has been demonstrated to be an independent risk factor for late AF recurrence.[17]
The need for early postoperative pacemaker after surgical procedures has been reported as ranging from 6 to 23%,[18] depending on the lesion pattern chosen or energy source applied. It has been suggested that the patients whose preoperative LA diameter is large and who are in sinus rhythm are more likely to need a permanent pacemaker. In our study, we performed pacemaker implantation in two patients in either group, although there was no statistically significant difference between the groups.
In another study, Scherer et al.[19] concluded that LA size reduction after RF ablation contributed to a higher restoration of sinus rhythm (70%) throughout a three-year follow-up period. In our study, the LA size reduction from 69±19 mm to 51±8 mm caused a decrease in late thromboembolic complications. In addition, we plicated the LA appendage in all patients to prevent possible thromboembolic events.
Nonetheless, there are some limitations to this study. First, this study has a retrospective design and a further prospective study is still ongoing. Second, the sample size is relatively small. Finally, creating additional lesions to bond the isolation circles over the ablation lines would further increase the success rate of the technique in patients undergoing bipolar RF ablation.
In conclusion, both monopolar and bipolar radiofrequency ablation methods do not cause any additional complication in either short-term or longterm follow-up and are safe and effective methods to ensure long-term sinus rhythm. Both procedures are also associated with low morbidity risk and thromboembolic complication rates.
Declaration of conflicting interests
The authors declared no conflicts of interest with respect to
the authorship and/or publication of this article.
Funding
The authors received no financial support for the research
and/or authorship of this article.
1) Sherman DG, Kim SG, Boop BS, Corley SD, Dimarco JP,
Hart RG, et al. Occurrence and characteristics of stroke
events in the Atrial Fibrillation Follow-up Investigation of
Sinus Rhythm Management (AFFIRM) study. Arch Intern
Med 2005;165:1185-91.
2) Cox JL. The surgical treatment of atrial fibrillation.
IV. Surgical technique. J Thorac Cardiovasc Surg
1991;101:584-92.
3) Cox JL, Canavan TE, Schuessler RB, Cain ME, Lindsay BD,
Stone C, et al. The surgical treatment of atrial fibrillation. II.
Intraoperative electrophysiologic mapping and description
of the electrophysiologic basis of atrial flutter and atrial
fibrillation. J Thorac Cardiovasc Surg 1991;101:406-26.
4) Cox JL, Schuessler RB, D"Agostino HJ Jr, Stone CM,
Chang BC, Cain ME, et al. The surgical treatment of
atrial fibrillation. III. Development of a definitive surgical
procedure. J Thorac Cardiovasc Surg 1991;101:569-83.
5) Chiappini B, Martìn-Suàrez S, LoForte A,
Di Bartolomeo R, Marinelli G. Surgery for atrial fibrillation
using radiofrequency catheter ablation. J Thorac Cardiovasc
Surg 2003;126:1788-91.
6) Grigioni F, Avierinos JF, Ling LH, Scott CG, Bailey KR,
Tajik AJ, et al. Atrial fibrillation complicating the course
of degenerative mitral regurgitation: determinants and longterm
outcome. J Am Coll Cardiol 2002;40:84-92.
7) Gillinov AM, McCarthy PM, Blackstone EH, Rajeswaran
J, Pettersson G, Sabik JF, et al. Surgical ablation of atrial
fibrillation with bipolar radiofrequency as the primary
modality. J Thorac Cardiovasc Surg 2005;129:1322-9.
8) Wang B, Xu ZY, Han L, Zhang GX, Lu FL, Song ZG.
Impact of preoperative atrial fibrillation on mortality
and cardiovascular outcomes of mechanical mitral valve
replacement for rheumatic mitral valve disease. Eur J
Cardiothorac Surg 2013;43:513-9.
9) Iung B, Vahanian A. Epidemiology of valvular heart disease
in the adult. Nat Rev Cardiol 2011;8:162-72.
10) Ad N, Cox JL. Combined mitral valve surgery and the Maze
III procedure. Semin Thorac Cardiovasc Surg 2002;14:206-9.
11) Pison L, Vroomen M, Crijns HJ. Surgical ablation for atrial
fibrillation. N Engl J Med 2015;373:483.
12) Bogachev-Prokophiev A, Zheleznev S, Romanov A,
Pokushalov E, Pivkin A, Corbucci G, et al. Ablation for
atrial fibrillation during mitral valve surgery: 1-year results
through continuous subcutaneous monitoring. Interact
Cardiovasc Thorac Surg 2012;15:37-41.
13) Ngaage DL, Schaff HV, Mullany CJ, Barnes S, Dearani JA,
Daly RC, et al. Influence of preoperative atrial fibrillation on
late results of mitral repair: is concomitant ablation justified?
Ann Thorac Surg 2007;84:434-42.
14) Chen L, Xiao Y, Ma R, Chen B, Hao J, Qin C, et al. Bipolar
radiofrequency ablation is useful for treating atrial fibrillation
combined with heart valve diseases. BMC Surg 2014;14:32.
15) La Meir M, Gelsomino S, Lucà F, Lorusso R, Gensini GF,
Pison L, et al. Minimally invasive thoracoscopic hybrid
treatment of lone atrial fibrillation: early results of monopolar
versus bipolar radiofrequency source. Interact Cardiovasc
Thorac Surg 2012;14:445-50.
16) Cai L, Yin Y, Ling Z, Su L, Liu Z, Wu J, et al. Predictors of
late recurrence of atrial fibrillation after catheter ablation. Int
J Cardiol 2013;164:82-7.
17) Arya A, Hindricks G, Sommer P, Huo Y, Bollmann A, Gaspar
T, et al. Long-term results and the predictors of outcome of
catheter ablation of atrial fibrillation using steerable sheath
catheter navigation after single procedure in 674 patients.
Europace 2010;12:173-80.