Herein, we present a case of ATT due to an endovascular aneurysm repair (EVAR) procedure which was performed two years ago.
Subsequent recurrent thrombosis of the left limb of the graft required several embolectomy procedures. However, during the third year of follow-up, chronic ischemic signs and rest pain appeared on the left lower limb. Thus, for the limb salvage of the left lower limb and for superior long-term patency for the right lower limb, we performed an aortabifemoral bypass via a transperitoneal approach. There was no adequate infrarenal neck for aortic cross-clamping due to the nitinol wires extending approximately the suprarenal level. Therefore, we placed the aortic cross-clamp on the thoracic aorta. Following clamping, the aneurysmatic sac of the aorta was incised vertically. The debris materials and organized thrombi were removed. The wires were cut with the wire scissors without destroying the aortic wall (Figure 2a). The free-ended wires were stabilized with sutures and surrounded by Teflon felt to avoid the damage to the peripheral tissues. Aortobifemoral bypass was performed using a 16/8-mm Dacron Y graft (MAQUET Intervascular, Cedex, France) (Figure 2b).
At the end of the operation, the femoral, popliteal, and posterior tibial arterial pulses were palpable with an ABI of 1.0. At 24 months of follow-up after the aortobifemoral bypass, the physical examination revealed palpable pulses of the lower limb arteries and no graft failure was observed. A written informed consent was obtained from the patient.
Although EVAR is a less invasive treatment alternative to open surgery, it is not free of complications and still may result in severe morbidity and mortality.[3] Early and late graft failures may lead to primary or secondary conversion to open repair. Endoleaks are the main reason for primary and secondary interventions.[4,5] Also, limb occlusion is the most common complication among the ischemic complications due to the kinking of the limb, and migration or the dislocation of an endograft component.[3] However, AAT due to EVAR, as in our case, is very rare.
Mantas et al.[6] defined many anatomic characteristics and predictors of limb occlusion for EVAR treatment. The CTA imaging of our patient revealed that a severely angulated proximal neck of the aorta and calcification and kinking of the iliac arteries which were already unfavorable characteristics for an EVAR treatment. It is evident that the preoperative CTA imaging should be evaluated very carefully when EVAR is considered. The most optimal endovascular device system for the patient is also important.
The proximal aortic clamping sites for abdominal aortic surgery are infrarenal, suprarenal, supraceliac, and thoracic levels.[7,8] Infrarenal and suprarenal clamping remained unfeasible in our case, as the nitinol wires were extending to the suprarenal level. Perini et al.[9] used infrarenal clamping for late open conversion after EVAR for grafts with suprarenal fixation in their center with satisfactory results. However, none of them were aortic thromboses. The aortic neck for proximal anastomosis was limited in our case, due to the occluded aorta, and to maintain an adequate proximal aortic flow, we preferred the upper level for clamping. If supraceliac clamping had been preferred in our case, our attempt would be to avoid any hazardous complication related to bowel injury, due to the tissue adhesions as a result of the inflammatory effects of the stent graft and aortic thrombosis. Thus, we preferred the thoracic level for cross-clamping, which is suggested as a proximal clamping method for AAA surgery in the literature, as long as the clamping duration is brief.[7]
In patients at a high operative risk, an extraanatomic bypass such as axillofemoral bypass is used as an alternative arterial reconstructive procedure. Urgent late open conversions after failed EVAR are associated with poor long-term survival rates.[8] Also, elective late open conversion after failed EVAR seem to be associated with improved outcomes than urgent conditions.[10] Since our patient was admitted with a mild acidosis due to the ischemic status, we decided to perform an extra-anatomic bypass as the first-choice for recovering the ischemic signs rapidly and providing survival. Nevertheless, an aortofemoral bypass has excellent r esults for long-term.[11]
In conclusion, patients should be evaluated individually for the treatment of AAA, and the anatomic criteria recommended for EVAR treatment should be well-defined for the patients to avoid catastrophic results. Unfavorable aortic anatomy is an important limitation for EVAR treatment. We believe that following the recommendations for anatomic criteria can reduce the number of late interventions, as well as the severity of late complications which are associated with high mortality and morbidity rates in the treatment of AAAs. Extra-anatomic bypass procedures should be kept in mind in urgent conditions for limb salvage. It should also be noted that the long-term patency rates of extra-anatomic bypass procedures are not excellent, whereas aortobifemoral bypass surgery is a conventional gold-standard treatment modality which yields excellent long-term patency rates.
Declaration of conflicting interests
The authors declared no conflicts of interest with respect to
the authorship and/or publication of this article.
Funding
The authors received no financial support for the research
and/or authorship of this article.
1) Surowiec SM, Isiklar H, Sreeram S, Weiss VJ, Lumsden
AB. Acute occlusion of the abdominal aorta. Am J Surg
1998;176:193-7.
2) Paravastu SC, Jayarajasingam R, Cottam R, Palfreyman
SJ, Michaels JA, Thomas SM. Endovascular repair of
abdominal aortic aneurysm. Cochrane Database Syst Rev
2014;1:CD004178.
3) Maleux G, Koolen M, Heye S. Complications after
endovascular aneurysm repair. Semin Intervent Radiol
2009;26:3-9.
4) Oğuz E, Posacıoğlu H, Parıldar M, Apaydın A. Partial
removal of endovascular stent grafts: technical considerations
in three cases. Turk Gogus Kalp Dama 2013;21:1074-8.
5) Parildar M, Posacioglu H. Endoleaks after endovascular
aortic aneurysm repair: definition and treatment. Turk Gogus
Kalp Dama 2011;19 Suppl 2:46-50.
6) Mantas GK, Antonopoulos CN, Sfyroeras GS, Moulakakis
KG, Kakisis JD, Mylonas SN, et al. Factors predisposing to
endograft limb occlusion after endovascular aortic repair.
Eur J Vasc Endovasc Surg 2015;49:39-44.
7) Büket S, Atay Y, Islamoğlu F, Yağdi T, Posacioğlu H, Alat I,
et al. Proximal clamping levels in abdominal aortic aneurysm
surgery. Tex Heart Inst J 1999;26:264-8.
8) Perini P, Gargiulo M, Silingardi R, Piccinini E, Capelli P,
Fontana A, et al. Late open conversions after endovascular
abdominal aneurysm repair in an urgent setting. J Vasc Surg
2019;69:423-31.
9) Perini P, de Troia A, Tecchio T, Azzarone M, Bianchini
Massoni C, Salcuni P, et al. Infrarenal endograft clamping