Methods:Nine patients (3 men and 6 women aging between 22 and 50 years) were operated for mitral valve replacement and left atrial volume reduction between 2001 and 2003. We used three surgical techniques for the reduction of the giant left atrium (1- Posterior paraannular plication, 2- Posterior wall plication, 3- Wall resection), and outcome of patients were evaluated.
Results:There was no early mortality. Postextubation period was uneventful in all patient. No patient needed reintubation. Preoperative mean left atrial size (7.92 ± 1.6 cm.) was reduced to mean 5.12 ± 0.95 cm, postoperatively. Left ventricle ejection fraction rate improved from 54.22% ± 6.87% to 55.44% ± 6.28% in postoperative first week.
Conclusions: The combined atrial reduction procedures showed marked decrease in the incidence of low output syndrome and respiratory failure postoperatively. We conclude that plication and wall resection procedures are effective techniques for the treatment of compression in the presence of giant left atrium.
Although many surgical procedures have been proposed to reduce the size of the left atrium, their effectiveness is not well established. But, only one surgical technique has been used in previous studies for the left atrial volume reduction. We have combined these surgical techniques and aimed to provide effective reduction in the left atrial size. In this report we describe our surgical techniques used for giant left atrium reduction in nine consecutive patients with rheumatic mitral valve disease and the outcome of patients.
Table 1: Patients characteristics.
Table 2: Echocardiographic measurements.
Surgical Technique
All operations were performed through a median sternotomy using cardiopulmonary bypass with moderate systemic hypothermia. Cardiopulmonary bypass was instituted using an arterial cannula in the ascending aorta and bicaval angled venous canulas in the right atrium. Myocardial protection was achieved by multidose infusions of antegrade cold blood cardioplegia. Seven mitral valve replacement and two mitral and aortic valve replacements were performed using St. Jude Medical prostheses.
Three different surgical techniques were performed for reduction of the giant left atrium (Figure1): 1- Posterior paraannular plication (a), 2- Posterior wall plication (b), 3- Wall resection (c). In the posterior paraannular plication, starting from the upper corner of the left atrial appendix, posteroinferior atrial wall was plicated with 4-0 continuous polypropylene sutures so as to be the left atrial appendix stayed into suture line. The suture was passed the 1 cm away from the posterior mitral annulus and 2 cm from the pulmonary veins. In the second technique, atrial wall between the left and right pulmonary veins was plicated with 4-0 continuous polypropylene sutures. Posterior paraannular plication and posterior wall plication were used in all patients. Last technique, that was wall resection, was used in only four patients additional to above two techniques, who had the largest atrial size. In this group of patients, triangular segment of left atrium with the base on the posterior portion of the atriotomy and the apex towards the outlet of the pulmonary veins was removed. The incision in the left atrium wall was repaired with a continuous suture of prolene 4/0. The left atriotomy was repaired as usual, removing simultaneously a large strip of the reflection of the left atrium into the interatrial septum.
Mean follow up was 18 months. There was no late mortality. Only one patient was referred to emergency service for dyspnea and tachycardia on second postoperative month. Echocardiographic examination revealed pericardial effusion in this patient, and pericardiocentesis was performed without any problem. All patients were in NYHA class I/II, at the end of the first year of operation.
The plication procedure result in a significant decrease in the incidence of low-output syndrome and respiratory failure postoperatively, as well as a marked decrease in mortality, reported in previous studies [1,2]. Some controversial studies show mitral valve replacement that the giant left atrium is not a significant risk factor in MVR and does not affect early and late results as compared with patients without the giant left atrium, and atrial plication may not be required in absence of extra cardiac signs of compression [3].
In our study preoperative mean left atrial size reduced. The last value is less then 6 cm border. All patients postoperative respiratory weaning was uneventful. Isomura and associates [1] reported that the left atrial diameter measured by echocardiogram was a mean of 7.3 ± 1 cm. before operation and 5.8 ± 1 cm postoperatively. Hagihara and associates [5] concluded that performing left atrial plication during mitral valve surgery was safe and effective for patients with the giant left atrium. They found that the left atrial diameter decreased significantly from 69 ± 8.5 mm to 53.7 ± 9.1 mm shortly after surgery, and this decreased was maintained even 5 years of surgery. In this two study (only one surgical technique used) atrial sizes were reduced mean 20% and 23% respectively. However, in our study atrial size reduced mean 35%.
Matsuda and associates [6] investigated the causes of prolonged postoperative respiratory support in mitral valve disease with and without a giant left atrium. They found that there was no significant difference between the two groups concerning the duration of postoperative respiratory care and the frequency of reintubation.
For many years, a lot of surgical techniques to reduce the left atrial volume in the giant left atrium have been performed. Wall plication (technique 1 and 2) is the most preference technique. However, this technique alone, sometimes results in insufficient left atrial reduction. Recently some new techniques as triangular resection [7] and partial autotransplantation [8] have been used to reduce the left atrial volume. Triangular resection is the same technique of our wall resection technique. We performed the wall resection in patients with largest atrial volume. Partial autotransplantation was not performed. This approach is aggressive and could increase morbidity and mortality. Since the left atrial size was between 6 and 9 cm we performed para-annular and posterior wall plication. If left atrial size had been above 9 cm; we would have been preferred to perform wall resection and wall plication together.
Another important point in this study was, postoperative atrial fibrillation note of. Chronic atrial fibrillation is frequently associated with mitral valve disease, especially when the left atrium is enlarged, which is the main determinant factor in the appearance and maintenance of chronic atrial fibrillation [9]. Atrial fibrillation is rare in the left atrium with a diameter of less than 40 mm [10]. Reduced atrial volume, surgical sutures in the atrial wall and atrial resection may be important factors in low atrial fibrillation rate.
The techniques of left atrial reduction proposed here are safe surgical techniques that can easily be performed. Its may be implemented in every patient to have the giant left atrium and undergone mitral valve surgery. The combined atrial reduction procedures showed marked decrease in the incidence of low output syndrome and respiratory failure postoperatively. We conclude that plication and wall resection procedures are effective method for the treatment of compression in the presence of giant left atrium secondary to rheumatic mitral valve disease.
1) Isomura T, Hisatomi K, Hirano A, Maruyama H, Kosuga K, Ohishi K. Left atrial plication and mitral valve replacement for giant left atrium accompanying mitral lesion. J Card
Surg 1993;8:365-70.
2) Kawozoe K, Beppu S, Kakahora V, Nakojime N. Surgical treatment of giant left atrium combined with mitral valvular disease. J Thorac Cardiovasc Surg 1983;85:885-92.
3) Di Eusanio G, Gregorini R, Mazzola A, et al. Giant left atrium and mitral valve replacement: Risk factor analysis. Eur J Cardiothorac Surg 1988;2:151-9.
4) Kawazoe K, Takahara Z, Tanaka K, et al. Giant left atrium in mitral valve disease: A new plication procedure to relieve the compressions of left ventricular wall left bronchus and right lung. Nippon Geka Gakkai Zasshi 1983;84:31-9.
5) Hagihara H, Kitamura S, Kawachi K, at al. Left atrial plication combined with mitral valve surgery in patients with a giant left atrium. Surg Today 1995;25:338-42.
6) Matsuda H, Nakao M, Nohara H, et al. The causes of prolonged postoperative respiratory care in mitral valve disease with a giant left atrium. Kyobu Geka 1990;43:172-7.
7) Sinatra R, Pulitani I, Antonazza A, Melina G. A novel technique for giant left atrium reduction. Eur J Cardiothorac Surg 2001;20:412-4.
8) Lessana A, Scorsin M, Scheuble C, Raffoul R, Rescigno G. Effective reduction of a giant left atrium by partial autotransplantation. Ann Thorac Surg 1999;67:1164-5.