Methods: A total of 42 patients (10 males, 32 females; mean age 51±14.6 years; range, 18 to 77 years) who underwent percutaneous dilatational tracheostomy procedure under extracorporeal membrane oxygenation and/or left ventricular assist device support between January 2017 and January 2019 were retrospectively analyzed. Laboratory data, Simplified Acute Physiology Score-II and Sequential Organ Failure Assessment scores, and major and minor complications were recorded. The 30-day and one-year follow-up outcomes of the patients were reviewed.
Results: Of 42 patients, 17 (42.5%), 14 (33.3%), and 11 (26.2%) received left ventricular assist device, extracorporeal membrane oxygenation, and extracorporeal membrane oxygenation + left ventricular assist device, respectively. During percutaneous dilatational tracheostomy, the laboratory values of the patients were as follows: international normalized ratio, 2.3±0.9; partial thromboplastin time, 59.4±19.5 sec; platelet count, 139.2±65.8×109/L, hemoglobin, 8.8±1.0 g/dL, and creatinine, 1.6±1.0 mg/dL. No peri-procedural mortality, major complication, or bleeding was observed. We observed minor complications including localized stomal ooze in four patients (8.3%) and local stomal infection in three patients (6.2%).
Conclusion: Our study results suggest that percutaneous dilatational tracheostomy is an effective and safe technique in this patient population.
In Turkey, our center is a specialized research hospital in cardiac and pulmonary surgery. Although our center has many years of experience in mechanical circulatory support application, including LVAD and ECMO, the implementation of percutaneous dilatational tracheostomy (PDT) in these patients has only increased in recent years due to safety concerns. The use of anticoagulants for the risk of thrombosis in patients undergoing mechanical circulatory support is the major safety concern due to the risk of major bleeding and/or other complications.[7,8]
In the literature, there is a limited number of data on the experience of the PDT procedure in patients receiving ECMO and/or LVAD support.[9-12] To the best of our knowledge, there is no study on the experience of PDT in patients receiving both LVAD and ECMO support. In this study, we aimed to investigate the efficacy and safety of the PDT procedure in patients receiving both LVAD and ECMO support.
Persistent LVAD support cannulas were used in the patients. The following systems for LVAD were used: The HeartMate II™ (Thoratec Corp., CA, USA; n=16); HeartMate 3™ (HM3, Abbott Inc., IL, USA, n=4); and HeartWare™ HVAD™ (HeartWare Inc., MA, USA; n=8). The ECMO circuit consisted of a Medos® oxygenator (Medos Medizintechnik, Stolberg, Germany) and a centrifugal pump. The LVAD and VA-ECMO were performed using the techniques mentioned in our previous studies.[13,14] Temporary right ventricular assist device (RVAD), intra-aortic balloon pump (IABP), and continuous veno-venous hemodialysis (CVVHD) performed according to the general condition of the patient were recorded during the peri-procedural period. The CentriMag™ (Levitronix LLC, MA, USA) RVAD was used.
Baseline demographic and clinical characteristics of the patients including age, sex, diagnosis, ejection fraction (EF) and Simplified Acute Physiology Score-II (SAPS-II) and Sequential Organ Failure Assessment (SOFA) scores and laboratory test results were recorded. The time duration of heparin cessation (≤4h before PDT) was defined as the pre-procedural time. The period encompassing 24 h before and after PDT was defined as the peri-procedural period. The amount of blood products used was recorded 24 h before and after PDT.
PDT anticoagulation and procedure
Patients undergoing LVAD support received
anticoagulation with heparin and warfarin. Once
the desired international normalized ratio (INR)
(?2) was achieved, heparin was discontinued and
anticoagulation was continued with warfarin
alone. The patients who received ECMO support
were anticoagulated with heparin. Heparin was
discontinued 4 h before the PDT procedure in
patients with ECMO. Heparin was continued after the
PDT procedure. The procedure was performed in all
patients with respiratory failure who required longterm
mechanical ventilation.
All procedures were performed at the bedside in the ICU. Patient preparation included premedication with sedative, midazolam (0.1 mg/kg), analgesic, fentanyl (2 µg/kg), and local infiltration of lidocaine 1%. A total of 100% oxygen was applied to the patient for 10 to 15 min immediately prior to the procedure to prevent intraoperative hypoxia. The PDT procedure was performed by two experienced bronchoscopists using Portex® G riggs™ forceps p ercutaneous d ilation tracheotomy kits (Portex Ltd., Hythe, Kent, UK). An endotracheal tube (ETT) and tracheal suctioning were done thoroughly with the aid of flexible fiberoptic bronchoscope (Pentax Ltd., Slough, UK). The ETT cuff was lowered and drawn back in such a way to remain immediately under the vocal cords. A 14-G intravenous cannula was moved between the second and third tracheal cartilage determined by palpation 1.5 to 2-cm below the cricoid, until air was inspired and the cannula entered the tracheal lumen. After placing the guidewire in the tracheal lumen, the cannula was withdrawn and expanded with an 8-F dilatator. The skin and trachea were enlarged with forceps. A No. 7 tracheostomy cannula was placed for female patients and a No. 8 tracheostomy cannula for male patients. The ETT withdrawal was done under the visual control of the bronchoscope. All steps were done by the visual control of the bronchoscope thus avoiding any structural injury (Video 1). The procedure was performed using the technique described in our previous studies.[15]
Major complications included procedurerelated death, cardiac arrest, hypotension requiring vasopressor therapy, acute hypoxemia, loss of airway, major bleeding (requiring open surgery or transfusion, or reducing hemoglobin levels by >20%), tracheal wall injury, false passage cannulation, pneumothorax, tracheostomy-related sepsis, and tracheostomy cannula obstruction. Minor complications included localized minor bleeding (localized stomal ooze or self-limiting bleeding), localized subcutaneous emphysema, shortterm desaturation, and local stomal infections.
Statistical analysis
Statistical analysis was performed using the
SSPS for Windows version 15.0 software (SPSS Inc.,
Chicago, IL, USA). All variables were analyzed for
normal distribution. Descriptive data were expressed
in mean and standard deviation (SD), median
(min-max) or number and frequency. Continuous
variables were compared using the Student's t-test
or the Mann-Whitney U test, where applicable. The
chi-square test was used to check proportions. A p
value of <0.05 was considered statistically significant.
Table 1: Baseline demographic and clinical characteristics of patients (n=42)
The peri-procedural laboratory data are shown in Table 2. The mean duration of PDT was 19±9.7 (range, 6 to 44) days after mechanical circulatory support. In the peri-procedural period, six patients (14.8%) underwent temporary IABP, four patients (9.5%) underwent temporary RVAD, and 10 patients (23.8%) underwent CVVHD. In the LVAD group, four patients (9.5%) with right heart failure had RVAD, six patients (14.8%) requiring positive inotropic support underwent IABP, and six patients (14.8%) with an increased creatinine level underwent CVVHD. The other four patients (9.5%) requiring CVVHD were in the ECMO group. In addition, there was no significant difference between the mechanical circulatory support in terms of hematological and coagulation parameters.
No peri-procedural mortality or major complications were observed in any of the patients. However, we observed minor complications including localized stomal ooze in four patients (8.3%) and local stomal infection in three patients (6.2%). During the procedure and follow-up, none of the patients required transfusion of erythrocytes, platelets, fresh frozen plasma, or other blood products. Mortality was observed in 18 patients (42.8%) after 30 days of follow-up. The causes of mortality were multiorgan failure in 10 (20.8%), sepsis in three (6.2%), and cardiac conditions (right ventricular failure) in five (10.4%) patients. In the first year of follow-up, additional 12 patients (25%) died (Table 3).
The 30-day and one-year follow-up outcomes according to the mechanical circulatory support techniques including LVAD, LVAD + ECMO and ECMO are summarized in Table 4. Accordingly, there was no significant difference in terms of outcome and follow-up data based on the mechanical circulatory support techniques used.
Table 4: Follow-up data according to the type of mechanical circulatory support
To date, a limited number of studies has shown that the PDT procedure is safe in patients with LVAD support. In a study including 31 patients, Gregoric et al.[23] observed no complication in the early (≤30 days) and late (>30 days) periods, except for minor complications. Pasin et al.[24] administered phenprocoumon, a coumarin derivative, to their patients and phenprocoumon was used together with heparin until the desired INR value was obtained. Although the mean INR and PTT in 36 patients were 2.1±0.9 and 68.9±19 sec, respectively, they did not observe any significant intra- or peri-procedural complications. In our study, the mean INR and PTT before the PDT procedure in patients with LVAD support were 2.4±0.9, 59.6±11.0 sec, respectively. No major complications, including major bleeding and death, were observed. Consistent with previous studies, our findings also support the safety of PDT in patients with LVAD.
The safety of the PDT procedure in patients receiving ECMO support has been demonstrated in very few studies. Braune et al.[11] showed that 68 patients (31.4%) who received ECMO support during PDT had minor bleeding, while 1.7% of them had major bleeding requiring surgical control or causing hypoxia. Kruit et al.[9] also performed PDT in 50 patients with ECMO support, and 40% of these patients had bleeding complications. Of these complications, 32% were minor bleeding and 8% were major bleeding. In our study, we performed PDT in 14 patients with ECMO support and did not observe any major complications or major bleeding. The third group in our study was the LVAD + ECMO support group who underwent PDT. We observed no major bleeding and complications.
The non-endothelial surface of the ECMO circuit causes the activation of clotting factors.[25,26] Therefore, anticoagulant therapy is very important for ECMO support. Current evidence suggests that the continuation of heparin administration during percutaneous tracheostomy is not associated with an increased risk of bleeding in the general ICU population.[22,24,27,28] In a recent study, Kruit et al.[9] found no significant difference in terms of bleeding risk between patients receiving and not receiving heparin during the PDT procedure. In our study, although the mean PTT during the procedure was 59.4±19.5 sec, we observed no major complications or bleeding. In previous studies, major bleeding was reported mostly in patients with platelet dysfunction and refractory coagulopathy.[25,26] Deppe et al.[27] found no major complications in 48 cardiothoracic patients with valve replacement who had a PTT of greater than 50 sec and continued heparin infusion. A systematic review reported that bleeding was associated with mechanical factors such as a low tracheal incision, prolonged intubation, malpositioned cannula tip, and the lack of bronchoscopic guidance during insertion.[29] Therefore, we believe that the incidence of bleeding may be increased due to technical and mechanical factors rather than hemostatic factors.
Nonetheless, there are some limitations to this study. First, the study is retrospective with a small sample size. Therefore, minor bleeding and complications may have been overlooked or underestimated due to the lower clinical relevance of the study. Second, there was no significant decrease in the platelet counts; however, further investigations evaluating platelet function were unable to be performed. Third, although the PTT of the patients was found to be favorable for anticoagulation during PDT, heparin was discontinued 4 h before the procedure, which can be deemed another limitation of the study. Implementation of the PDT procedure during ongoing heparin infusion may be the subject of further studies.
In conclusion, this is the first study to examine the percutaneous dilatational tracheostomy procedure in patients receiving both left ventricular assist device and extracorporeal membrane oxygenation support. Our study results suggest that percutaneous dilatational tracheostomy is an effective and safe technique in this patient population. However, further large-scale and long-term, prospective studies are needed to confirm these findings.
Declaration of conflicting interests
The authors declared no conflicts of interest with respect to
the authorship and/or publication of this article.
Funding
The authors received no financial support for the research
and/or authorship of this article.
1) Khush KK, Zaroff JG, Nguyen J, Menza R, Goldstein BA.
National decline in donor heart utilization with regional
variability: 1995-2010. Am J Transplant 2015;15:642-9.
2) Bernhardt AM, Reichenspurner H. High-risk donors:
extending our criteria in times of organ shortage. Curr Opin
Organ Transplant 2014;19:494-9.
3) Griffiths J, Barber VS, Morgan L, Young JD. Systematic
review and meta-analysis of studies of the timing of
tracheostomy in adult patients undergoing artificial
ventilation. BMJ 2005;330:1243.
4) Liu X, Wang HC, Xing YW, He YL, Zhang ZF, Wang T.
The effect of early and late tracheotomy on outcomes in
patients: a systematic review and cumulative meta-analysis.
Otolaryngol Head Neck Surg 2014;151:916-22.
5) Andriolo BN, Andriolo RB, Saconato H, Atallah
ÁN, Valente O. Early versus late tracheostomy for critically ill patients. Cochrane Database Syst Rev
2015;1:CD007271.
6) Longworth A, Veitch D, Gudibande S, Whitehouse T,
Snelson C, Veenith T. Tracheostomy in special groups of
critically ill patients: Who, when, and where? Indian J Crit
Care Med 2016;20:280-4.
7) Tarzia V, Buratto E, Bortolussi G, Gallo M, Bejko J, Bianco
R, et al. Hemorrhage and thrombosis with different LVAD
technologies: a matter of flow? Ann Cardiothorac Surg
2014;3:582-4.
8) Zangrillo A, Landoni G, Biondi-Zoccai G, Greco M, Greco
T, Frati G, et al. A meta-analysis of complications and
mortality of extracorporeal membrane oxygenation. Crit
Care Resusc 2013;15:172-8.
9) Kruit N, Valchanov K, Blaudszun G, Fowles JA, Vuylsteke
A. Bleeding Complications Associated With Percutaneous
Tracheostomy Insertion in Patients Supported With
Venovenous Extracorporeal Membrane Oxygen Support:
A 10-Year Institutional Experience. J Cardiothorac Vasc
Anesth 2018;32:1162-6.
10) Schwartz SP, Bonadonna D, Hartwig MG, Cheifetz IM.
Bedside Tracheostomy on Pediatric ICU Subjects Supported
by Extracorporeal Membrane Oxygenation. Respir Care
2017;62:1447-55.
11) Braune S, Kienast S, Hadem J, Wiesner O, Wichmann
D, Nierhaus A, et al. Safety of percutaneous dilatational
tracheostomy in patients on extracorporeal lung support.
Intensive Care Med 2013;39:1792-9.
12) Schaefer A, Schneeberger Y, Reichart D, Bernhardt AM,
Kubik M, Barten MJ, et al. Percutaneous Dilatation
Tracheostomy in Patients with Left Ventricular Assist
Device and Established Phenprocoumon Therapy. ASAIO J
2016;62:715-8.
13) Kervan U, Unal EU, Sert DE, Pac M. HeartWare Left
Ventricular Assist Device Implantation Combined with
Surgical Ventricular Reconstruction. Exp Clin Transplant
2019;17:278-80.
14) Kervan U, Kocabeyoglu SS, Sert DE, Aygün E, Kavasoglu K,
Karahan M, et al. A Novel Technique of Subclavian Artery
Cannulation for Venoarterial Extracorporeal Membrane
Oxygenation. Exp Clin Transplant 2017;15:658-63.
15) Turan S, Erdemli Ö, Ayik İ, Yavaş S, Yağar S, Bektaş Ş, et
al. Comparison of Percutaneous Tracheostomy Techniques:
Bronchoscopy Guided Versus Without Bronchoscopy.
Turkiye Klinikleri J Anest Reanim 2010;8:213-9.
16) Takahashi M, Itagaki S, Laskaris J, Filsoufi F, Reddy RC.
Percutaneous tracheostomy can be safely performed in
patients with uncorrected coagulopathy after cardiothoracic
surgery. Innovations (Phila) 2014;9:22-6.
17) Kornblith LZ, Burlew CC, Moore EE, Haenel JB, Kashuk
JL, Biffl WL, et al. One thousand bedside percutaneous
tracheostomies in the surgical intensive care unit: time to
change the gold standard. J Am Coll Surg 2011;212:163-70.
18) Delaney A, Bagshaw SM, Nalos M. Percutaneous dilatational
tracheostomy versus surgical tracheostomy in critically ill
patients: a systematic review and meta-analysis. Crit Care
2006;10:R55.
19) Al-Ansari MA, Hijazi MH. Clinical review: percutaneous
dilatational tracheostomy. Crit Care 2006;10:202.
20) Raimondi N, Vial MR, Calleja J, Quintero A, Cortés Alban
A, Celis E, et al. Evidence-based guides in tracheostomy use
in critical patients. Med Intensiva 2017;41:94-115.
21) Beiderlinden M, Eikermann M, Lehmann N, Adamzik M,
Peters J. Risk factors associated with bleeding during and
after percutaneous dilational tracheostomy. Anaesthesia
2007;62:342-6.
22) Al Dawood A, Haddad S, Arabi Y, Dabbagh O, Cook
DJ. The safety of percutaneous tracheostomy in patients
with coagulopathy or thrombocytopenia. Middle East J
Anaesthesiol 2007;19:37-49.
23) Gregoric ID, Harting MT, Kosir R, Patel VS, Ksela J,
Messner GN, et al. Percutaneous tracheostomy after
mechanical ventricular assist device implantation. J Heart
Lung Transplant 2005;24:1513-6.
24) Pasin L, Frati E, Cabrini L, Landoni G, Nardelli P, Bove T, et
al. Percutaneous tracheostomy in patients on anticoagulants.
Ann Card Anaesth 2015;18:329-34.
25) Esper SA, Levy JH, Waters JH, Welsby IJ. Extracorporeal
membrane oxygenation in the adult: a review of
anticoagulation monitoring and transfusion. Anesth Analg
2014;118:731-43.
26) Oliver WC. Anticoagulation and coagulation management
for ECMO. Semin Cardiothorac Vasc Anesth 2009;13:154-
75)
27) Deppe AC, Kuhn E, Scherner M, Slottosch I, Liakopoulos O,
Langebartels G, et al. Coagulation disorders do not increase
the risk for bleeding during percutaneous dilatational
tracheotomy. Thorac Cardiovasc Surg 2013;61:234-9.